Siemens 5SV3442-6 Datenblatt

Data sheet

5SV3442-6

Residual current operated circuit breaker, 4-pole, type A, In: 25 A, 100 mA, Un AC: 400 V

Model

product brand name

SENTRON

 

RCCB

product designation

 

Instantaneous

design of the product

 

 

General technical data

number of poles

size of installation devices / acc. to DIN 43880

mechanical service life (switching cycles) / typical

short-circuit current / of series fuse / maximum permissible

short-circuit current rating

switching function / short-term delayed

overvoltage category

4

1

10 000

80 A

10 kA

No

III

Supply voltage

operational current / at AC / rated value

25 A

 

230/400 V

● supply voltage / at AC / rated value

● supply voltage / for testing equipment /

100 V

minimum

 

 

 

5SV3442-6

12/10/2020

Subject to change without notice

Page 1/7

© Copyright Siemens

 

 

operating frequency

50 Hz

 

 

supply voltage frequency

 

 

 

● rated value

50 Hz

 

 

Protection class

protection class IP

IP20, if the distribution board is installed, with connected

 

conductors

 

 

 

 

Switching capacity

 

switching capacity current

acc. to EN 60898 / rated value

according to IEC 61008-1 / rated value

0.8 kA

0.8 kA

Dissipation

power loss [W]

for rated value of the current / at AC / in hot operating state / per pole

maximum

0.7 W

2.1 W

Current

tripping fault current / rated value

residual current type

let-through current / permissible

I2t value / permissible

surge current resistance / rated value

operational current

at 40 °C / rated value

at 45 °C / rated value

at 50 °C / rated value

at 55 °C / rated value

at 60 °C / rated value

at 65 °C / rated value

at 70 °C / rated value

100 mA

A

5 200 kA

58 000 A²·s

1 kA

25 A

25 A

25 A

25 A

25 A

23.3 A

17.62 A

Product details

product feature / silicon-free

Yes

 

 

product extension / installable / supplementary

Yes

devices

 

 

 

 

 

Connections

 

connectable conductor cross-section / solid

minimum

maximum

connectable conductor cross-section / stranded

minimum

maximum

0.75 mm²

35 mm²

0.75 mm²

35 mm²

5SV3442-6

12/10/2020

Subject to change without notice

Page 2/7

© Copyright Siemens

 

 

Siemens 5SV3442-6 Datenblatt

tightening torque / with screw-type terminals

minimum

maximum

position / of power supply cord

2.5 N·m

3 N·m

top or bottom

Mechanical Design

height

width

depth

installation depth

number of modular width units

fastening method

mounting position

net weight

90 mm

72 mm

70 mm

70 mm

4

DIN rail (REG)

any

350 g

Environmental conditions

ambient temperature / during operation

minimum

maximum

ambient temperature / during storage

minimum permissible

maximum permissible

number of test cycles / for environmental testing / acc. to IEC 60068-2-30

-25 °C

45 °C

-40 °C

75 °C

28

Certificates

 

reference code

 

 

 

● acc. to DIN EN 61346-2

F

 

● acc. to IEC 81346-2

F

 

 

 

 

 

 

 

 

General Product Approval

Miscellaneous

EMC

Declaration of

other

 

Railway

 

 

 

 

Conformity

 

 

 

 

 

 

 

 

 

 

Miscellaneous

 

Vibration and Shock

 

Confirmation

 

Further information

5SV3442-6

12/10/2020

Subject to change without notice

Page 3/7

© Copyright Siemens

 

 

Loading...
+ 4 hidden pages