Siemens 150 H, HG 1500 User Guide

Hicom 150 H HiPath HG 1500
V 2.0
Service Manual
*1PA31003-K5020-S100-6-7620*
1P A31003-K5020-S100-6-7620
Siemens AG 2001 Reference no.: A31003-K5020-S100-6-7620 Printed in the Federal Republic of Germany. Subject to availability. Right of modification reserved.
Hicom 150 H
Introduction
1
Installation
2
HiPath HG 1500
V 2.0
Service Manual
Startup
3
Administration
4
Additional information
5
-
6
A31003-K5020-S100-6-7620
--
7
--
8
--
9
--
10
lan2detoc.fm
For internal use only
Contents
Contents 0
1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1 HiPath HG 1500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.1.1 Prerequisite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.2 Short description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.3 Service information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1.4 Hicom password concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.5 Functional environment of HiPath HG 1500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1.5.1 Parallel operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1.5.2 Interworking with features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1.5.2.1 Least Cost Routing (LCR). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1.5.2.2 Trunk access/toll restriction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1.5.3 Gatekeeper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
2 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.1 HiPath HG 1500 boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1.1 HXGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1.1.1 HXGS V.24 interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.1.2 HXGM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
2.1.2.1 HXGM V.24 interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
2.1.3 Interfaces to the LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
2.2 Part numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
2.3 HiPath HG 1500 installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
2.3.1 Installation requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
2.3.2 Slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
2.3.3 Installation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15
3 Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
3.1 Initial startup of HiPath HG 1500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.1.1 Initial startup: Remote via modem. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.1.2 Startup via ARP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.1.3 Initial startup via the serial interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.2 Configuration for gatekeeper mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
3.2.1 Configuration HiPath HG 1500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
3.2.2 Configuring the NGK 100 gatekeeper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
4 Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
4.1 Tracing with development trace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.2 Determining the firmware version of the board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
5 Additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
5.1 Integrating various network topologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.1.1 Star topology with hub (10/100 BaseT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
A31003-K5020-S100-6-7620 Service Manual
0-1
lan2detoc.fm
Contents
For internal use only
5.1.2 Bus topology (10 Base2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.2 SW upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
5.3 Firmware Download . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
0-2
A31003-K5020-S100-6-7620
Service Manual
lan2delof.fm
For internal use only
Figures
Figures 0
Figure 2-1 HXGS interfaces (S30810-Q2931-X/X100). . . . . . . . . . . . . . . . . . . . . . . . 2-3
Figure 2-2 HXGS2 interfaces with 2nd LAN (S30810-Q2939-X000/X100) . . . . . . . . 2-3
Figure 2-3 HXGM interfaces (S30810-Q2930/Q2940-X/X100) . . . . . . . . . . . . . . . . . 2-7
Figure 2-4 Adapter for HXGM backplane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Figure 2-5 LAN adapter cable (U.S. only). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
Figure 3-1 Installation for gatekeeper mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Figure 5-1 10/100 BaseT cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Figure 5-2 10 Base2 cabling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
A31003-K5020-S100-6-7620 Service Manual
0-3
lan2delof.fm
Figures
For internal use only
0-4
A31003-K5020-S100-6-7620
Service Manual
lan2delot.fm
For internal use only
Tab le s
Tabl es 0
Table 1-1 Starting Hicom system administration (Service) . . . . . . . . . . . . . . . . . . . . 1-4
Table 2-1 HXGS application option/slot. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Table 2-2 HXGS hardware variants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Table 2-3 Contact assignment of the HXGS LAN interfaces. . . . . . . . . . . . . . . . . . . 2-4
Table 2-4 HXGS V.24 interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Table 2-5 HXGM application option/slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Table 2-6 HXGM hardware variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Table 2-7 RJ45 socket assignment (HXGM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Table 2-8 Assignment of the SIPAC-RJ45 LAN adapter. . . . . . . . . . . . . . . . . . . . . . 2-9
Table 2-9 Assignment of the CHAMP-RJ45 LAN adapter cable . . . . . . . . . . . . . . . 2-10
Table 2-10 HXGM LED concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Table 2-11 Contact assignment of the HXGM LAN interfaces . . . . . . . . . . . . . . . . . 2-11
Table 2-12 V.24 socket assignment (HXGM2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
Table 2-13 Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
Table 2-14 Installation procedure in the case of OfficePoint/Com . . . . . . . . . . . . . . 2-15
A31003-K5020-S100-6-7620 Service Manual
0-5
lan2delot.fm
Tab le s
For internal use only
0-6
A31003-K5020-S100-6-7620
Service Manual
lan2de.c01
For internal use only

1 Introduction

This service manual refers to HiPath HG 1500 V 1.0/V 2.0 as well as Hicom Xpress @LAN V1.1 with the LAN boards HXGS and HXGM.
HiPath HG 1500 supports the standard functions of ISDN (IP/IPX) routers together with the additional functionality of a voice gateway (H.323). A virtual CAPI interface (vCAPI) and a TAPI interface (CSTA) are also provided. The system also facilitates PC-supported telephony (CTI) and HiPath HG 1500 administration via a LAN PC.
Caution
7
All safety instructions for service and technical personnel given in the "Important In­formation" section of the Hicom 150 E Office/Hicom 150 H Service Manual are also applicable to HiPath HG 1500 and must be observed. Only authorized staff should work on the system.
Introduction
Note
Note that when configuring voice applications, only S30810-Q2930/Q2940-X (HXGM/HXGM2) and S30810-Q2931/Q2939-X (HXGS/HXGS2) boards may be used.

1.1 HiPath HG 1500

Hicom Xpress @LAN and HiPath HG 1500 create a bridge between the LAN and the ISDN network via an integrated HXGS/HXGM board
Suitable for:
Hicom 150 E Office Version 2.2 and later or Hicom 150 H V 1.0 or later, Office­Point/OfficeCom/OfficePro model
The following implementation scenarios are possible:
Voice gateway between LAN (H.323) and standard telephones (e.g. Netmeet­ing),
Telephoning from the PC (voice over IP) with Optiset features at the PC or via the Xpress client,
WAN connections via the ISDN network, including PPP Multilink,
Remote access from within company LANs (provided via analog V34, GSM V110 and ISDN),
Internet access (PPP router, NAT),
A31003-K5020-S100-6-7620 Service Manual
1-1
lan2de.c01
Introduction
vCAPI for client PCs including fax services and CTI,
SNMP (e.g. statistics and error signaling),
Routing via the xDSL network (for HXGS with 2nd LAN interface only).
Interfaces:
10/100BT Autosense Ethernet twisted-pair,
10BT Ethernet (for HXGS with 2nd LAN interface only) configurable with PPPoE,
Up to 16 B channels,
SLIP access (serial line interface) for initial startup, incl. cable (reference no. S30122-X5468-X3).

1.1.1 Prerequisite

For this application, TCP/IP is implemented as the transport protocol and Win95/98/ NT 4.0 or Windows 2000 as the client operating system. For the routing functionality, the IP/IPX protocols are transferred transparently, independent of the operating sys­tem. Call numbers are allocated in HiPath HG 1500 via TCP/IP Address > Call Num­ber (max. 100 call numbers for vCAPI and max. 48 stations for voice applications). The assignment of several call numbers to one TCP/IP address may be necessary if several services are to be configured (voice, fax, file transfer, etc.).
For internal use only

1.2 Short description

HiPath HG 1500 is an expansion card for Hicom 150 E Office/Hicom 150 H Point/ Com/Pro. It is used to connect a "local" LAN to Hicom systems and to link "external" LANs via the system’s ISDN interface. Telematics and CTI functions are also support­ed.
The connection to the "local" LAN is set up via an Ethernet twisted-pair interface (RJ45 connector); see Figure 2-1 and Figure 2-4. In the case of OfficePoint and Com, the connection to the system is set up via a 50­pin edge connector of an expansion slot. The connection to the LAN is set up via an RJ45 connector on the HiPath HG 1500 board. In the case of OfficePro, the board is connected to the system via the backplane. An adapter for the backplane (part number C39228-A7195-A10, US backplane: C39195­Z7404-A10) is used to connect the LAN with an RJ45 connector.
V.24 interface
For loading and administration purposes (SLIP access), each system is provided with an individual V.24 interface (cable reference no. S30122-X5468-X3). In both sys­tems, the V.24 connector for SLIP access is located on the board.
1-2
A31003-K5020-S100-6-7620
Service Manual
lan2de.c01
For internal use only

1.3 Service information

The unique worldwide Ethernet address (MAC address) is a factory default and can­not be modified.
Card recognition is performed automatically in Hicom 150 E Office/Hicom 150 H, Point/Com/Pro. HiPath HG 1500 is installed as an individual board type in Hicom 150 E Office/Hicom 150 H, Point/Com/Pro.
The following items can be administered in Hicom:
S0 station
Xpress clients
IP network lines
numbering scheme
associated dialing
Introduction
answer group (PC telephone)
call forwarding (PC to fax)
suppression of incoming 0
CSTA interface
Details on the initial startup and on accessing the board can be found in the HiPath HG 1500 Administration Manual. A separate tool (Assistant Xpress @LAN/HG 1500) that can also be used by the cus­tomer or the LAN administrator is provided for entering and modifying data, e.g. the IP address of the customer LAN or ISDN numbers assigned to a communication part­ner. The data is permanently stored in HiPath HG 1500. HiPath HG 1500 Assistant also facilitates the storage of a corresponding configuration file. This can then be re­trieved if a board needs replacing. The tool also provides a facility for querying the software version. Access to HiPath HG 1500 administration is password-protected. This password can be changed; however, the Hicom password concept applies; see
Ta b l e 1 - 1 .
Note that only the user and Hicom passwords are allowed.
A simple functional test can be performed directly at the customer PC or on a service PC with a network card, vCAPI driver and a CAPI-based application.
APS transfer for the HiPath HG 1500 board is usually performed via the LAN using the Assistant or, in exceptional circumstances, via the V.24 interface using the Load­er.
Cable with reference number S30122-X5468-X3 (see also Section 2.1.1.1 or
Section 2.1.2.1) is used for the V.24 port of the HiPath HG 1500 board.
A31003-K5020-S100-6-7620 Service Manual
1-3
lan2de.c01
Introduction

1.4 Hicom password concept

Table 1-1 Starting Hicom system administration (Service)
Step Input Explanation
1. *95 Start system administration
2. 31994 User: 31994 (default)
3. 31994 Password: 31994 (default)
1.
2. Confirm user and/or password
Further information is contained in the Hicom 150 E Office Rel. 2.0-3.0 Service Man­ual or Hicom 150 H V1.0.
For internal use only
or
Change user and/or password
1-4
A31003-K5020-S100-6-7620
Service Manual
lan2de.c01
For internal use only

1.5 Functional environment of HiPath HG 1500

1.5.1 Parallel operation

Hicom 150 E Office/Hicom 150 HCom/Pro systems support parallel operation of sev­eral HiPath HG 1500 boards.
System type Number of boards
OfficePoint 1 OfficeCom 2 OfficePro 3

1.5.2 Interworking with features

Introduction
1.5.2.1 Least Cost Routing (LCR)
In Hicom systems, LCR technology enables the most cost-effective connections via ISDN.
1.5.2.2 Trunk access/toll restriction
Trunk access is configured in Hicom 150 H/HiPath HG 1500Point/Com/Pro for call numbers used by Hicom 150 E Office. Hicom toll restriction for outgoing seizure is performed based on this trunk access in the same way as for outgoing calls.

1.5.3 Gatekeeper

The following functions are performed by a gatekeeper in an H.323 network:
Registering H.323 end units,
Managing rights and services,
Converting station numbers to logical names or IP addresses and vice versa,
Managing bandwidth on the network side,
Registering gateways,
Registering multiconference units,
Can be linked to neighboring gatekeepers (zones).
The setup procedure for gatekeeper operations is described in Section 3.1.3.
A31003-K5020-S100-6-7620 Service Manual
1-5
lan2de.c01
Introduction
If no gateways or multiconference units are being used, IP telephony can also be
>
implemented in H.323 networks without gatekeepers. Note, however, that the con­nection can only be set up via the IP address in this case, so no authorizations and bandwidth control are possible.
In general, the following applies: without gatekeepers, many features may be dis­abled or subject to severe restrictions.
For internal use only
1-6
A31003-K5020-S100-6-7620
Service Manual
s
lan2de.c02
For internal use only

2 Installation

2.1 HiPath HG 1500 boards

HG 1500 supports two function groups: the “voice functionality” with the features H.323 GW and TFA and the “data functionality” with the features VCAPI and RAS. A board variant (X100) that only supports the data functionality (Data only) is available; this board is not equipped with signal processors and the associated logic.

2.1.1 HXGS

Introduction
The HiPath HG 1500 board HXGS connects Hicom 150 E Office/Hicom 150 H Office­Com/OfficePoint with the LAN environment. The board supports up to 16 B channels.
The following board variants are available: HiPath HG 1500 HXGS Voice and Data (S30810-Q2931-X) HiPath HG 1500 HXGS Data only (S30810-Q2931-X100) HiPath HG 1500 HXGS2 Voice and Data 2nd LAN interface (S30810-Q2939-X000) HiPath HG 1500 HXGS2 Data only 2nd LAN interface (S30810-Q2939-X100)
Installation
HiPath HG 1500 board
Board slot
Table 2-1 HXGS application option/slot
Possible application Boards Slot
OfficePoint
OfficeCom Old HW CBFC
OfficeCom New HW CBPC
Hicom 150 E as of V 2.2
P30370-P722-A680-*
Hicom 150 H as of V 1.0
P30370-P802-A680-*
Hicom 150 H as of V 1.2
P30370-P822-A680-* Hicom 150 E as of V 2.2
P30370-P723-A680-G1
Hicom 150 E as of V 2.2
P30370-P721-A680-*
Hicom 150 H as of V 1.0
P30370-P801-A680-*
Hicom 150 H as of V 1.2
P30370-P821-A680-*
1 All slots
2 * Slots 4 and 5 only
2 * All slots
A31003-K5020-S100-6-7620 Service Manual
2-1
lan2de.c02
Installation
HiPath HG 1500 boards
Table 2-1 HXGS application option/slot
* = 2 boards may be operated in parallel OfficeCom, old HW, CBFC: S30810-Q2950-X OfficeCom, new HW, CBPC: S30810-Q2932-A201
Table 2-2 HXGS hardware variants
System type Services DSPs Board ID
OfficeCom/Point Data only 0 HXGS OfficeCom/Point Voice/Data 4 HXGS OfficeCom/Point Data only (2nd LAN) 0 HXGS2 OfficeCom/Point Voice/Data (2nd
For internal use only
Possible application Boards Slot
4 HXGS2
LAN)
2 simultaneous Voice over IP connections are possible for each DSP (Digital Signal Processor).
Interfaces/connectors
The LAN port is linked at the X3/X4 connectors. For connector assignment, see
Ta b l e 2 - 3 .
The board is equipped with a 50-pin edge connector to the system, two Western sockets (8-pin, 10-pin shielded) to the LAN and a shielded MiniDin socket (6-pin) for the V.24 interface:
X1: 50-pin to the system
X2: 6-pin shielded MiniDin socket for V.24 interface, see Section 2.1.1.1
The following connection option is provided for connection to a LAN:
X3: 8-pin Western socket for LAN 10/100 Base-T, RJ45 socket (twisted pair) for station
X4: 8-pin Western socket for LAN 10 Base-T, RJ45 socket (twisted pair) for trunk connection (
for HXGS2 board with 2nd LAN interface only
)
2-2
A31003-K5020-S100-6-7620
Service Manual
s
lan2de.c02
For internal use only
LAN connec­tion
Installation
HiPath HG 1500 board
HXGS
50
V. 2 4X2
X1
to CUC/
10/100 Base-TX3
CUP
2
Figure 2-1 HXGS interfaces (S30810-Q2931-X/X100)
HXGS2
with 2nd LAN interface
50
V. 2 4X2
LAN connec­tions
10 Base-T (trunk)X4
X1
to CUC/
10/100 Base-T (station)X3
CUP
2
Figure 2-2 HXGS2 interfaces with 2nd LAN (S30810-Q2939-X000/X100)
A twisted-pair cable is used as the transmission medium for 10/100 Base-T and 10 Base-T.
A31003-K5020-S100-6-7620 Service Manual
2-3
lan2de.c02
Installation
HiPath HG 1500 boards
The cable is connected to the HiPath HG 1500 HXGS/HXGS2 (OfficeCom and Offi­cePoint) via the 8-pin Western socket (X3) located on the MDF side of the circuit board, see Figure 2-1, or X3 and X4, see Figure 2-2.
Table 2-3 Contact assignment of the HXGS LAN interfaces
X3
10/100 Base-T
1 1 Transmit: + wire 2 2 Transmit: - wire 3 3 Receive: + wire 6 6 Receive: - wire
4+5+7+8 4+5+7+8 not used
X4
10 Base-T
For internal use only
Function
Notes
Direct Ethernet twisted-pair connection to HiPath HG 1500
The RJ45 cable must be crossed as follows:
1 <> 32 <> 63 <> 16 <> 2
A ferrite kit must be installed on the LAN 1 and LAN 2 lines on the RJ45 cable.
2.1.1.1 HXGS V.24 interface
The Serial Interface Cable (SIC, S30122-K5468-X3-*) can be connected via a 6-pin MiniDin socket on the front panel of the HXGS. The SIC performs level conversion from TTL signals (HXGS) to V.24 (9-pin Sub-D socket). Depending on the SIC, the maximum authorized transmission rate for the V.24 interface is 19.2 kBit/s. Asynchro­nous transmission only is supported.
The interface is used for administration purposes. It can be used for software updates or board configuration. It can also be used for software debugging.
2-4
A31003-K5020-S100-6-7620
Service Manual
s
lan2de.c02
For internal use only
Table 2-4 HXGS V.24 interface
Pin Signal I/O Function
1GND 2 TXD O Transmit Data 3 CTS I Clear to Send 4 RXD I Receive Data 5 RTS O Request to Send 6+5V
(7) GND
Installation
HiPath HG 1500 board
A31003-K5020-S100-6-7620 Service Manual
2-5
lan2de.c02
Installation
HiPath HG 1500 boards

2.1.2 HXGM

Introduction
The HiPath HG 1500 board HXGM connects the Hicom 150 H OfficePro with the LAN environment. The board supports up to 16 B channels.
The following board variants are available: HiPath HG 1500 HXGM Voice and Data (S30810-Q2930-X) HiPath HG 1500 HXGM Data only (S30810-Q2930-X100) HiPath HG 1500 HXGM2 Voice and Data 2nd LAN interface (S30810-Q2940-X000) HiPath HG 1500 HXGM2 Data only 2nd LAN interface (S30810-Q2940-X100)
Board slot
Table 2-5 HXGM application option/slot
For internal use only
Possible application Boards Slot
OfficePro
Hicom 150 E as of V 2.2
3 * All slots, except 2
P30370-P720-A680-*
Hicom 150 H as of V 1.0
P30370-P800-A680-*
Hicom 150 H as of V 1.2
P30370-P820-A680-*
* = Several boards may be operated in parallel
Table 2-6 HXGM hardware variants
System type Services DSPs Board ID
OfficePro Data only 0 HXGM OfficePro Voice/Data 8 HXGM OfficePro Data only (2nd LAN) 0 HXGM2 OfficePro Voice/Data (2nd
8 HXGM2
LAN)
2 simultaneous Voice over IP connections are possible for each DSP (Digital Signal Processor).
2-6
A31003-K5020-S100-6-7620
Service Manual
s
lan2de.c02
For internal use only
Interfaces/connectors
X10: 6-pin shielded MiniDin socket for V.24 cable; see Section 2.1.2.1
The board is connected to the system via the backplane. An adapter for the back­plane (part number C39228-A7195-A10, US backplane: C39195-Z7404-A10) is used to connect the LAN with an RJ45 connector, see Figure 2-4.
LED H2 (green)
LED H1 (red)
Installation
HiPath HG 1500 board
Backplane
HXGM/HXGM2
V. 2 4X10
*) LAN 2 - for HXGM board with 2nd LAN interface only
to BP
Adapter connection
LAN 2* X8
LAN 1 X9
Figure 2-3 HXGM interfaces (S30810-Q2930/Q2940-X/X100)
A31003-K5020-S100-6-7620 Service Manual
2-7
lan2de.c02
Installation
HiPath HG 1500 boards
Metal housing
For internal use only
RJ45 socket
Figure 2-4 Adapter for HXGM backplane
Table 2-7 RJ45 socket assignment (HXGM)
Pin Signal I/O Function
1 TDP O Transmit Data + 2 TDN O Transmit Data ­3 RDP I Receive Data + 4 (TT1) I Transmit Termination 1 5 (TT2) I Transmit Termination 2 6 RDN I Receive Data ­7 (RT1) I Receive Termination 1 8 (RT2) I Receive Termination 2
1SU-SIPAC connector
2-8
The TT1/2 and RT1/2 signals are not necessary for data transmission. They repre­sent a signal termination of 100 ohms (known as a Bob Smith Termination) for the two unused wire pairs in a four-pair twisted-pair cable.
A31003-K5020-S100-6-7620
Service Manual
s
lan2de.c02
For internal use only
Table 2-8 Assignment of the SIPAC-RJ45 LAN adapter
SIPAC connec-
Installation
HiPath HG 1500 board
RJ45 socket Signal
tor
B1 1 TDP C2 2 TDN B3 4 TT1 C4 5 TT2 B5 3 RDP C6 6 RDN B7 7 RT1 C8 8 RT2
LAN adapter cable (U.S. only)
Contact is established between the LAN and RJ45 via a CHAMP adapter cable. The adapter is connected to the CHAMP socket on the rear of the backplane which is assigned to the HG 1500 slot. Both the adapter cable and the connector are shielded.
female
male
Figure 2-5 LAN adapter cable (U.S. only)
A31003-K5020-S100-6-7620 Service Manual
10/100 Base-T
10 Base-T
2-9
lan2de.c02
Installation
HiPath HG 1500 boards
Table 2-9 Assignment of the CHAMP-RJ45 LAN adapter cable
CHAMP con-
nector
34 1 TDP LAN #2 35 2 TDN 36 4 TT1 37 5 TT2 38 3 RDP 39 6 RDN 40 7 RT1 41 8 RT2 42 1 TDP LAN #1
For internal use only
RJ45 socket Signal Ethernet
43 2 TDN 44 4 TT1 45 5 TT2 46 3 RDP 47 6 RDN 48 7 RT1 49 8 RT2
25, 50 Housing Shield
Table 2-10 HXGM LED concept
H1 - red H2 - green Meaning
Flashing Off Board is included in Firmware, no valid SW on board,
therefore V.24 charge mode
On Off Board is included in Firmware, e.g. following reset, re-
boot
On -> Off Off Board at SW start, reboot
2-10
Off Off -> On Board in idle status following reboot (call number of
logon router) Off On At least one B channel occupied On On Approx. 20 s long: Board ready to activate reset (e.g. fol-
lowing APS transfer or a FATAL error), waiting for Hicom
reset
A31003-K5020-S100-6-7620
Service Manual
s
lan2de.c02
For internal use only
Table 2-11 Contact assignment of the HXGM LAN interfaces
10/100 Base-T
Note
Direct Ethernet twisted-pair connection to HiPath HG 1500
The RJ45 cable must be crossed as follows:
HiPath HG 1500 board
X9 (LAN1)
X8 (LAN 2)
Function
10 Base-T
1 1 Transmit: + wire 2 2 Transmit: - wire 3 3 Receive: + wire 6 6 Receive: - wire
4+5+7+8 4+5+7+8 not used
Installation
1 <> 32 <> 63 <> 16 <> 2
2.1.2.1 HXGM V.24 interface
The Serial Interface Cable (SIC, S30122-K5468-X3-*) can be connected via a 6-pin MiniDin socket on the front panel of the HXGM. The SIC performs level conversion from TTL signals (HXGM2) to V.24 (9-pin Sub-D socket). Depending on the SIC, the maximum authorized transmission rate for the V.24 interface is 19.2 kBit/s. Asynchro­nous transmission only is supported.
The interface is used for administration purposes. It can be used for software updates or board configuration. It can also be used for software debugging.
Table 2-12 V.24 socket assignment (HXGM2)
Pin Signal I/O Function
1GND 2 TXD O Transmit Data 3 CTS I Clear to Send 4 RXD I Receive Data 5 RTS O Request to Send 6+5V
A31003-K5020-S100-6-7620 Service Manual
2-11
lan2de.c02
Installation
HiPath HG 1500 boards
Table 2-12 V.24 socket assignment (HXGM2)
Pin Signal I/O Function
(7) GND
Note
A SLIP connection is required for Assistant administration of Xpress @LAN/HG 1500. However, a SLIP connection is not possible for the Loader.

2.1.3 Interfaces to the LAN

The physical configuration of the LAN interface is predefined by the IEEE 802 stan­dard. The interface conforms to international standards for electrical safety and elec­tromagnetic compatibility (EMC). The electrically isolated coupling of the board at the LAN is performed by the send and receive transmitter. The maximum transmission speed of this "baseband" transmission technology is 100 MBit/s; the "Manchester" signaling code is used. The HiPath HG 1500 boards HXGS and HXGM are provided with a 10/100MB Au­tosense LAN port. The HiPath HG 1500 boards HXGS2 and HXGM2 with a 2nd LAN interface are also provided with a 10 BT LAN port, for example for routing via DSL.
For internal use only
2-12
A31003-K5020-S100-6-7620
Service Manual
s
lan2de.c02
For internal use only

2.2 Part numbers

HXGM Data only -- -- S30810-Q2930-X100 HXGM Voice and Data -- -- S30810-Q2930-X HXGM2 Data only -- -- S30810-Q2940-X100 HXGM2 Voice and Data -- -- S30810-Q2940-X000 HXGS Data only S30810-Q2931-X100 S30810-Q2931-X100 -­HXGS Voice and Data S30810-Q2931-X S30810-Q2931-X -­HXGS2 Data only with 2nd
LAN HXGS2 Voice and Data
with 2nd LAN Assistant Xpress @LAN
HG 1500
Installation
HiPath HG 1500 board
ID Part number
OfficePoint OfficeCom OfficePro
S30810-Q2939-X100 S30810-Q2939-X100 --
S30810-Q2939-X000 S30810-Q2939-X000 --
P30300-P1562-A1 P30300-P1562-A1 P30300-P1562-A1
Loader P30300-P1509-* P30300-P1509-* P30300-P1509-* CSTA converter P30300-P1530-A1 P30300-P1530-A1 P30300-P1530-A1 vCAPI (SW) P30300-P1561-A1 P30300-P1561-A1 P30300-P1561-A1 CTI TAPI 1P (4 clients) P30152-P1091-A1 P30152-P1091-A1 P30152-P1091-A1 CTI TAPI 3P V2 (30 users) F50035-E302-X11 F50035-E302-X11 F50035-E302-X11 CTI TAPI 3P V2 (80 users) F50035-E302-X12 F50035-E302-X12 F50035-E302-X12 CTI TAPI 3P V2 (250 users) F50035-E302-X13 F50035-E302-X13 F50035-E302-X13 Hicom client (kit for 4 clients) F50035-E4-X5 F50035-E4-X5 F50035-E4-X5 Telematic Fritz SW (4 clients) P30152-B6-A1 P30152-B6-A1 P30152-B6-A1 Smartset 2000 for ISDN (SW) P30152-B1-A10 P30152-B1-A10 P30152-B1-A10 Adapter (international)
Adapter (USA) LAN adapter cable (U.S. only)
with female connector LAN adapter cable (U.S. only)
with male connector Ferrite (kit) L30460-X1358-X -- -­V.24 cable S30122-X5468-X3 S30122-X5468-X3 S30122-X5468-X3
--
--
--
--
C39228-A7195-A10 C39195-Z7404-A10
C39195-Z7406-A2-1­7425
C39195-Z7407-A2-1­7425
A31003-K5020-S100-6-7620 Service Manual
2-13
lan2de.c02
Installation
HiPath HG 1500 boards

2.3 HiPath HG 1500 installation

2.3.1 Installation requirements

Free slot for boards
Hicom 150 E Office as of SW Version 2.2/Hicom 150 HV 1.0
ISDN trunk connection
LAN connection
See also Ta b l e 2 - 1 and Ta b l e 2 - 5
A DSL port is necessary for the HXGS/HXGM board with 2nd LAN

2.3.2 Slot

Special country variants are not provided for. Examples of maximum system config­urations:
For internal use only
System Slot Configuration Trunk Station
OfficePoint 2 SLA 4/8/16
SLU8
16 ports ISDN So MSI lines
8 Upo/E + 16 from
STLS 2/4 TLA 2/4/8 HiPath HG 1500
OfficeCom 6 SLA 4/8/16
SLU8 STLS 2/4
30 ports ISDN S2m ISDN So MSI lines
24 Upo/E + 48 from
TLA 2/4/8 TS 2 HiPath HG 1500
Table 2-13 Slots
Maximum system configurations for Hicom 150 E OfficePro are contained in the Hi­com 150 E Office/Hicom 150 H Service Manual.
2-14
A31003-K5020-S100-6-7620
Service Manual
s
lan2de.c02
For internal use only

2.3.3 Installation procedure

Step Task
1. Remove the power plug.
2. Insert the board.
3. Insert the power plug.
Table 2-14 Installation procedure in the case of OfficePoint/Com
This sequence must be observed in order to guarantee successful LAN board login.
Note
In the case of Hicom 150 E/H OfficePro, the board can be plugged and unplugged without disconnecting the power supply.
Installation
HiPath HG 1500 board
A31003-K5020-S100-6-7620 Service Manual
2-15
lan2de.c02
Installation
HiPath HG 1500 boards
For internal use only
2-16
A31003-K5020-S100-6-7620
Service Manual
0
lan2de.c03
For internal use only

3 Startup

3.1 Initial startup of HiPath HG 1500

Note
Windows 3.11 is no longer supported.

3.1.1 Initial startup: Remote via modem

Prerequisites
The feature is only available as of Hicom Rel. 3 SMR-E with Assistant Office P30300­P1584-A1-02 and SMR-11 HG1500. Hicom must be configured for remote adminis­tration and HiPath HG 1500 must be in the default state (default customer database).
Startup
Initial startup of HiPath HG 150
Step Task
1. Using Assistant E, read out the contents of the board using the Restart/ Reload option "Maintenance". Then enter an extension in the numbering plan. (Recommendation: Pro -748, Com -686, Point -69)
2. Transfer the changes into Hicom using "Transfer data"
3. The following changes will automatically be made in the customer data­base for HiPath HG 1500:
- the ISDN peer "remote default" will be set with the following parameters: IP address: 10.186.237.64 CHAP user ID: 31994 (Host = On) CHAP password: 31994 V.34 peer: Yes
- the ISDN2 interface is assigned the IP address 10.186.237.63
- the IP address 10.186.237.64 is assigned administration rights
4. A new dial-up networking connection with the following data is generated on the PC (here W98): Connect via: Standard 19200 bps modem (dependent on the modem in use) Type of Dial-Up Server> PPP Windows 95, Windows NT 3.5 Logon to the network: No Activate software compression: No Request encrypted password: No NetBEUI: No IPX/SPX: No Define IP address: 10.186.237.64 Use IP header compression: No Use the standard GW in the remote network: No
existing
call number as an
A31003-K5020-S100-6-7620 Service Manual
3-1
lan2de.c03
Startup
Initial startup of HiPath HG 1500
Step Task
5. HiPath HG 1500 can now be administered remotely with Assistant Xpress @LAN/HG 1500.
Note
The CHAP user ID and password are identical to the of the Hicom user group system administration (generally 31994/31994).

3.1.2 Startup via ARP

HiPath HG 1500 can be assigned an IP address using a static entry in the ARP table of the Administration PC.
Prerequisites
The network card with the TCP/IP protocol must function correctly. The Xpress @LAN assistant must be installed on the PC.
For internal use only
first
user name and password
Step Task
Note
These settings are temporary and are only stored permanently on the board on entry to the customer database. The HiPath HG 1500 default IP address (10.144.233.63) is reserved for startup and cannot be used as a permanent IP address in the network.
Security note
As long as a customer database has not been transferred to the board, the process described above can be used by every PC in the LAN.
1. In the MS-DOS command window, enter the command
arp -s ipadresse macadresse
(Format example: arp -s 192.168.100.245 08-00-06-0f-ec-04) The board MAC address is indicated on the adhesive label on the board.
2. From the MS-DOS command window ping HiPath HG 1500 using the new IP address. If the ping has been answered successfully by HiPath HG 1500, administration of this PC can proceed.
3-2
A31003-K5020-S100-6-7620
Service Manual
0
lan2de.c03
For internal use only

3.1.3 Initial startup via the serial interface

Note
The serial interface should only be used for initial startup if this is not possible via a LAN port.
Prerequisite
The SLIP connection in the dial-up network must be installed separately from the op­erating system.
Step Task
1. Connect the serial interface cable (S30122-X5468-X3).
2. Install Assistant Xpress @LAN/HG 1500.
Startup
Initial startup of HiPath HG 150
Note
3. Configure the IP address (1.0.0.2) of the PC (SLIP)
4. From the DOS command window, ping HiPath HG 1500 (IP 1.0.0.1).
5. Generate an empty customer database and load to HiPath HG 1500.
6. Save and administer customer data.
The SLIP configuration on the PC is described in detail in the Administration Docu­ments Hicom 150 E Office for HiPath HG 1500.
A31003-K5020-S100-6-7620 Service Manual
3-3
lan2de.c03
Startup
Initial startup of HiPath HG 1500

3.2 Configuration for gatekeeper mode

Figure 3-1 Installation for gatekeeper mode
Group 1
Optiset 100 200
HXGM/HXGS
HiPath HG 1500
H.323 client
Group 2
For internal use only
HFA client
300
LAN
Note
H.323 GK
LP5100
201
Administration
Hicom 150 E Office
The following stations must be differentiated from the user’s viewpoint:
Group 1
: stations directly connected to the Hicom (Optisets, POT, CMI, ...), stations registered at HiPath HG 1500 (C55 Opti clients, vCAPI clients) and all trunk access­es.
Group 2
: stations registered at the gatekeeper (H.323 standard clients such as Net­meeting 3.01, HiNet LP5100, HiNet TA1100, etc.).
In order to reach a port (station/line) of group 1, all stations of group 2 must dial an additional code. This code is deleted in the direction to the Hicom by HiPath HG 1500 and inserted for traffic in the reverse direction, i.e., stations of group 1 do not dial the code.
3-4
The code must be set up in the RADVision Gatekeeper NGK100 as a service and in HiPath HG 1500 as a gateway prefix.
A31003-K5020-S100-6-7620
Service Manual
0
lan2de.c03
For internal use only

3.2.1 Configuration HiPath HG 1500

Step Task
1. Under Enter the IP address of the PC with the gatekeeper, enable gatekeeper support and configure the prefix.
2. Under Configure the clients with a gatekeeper connection using IP address "255.255.255.255". Clients without a gatekeeper connection must be configured with the fixed IP addresses of the corresponding PCs.
3. Under There are no additional aspects to be noted here.
Voice Clients -> Gatekeeper
Voice Clients -> H.323 Clients
Voice Clients -> Xpress Clients
Startup
Initial startup of HiPath HG 150
:
:
:

3.2.2 Configuring the NGK 100 gatekeeper

Relevant options under "Settings
Step Task
1. Capacity Characteristics: Set the
IRQ interval
clically polled, e.g. when using RAS connections for teleworking.
2. Call and Registration Policy:
Accept Call
All Endpoints
Set
must be enabled.
or
3. Routing Mode:
Gatekeeper Routed
Set
"
to 0 if the registered endpoints do not need to be cy-
Predefined endpoints
Direct Routed
or
.
.
A31003-K5020-S100-6-7620 Service Manual
3-5
lan2de.c03
Startup
Initial startup of HiPath HG 1500
Configuring Services
Step Task
1. Press the
2. Under
3. Under
Services
Description
Prefix
1500 gateway prefix set up in the HLB0, e.g. "0" (only digits, possibly mul­tiple).
4. Enable
Allow as default for online endpoints
signed to all endpoints registered at the gateway (otherwise, the service will need to be individually assigned to each endpoint that may use it).
5. Enable
Allow for public endpoints from other zones
other H.323 zones may use the service.
Configuring neighbors
For internal use only
button and then click
Add
.
, enter a description for the service, e.g. "Hicom 150 E".
, enter the correct code, which must match the HiPath HG
if the service is to be as-
if endpoints from
Note
Step Task
1. Press the
2. Under
Description
Neighbors
, enter a description for the other zone, e.g. "Depart-
button and then click
Add
.
ment XYZ".
3. Under
IP address
, enter the IP address of the gatekeeper for the other
zone.
Detailed configuration examples can be found in the Administration Manual for HiPath HG 1500 (A31003-K5020-B811-*-7619).
3-6
A31003-K5020-S100-6-7620
Service Manual
e
lan2de.c04
For internal use only

4 Administration

Information on status diagnostics for HiPath HG 1500 such as DSS, PPP, Firewall, HFA client, H.323, vCAPI, etc. is contained in the HiPath HG 1500 Administrator Manual under Customer trace.

4.1 Tracing with development trace

Development trace must be deactivated when HiPath HG 1500 is in operation.
You must contact Development if you have problems or queries relating to develop­ment trace.
Note that all three traces for the board must be saved in the event of errors, i.e., the:
development trace,
customer trace and
Administration
Tracing with development trac
error memory.
If system crashes have occurred in connection with the board, make sure that you also produce a "stack dump" and submit it together with the traces to the responsible Development department.
The traces and the stack dump can withstand a reset, but are lost in the event of a power failure.

4.2 Determining the firmware version of the board

The firmware version of the board can be determined by dumping a memory area (possible in the Developer level of Assistant Xpress @LAN/HG 1500).
Step Task
1. Switch to the developer mode of Assistant Xpress @LAN/HG 1500.
2. Create a dump of the KDS (switches the menu items to developer mode).
3. Call up the "Service" menu and select "Receive and save a memory area".
4. Hex address FE000000 and size: Enter 20.
5. Enter a file name: e.g., FW.txt The file will now contain the version number of the firmware.
A31003-K5020-S100-6-7620 Service Manual
4-1
lan2de.c04
Administration
Tracing with development trace
For internal use only
4-2
A31003-K5020-S100-6-7620
Service Manual
s
lan2de.c05
For internal use only

5 Additional information

5.1 Integrating various network topologies

HiPath HG 1500 is equipped with a 10/100 MB Autosense twisted-pair port.

5.1.1 Star topology with hub (10/100 BaseT)

In the case of this network topology, a hub or switch is used as a central element. Each data terminal is connected to this via a separate twisted-pair cable (e.g. 10/100 BaseT-Ethernet). A standard hub emulates a bus internally. If a cable malfunctions, only one terminal is affected. The integrated HiPath HG 1500 can be connected di­rectly.
Additional information
Integrating various network topologie
Notes
HUB
LAN
LAN
PC
Figure 5-1 10/100 BaseT cabling
10/100 MBit/s Autosense
Max. total length from HUB/switch to PC = 100 m incl. PATCH cable.
LAN
PC
Hicom 150 E Office Hicom 150 H

5.1.2 Bus topology (10 Base2)

The traditional, but now redundant cabling method for Ethernet LANs. Coaxial cable is used to connect each data terminal via a T distributor to the main line. In a bus en­vironment, the data terminals are only connected via the cable - no additional hard­ware is required. However, because of the risk associated with failures and the limited
A31003-K5020-S100-6-7620 Service Manual
5-1
lan2de.c05
Additional information
Integrating various network topologies
load-bearing capacity of the network, structured (star) cabling is becoming increas­ingly popular. The integrated HiPath HG 1500 can only be connected via a hub or switch.
PC
For internal use only
Hicom 150 E Office Hicom 150 H
HUB
LAN
Note
PC
PC
PC
Figure 5-2 10 Base2 cabling
The coaxial cable must have terminating resistors at both ends.
No spur lines are permitted in the coaxial cable.
The T units must be positioned directly on the terminals.
Max. length of the LAN is 185 m.
5-2
A31003-K5020-S100-6-7620
Service Manual
d
lan2de.c05
For internal use only

5.2 SW upgrade

Upgrading from HiPath HG 1500 is performed via APS transfer.

5.3 Firmware Download

Firmware Download is only available at the developer level of the Assistant. This fea­ture is used to upgrade the firmware of a board to a new version. Such a firmware upgrade should only be performed if there are valid reasons (since the operation is comparable to a BIOS update on the PC)
Select the APS file with the firmware to be transferred (File Open dialog)
Additional information
Firmware Downloa
Assistant I checks as to whether the software of the selected HiPath HG 1500 system supports a firmware transfer. If this is not the case, the following error message will be displayed:
A31003-K5020-S100-6-7620 Service Manual
5-3
lan2de.c05
Additional information
Firmware Download
If a firmware transfer is supported, Assistant I indicates the software version of HiPath HG 1500 as well as the firmware versions which are currently available in the HiPath HG 1500 system and are contained in the APS file. This is followed by a warning message. If the user decides to continue with the transfer,
For internal use only
the firmware will be transferred.
Once the transfer has been completed successfully, the user is prompted to con­firm the changeover to the new firmware. Another warning message appears.
Assistant I prompts HiPath HG 1500 to perform changeover and HiPath HG 1500 reports whether the changeover has succeeded or failed.
5-4
Once changeover has been completed successfully, HiPath HG 1500 performs a RESET.
A31003-K5020-S100-6-7620
Service Manual
For internal use only
Abbreviations
This list contains the abbreviations used in this manual.
Abbreviation Definition
APS Application Programming System ARP Address Resolution Protocol CAPI Common ISDN Application Programming Interface CHAP Challenge Handshake Authentication Protocol CMI Cordless Multicell Integration CSTA Computer Supported Telecommunications Applications
lan2de.abb
CTI Computer Telephony Integration DFÜ German abbreviation for Dial-Up Networking DSP Digital Signal Processor DSS1 Digital Subscriber Signaling System One (D-channel protocol) EMC Electromagnetic Compatibility FW Firmware GSM Global System for Mobile Communication GK Gatekeeper H.323 ITU standard for voice over LAN HFA Hicom Feature Access MDF Main Distribution Frame HXGM Hicom Xpress Gateway Medium HXGO Hicom Xpress Gateway One HXGS Hicom Xpress Gateway Small IEEE Institute of Electrical and Electronics Engineers IP Internet Protocol ITU International Telecommunication Union KDS Customer database LAN Local Area Network LCR Least Cost Routing
A31003-K5020-S100-6-7620 Service Manual
Y-1
lan2de.abb
MAC Media Access Control MODEM Modulator/Demodulator MSN Multiple Subscriber Number NAT Network Address Translation POT a/b telephone (analog telephone) PAP Password Authentication Protocol PING Packet Internet Groper PPP Point-to-Point Protocol RARP Reverse Address Resolution Protocol RAS Remote Access Service SIC Serial Interface Cable
For internal use only
SLA Subscriber Line Analog (Hicom board) SLIP Serial Line Interface Protocol SLU Subscriber Line UP0/E (Hicom board) SMR Service Maintenance Release SNMP Simple Network Management Protocol STLS Subscriber Trunk Line S0 (Hicom board) CTRL Control TAPI Telephony Application Programming Interface TCP Transmission Control Protocol TLA Trunk Line Analog (Hicom board) TS2 Trunk module S2M (Hicom board) vCAPI Virtual CAPI WAN Wide Area Network
Y-2
A31003-K5020-S100-6-7620
Service Manual
lan2deix.fm
For internal use only
Index
Index X
A Adapter for HXGM backplane 2-8 Administration 4-1 Assignment of the SIPAC-RJ45 LAN adapter 2-9 B Bus topology (10 Base2) 5-1 C Configure HiPath HG 1500 3-5 Configuring the NGK 100 gatekeeper 3-5 Contact assignment of the HXGM LAN interfaces 2-11 D Determining the firmware version of the board 4-1 F Firmware Download 5-3 G Gatekeeper 1-5 gatekeeper mode
installing 3-4 H Hicom password concept 1-4 HiPath HG 1500
Functional environment 1-5
Parallel operation 1-5 HiPath HG 1500 Assistant 1-3 HiPath HG 1500 boards 2-1 HiPath HG 1500 installation 2-14 HXGM 2-6 HXGM application option/slot 2-6 HXGM hardware variants 2-6 HXGM interfaces (S30810-Q2930-X/X100) 2-7 HXGM LED concept 2-10 HXGM V.24 interface 2-11 HXGS 2-1 HXGS application option/slot 2-1 HXGS hardware variants 2-2 HXGS V.24 interface 2-4, 2-5 I Initial startup
Remote via modem 3-1 Initial startup of HiPath HG 1500 3-1 Initial startup via the serial interface 3-3 Installation 2-1
A31003-K5020-S100-6-7620 Service Manual
Z-1
lan2deix.fm
Index
Installation requirements 2-14 Integrating various network topologies 5-1 Interface
LAN 2-12 L Least Cost Routing (LCR) 1-5 P Part numbers 2-13 R RJ45 socket assignment (HXGM) 2-8 S Service information 1-3 Short description 1-2 Slot 2-14 Star topology with hub (10/100 BaseT) 5-1 Starting Hicom system administration (Service) 1-4 Startup 3-1 Startup via ARP 3-2 SW upgrade 5-3 T Toll restriction 1-5 Tracing with development trace 4-1 Trunk access 1-5 V V.24 socket assignment (HXGM2) 2-11