Siemens AG 2001
Reference no.: A31003-K5020-S100-6-7620
Printed in the Federal Republic of Germany.
Subject to availability. Right of modification reserved.
Information and Communication Networks, Hofmannstraße 51, D-81359 München
Table 2-14Installation procedure in the case of OfficePoint/Com . . . . . . . . . . . . . . 2-15
A31003-K5020-S100-6-7620
Service Manual
0-5
lan2delot.fm
Tab le s
For internal use only
0-6
A31003-K5020-S100-6-7620
Service Manual
lan2de.c01
For internal use only
1 Introduction
This service manual refers to HiPath HG 1500 V 1.0/V 2.0 as well as Hicom Xpress
@LAN V1.1 with the LAN boards HXGS and HXGM.
HiPath HG 1500 supports the standard functions of ISDN (IP/IPX) routers together
with the additional functionality of a voice gateway (H.323). A virtual CAPI interface
(vCAPI) and a TAPI interface (CSTA) are also provided. The system also facilitates
PC-supported telephony (CTI) and HiPath HG 1500 administration via a LAN PC.
Caution
7
All safety instructions for service and technical personnel given in the "Important Information" section of the Hicom 150 E Office/Hicom 150 H Service Manual are also
applicable to HiPath HG 1500 and must be observed.
Only authorized staff should work on the system.
Introduction
Note
Note that when configuring voice applications, only S30810-Q2930/Q2940-X
(HXGM/HXGM2) and S30810-Q2931/Q2939-X (HXGS/HXGS2) boards may be
used.
1.1 HiPath HG 1500
Hicom Xpress @LAN and HiPath HG 1500 create a bridge between the LAN and the
ISDN network via an integrated HXGS/HXGM board
Suitable for:
●
Hicom 150 E Office Version 2.2 and later or Hicom 150 H V 1.0 or later, OfficePoint/OfficeCom/OfficePro model
The following implementation scenarios are possible:
●
Voice gateway between LAN (H.323) and standard telephones (e.g. Netmeeting),
●
Telephoning from the PC (voice over IP) with Optiset features at the PC or via the
Xpress client,
●
WAN connections via the ISDN network, including PPP Multilink,
●
Remote access from within company LANs (provided via analog V34, GSM V110
and ISDN),
●
Internet access (PPP router, NAT),
A31003-K5020-S100-6-7620
Service Manual
1-1
lan2de.c01
Introduction
●
vCAPI for client PCs including fax services and CTI,
●
SNMP (e.g. statistics and error signaling),
●
Routing via the xDSL network (for HXGS with 2nd LAN interface only).
Interfaces:
●
10/100BT Autosense Ethernet twisted-pair,
●
10BT Ethernet (for HXGS with 2nd LAN interface only) configurable with PPPoE,
●
Up to 16 B channels,
●
SLIP access (serial line interface) for initial startup, incl. cable (reference no.
S30122-X5468-X3).
1.1.1 Prerequisite
For this application, TCP/IP is implemented as the transport protocol and Win95/98/
NT 4.0 or Windows 2000 as the client operating system. For the routing functionality,
the IP/IPX protocols are transferred transparently, independent of the operating system. Call numbers are allocated in HiPath HG 1500 via TCP/IP Address > Call Number (max. 100 call numbers for vCAPI and max. 48 stations for voice applications).
The assignment of several call numbers to one TCP/IP address may be necessary if
several services are to be configured (voice, fax, file transfer, etc.).
For internal use only
1.2 Short description
HiPath HG 1500 is an expansion card for Hicom 150 E Office/Hicom 150 H Point/
Com/Pro. It is used to connect a "local" LAN to Hicom systems and to link "external"
LANs via the system’s ISDN interface. Telematics and CTI functions are also supported.
The connection to the "local" LAN is set up via an Ethernet twisted-pair interface
(RJ45 connector); see Figure 2-1 and Figure 2-4.
In the case of OfficePoint and Com, the connection to the system is set up via a 50pin edge connector of an expansion slot. The connection to the LAN is set up via an
RJ45 connector on the HiPath HG 1500 board.
In the case of OfficePro, the board is connected to the system via the backplane. An
adapter for the backplane (part number C39228-A7195-A10, US backplane: C39195Z7404-A10) is used to connect the LAN with an RJ45 connector.
V.24 interface
For loading and administration purposes (SLIP access), each system is provided with
an individual V.24 interface (cable reference no. S30122-X5468-X3). In both systems, the V.24 connector for SLIP access is located on the board.
1-2
A31003-K5020-S100-6-7620
Service Manual
lan2de.c01
For internal use only
1.3 Service information
The unique worldwide Ethernet address (MAC address) is a factory default and cannot be modified.
Card recognition is performed automatically in Hicom 150 E Office/Hicom 150 H,
Point/Com/Pro. HiPath HG 1500 is installed as an individual board type in Hicom 150
E Office/Hicom 150 H, Point/Com/Pro.
The following items can be administered in Hicom:
●
S0 station
●
Xpress clients
●
IP network lines
●
numbering scheme
●
associated dialing
Introduction
●
answer group (PC telephone)
●
call forwarding (PC to fax)
●
suppression of incoming 0
●
CSTA interface
Details on the initial startup and on accessing the board can be found in the HiPath
HG 1500 Administration Manual.
A separate tool (Assistant Xpress @LAN/HG 1500) that can also be used by the customer or the LAN administrator is provided for entering and modifying data, e.g. the
IP address of the customer LAN or ISDN numbers assigned to a communication partner. The data is permanently stored in HiPath HG 1500. HiPath HG 1500 Assistant
also facilitates the storage of a corresponding configuration file. This can then be retrieved if a board needs replacing. The tool also provides a facility for querying the
software version. Access to HiPath HG 1500 administration is password-protected.
This password can be changed; however, the Hicom password concept applies; see
Ta b l e 1 - 1 .
Note that only the user and Hicom passwords are allowed.
A simple functional test can be performed directly at the customer PC or on a service
PC with a network card, vCAPI driver and a CAPI-based application.
APS transfer for the HiPath HG 1500 board is usually performed via the LAN using
the Assistant or, in exceptional circumstances, via the V.24 interface using the Loader.
Cable with reference number S30122-X5468-X3 (see also Section 2.1.1.1 or
Section 2.1.2.1) is used for the V.24 port of the HiPath HG 1500 board.
A31003-K5020-S100-6-7620
Service Manual
1-3
lan2de.c01
Introduction
1.4 Hicom password concept
Table 1-1Starting Hicom system administration (Service)
StepInputExplanation
1.*95Start system administration
2.31994User: 31994 (default)
3.31994Password: 31994 (default)
1.
2.Confirm user and/or password
Further information is contained in the Hicom 150 E Office Rel. 2.0-3.0 Service Manual or Hicom 150 H V1.0.
✓
For internal use only
or
Change user and/or password
1-4
A31003-K5020-S100-6-7620
Service Manual
lan2de.c01
For internal use only
1.5 Functional environment of HiPath HG 1500
1.5.1 Parallel operation
Hicom 150 E Office/Hicom 150 HCom/Pro systems support parallel operation of several HiPath HG 1500 boards.
System type Number of boards
OfficePoint1
OfficeCom2
OfficePro3
1.5.2 Interworking with features
Introduction
1.5.2.1 Least Cost Routing (LCR)
In Hicom systems, LCR technology enables the most cost-effective connections via
ISDN.
1.5.2.2 Trunk access/toll restriction
Trunk access is configured in Hicom 150 H/HiPath HG 1500Point/Com/Pro for call
numbers used by Hicom 150 E Office. Hicom toll restriction for outgoing seizure is
performed based on this trunk access in the same way as for outgoing calls.
1.5.3 Gatekeeper
The following functions are performed by a gatekeeper in an H.323 network:
●
Registering H.323 end units,
●
Managing rights and services,
●
Converting station numbers to logical names or IP addresses and vice versa,
●
Managing bandwidth on the network side,
●
Registering gateways,
●
Registering multiconference units,
●
Can be linked to neighboring gatekeepers (zones).
The setup procedure for gatekeeper operations is described in Section 3.1.3.
A31003-K5020-S100-6-7620
Service Manual
1-5
lan2de.c01
Introduction
If no gateways or multiconference units are being used, IP telephony can also be
>
implemented in H.323 networks without gatekeepers. Note, however, that the connection can only be set up via the IP address in this case, so no authorizations and
bandwidth control are possible.
In general, the following applies: without gatekeepers, many features may be disabled or subject to severe restrictions.
For internal use only
1-6
A31003-K5020-S100-6-7620
Service Manual
s
lan2de.c02
For internal use only
2 Installation
2.1 HiPath HG 1500 boards
HG 1500 supports two function groups: the “voice functionality” with the features
H.323 GW and TFA and the “data functionality” with the features VCAPI and RAS. A
board variant (X100) that only supports the data functionality (Data only) is available;
this board is not equipped with signal processors and the associated logic.
2.1.1 HXGS
Introduction
The HiPath HG 1500 board HXGS connects Hicom 150 E Office/Hicom 150 H OfficeCom/OfficePoint with the LAN environment. The board supports up to 16 B channels.
The following board variants are available:
HiPath HG 1500 HXGS Voice and Data (S30810-Q2931-X)
HiPath HG 1500 HXGS Data only (S30810-Q2931-X100)
HiPath HG 1500 HXGS2 Voice and Data 2nd LAN interface (S30810-Q2939-X000)
HiPath HG 1500 HXGS2 Data only 2nd LAN interface (S30810-Q2939-X100)
Installation
HiPath HG 1500 board
Board slot
Table 2-1HXGS application option/slot
Possible applicationBoardsSlot
OfficePoint
OfficeCom
Old HW
CBFC
OfficeCom
New HW
CBPC
Hicom 150 E as of V 2.2
P30370-P722-A680-*
Hicom 150 H as of V 1.0
P30370-P802-A680-*
Hicom 150 H as of V 1.2
P30370-P822-A680-*
Hicom 150 E as of V 2.2
P30370-P723-A680-G1
Hicom 150 E as of V 2.2
P30370-P721-A680-*
Hicom 150 H as of V 1.0
P30370-P801-A680-*
Hicom 150 H as of V 1.2
P30370-P821-A680-*
1All slots
2 *Slots 4 and 5 only
2 *All slots
A31003-K5020-S100-6-7620
Service Manual
2-1
lan2de.c02
Installation
HiPath HG 1500 boards
Table 2-1HXGS application option/slot
* = 2 boards may be operated in parallel
OfficeCom, old HW, CBFC: S30810-Q2950-X
OfficeCom, new HW, CBPC: S30810-Q2932-A201
Table 2-2HXGS hardware variants
System typeServicesDSPsBoard ID
OfficeCom/PointData only0HXGS
OfficeCom/PointVoice/Data4HXGS
OfficeCom/PointData only (2nd LAN)0HXGS2
OfficeCom/PointVoice/Data (2nd
For internal use only
Possible applicationBoardsSlot
4HXGS2
LAN)
2 simultaneous Voice over IP connections are possible for each DSP (Digital Signal
Processor).
Interfaces/connectors
The LAN port is linked at the X3/X4 connectors. For connector assignment, see
Ta b l e 2 - 3 .
The board is equipped with a 50-pin edge connector to the system, two Western
sockets (8-pin, 10-pin shielded) to the LAN and a shielded MiniDin socket (6-pin) for
the V.24 interface:
●
X1: 50-pin to the system
●
X2: 6-pin shielded MiniDin socket for V.24 interface, see Section 2.1.1.1
The following connection option is provided for connection to a LAN:
●
X3: 8-pin Western socket for LAN 10/100 Base-T, RJ45 socket (twisted pair)
for station
●
X4: 8-pin Western socket for LAN 10 Base-T, RJ45 socket (twisted pair)
for trunk connection (
for HXGS2 board with 2nd LAN interface only
)
2-2
A31003-K5020-S100-6-7620
Service Manual
s
lan2de.c02
For internal use only
LAN
connection
Installation
HiPath HG 1500 board
HXGS
50
V. 2 4X2
X1
to
CUC/
10/100 Base-TX3
CUP
2
Figure 2-1HXGS interfaces (S30810-Q2931-X/X100)
HXGS2
with 2nd LAN interface
50
V. 2 4X2
LAN
connections
10 Base-T (trunk)X4
X1
to
CUC/
10/100 Base-T (station)X3
CUP
2
Figure 2-2HXGS2 interfaces with 2nd LAN (S30810-Q2939-X000/X100)
A twisted-pair cable is used as the transmission medium for 10/100 Base-T and 10
Base-T.
A31003-K5020-S100-6-7620
Service Manual
2-3
lan2de.c02
Installation
HiPath HG 1500 boards
The cable is connected to the HiPath HG 1500 HXGS/HXGS2 (OfficeCom and OfficePoint) via the 8-pin Western socket (X3) located on the MDF side of the circuit
board, see Figure 2-1, or X3 and X4, see Figure 2-2.
Table 2-3Contact assignment of the HXGS LAN interfaces
Direct Ethernet twisted-pair connection to HiPath HG 1500
The RJ45 cable must be crossed as follows:
1 <> 32 <> 63 <> 16 <> 2
A ferrite kit must be installed on the LAN 1 and LAN 2 lines on the RJ45 cable.
2.1.1.1 HXGS V.24 interface
The Serial Interface Cable (SIC, S30122-K5468-X3-*) can be connected via a 6-pin
MiniDin socket on the front panel of the HXGS. The SIC performs level conversion
from TTL signals (HXGS) to V.24 (9-pin Sub-D socket). Depending on the SIC, the
maximum authorized transmission rate for the V.24 interface is 19.2 kBit/s. Asynchronous transmission only is supported.
The interface is used for administration purposes. It can be used for software updates
or board configuration. It can also be used for software debugging.
2-4
A31003-K5020-S100-6-7620
Service Manual
s
lan2de.c02
For internal use only
Table 2-4HXGS V.24 interface
PinSignalI/OFunction
1GND
2TXDOTransmit Data
3CTSIClear to Send
4RXDIReceive Data
5RTSORequest to Send
6+5V
(7)GND
Installation
HiPath HG 1500 board
A31003-K5020-S100-6-7620
Service Manual
2-5
lan2de.c02
Installation
HiPath HG 1500 boards
2.1.2 HXGM
Introduction
The HiPath HG 1500 board HXGM connects the Hicom 150 H OfficePro with the LAN
environment. The board supports up to 16 B channels.
The following board variants are available:
HiPath HG 1500 HXGM Voice and Data (S30810-Q2930-X)
HiPath HG 1500 HXGM Data only (S30810-Q2930-X100)
HiPath HG 1500 HXGM2 Voice and Data 2nd LAN interface (S30810-Q2940-X000)
HiPath HG 1500 HXGM2 Data only 2nd LAN interface (S30810-Q2940-X100)
Board slot
Table 2-5HXGM application option/slot
For internal use only
Possible applicationBoardsSlot
OfficePro
Hicom 150 E as of V 2.2
3 *All slots, except 2
P30370-P720-A680-*
Hicom 150 H as of V 1.0
P30370-P800-A680-*
Hicom 150 H as of V 1.2
P30370-P820-A680-*
* = Several boards may be operated in parallel
Table 2-6HXGM hardware variants
System typeServicesDSPsBoard ID
OfficeProData only0HXGM
OfficeProVoice/Data8HXGM
OfficeProData only (2nd LAN)0HXGM2
OfficeProVoice/Data (2nd
8HXGM2
LAN)
2 simultaneous Voice over IP connections are possible for each DSP (Digital Signal
Processor).
2-6
A31003-K5020-S100-6-7620
Service Manual
s
lan2de.c02
For internal use only
Interfaces/connectors
●
X10: 6-pin shielded MiniDin socket for V.24 cable; see Section 2.1.2.1
●
The board is connected to the system via the backplane. An adapter for the backplane (part number C39228-A7195-A10, US backplane: C39195-Z7404-A10) is
used to connect the LAN with an RJ45 connector, see Figure 2-4.
LED H2 (green)
LED H1 (red)
Installation
HiPath HG 1500 board
Backplane
HXGM/HXGM2
V. 2 4X10
*) LAN 2 - for HXGM board with 2nd LAN interface only
1TDPOTransmit Data +
2TDNOTransmit Data 3RDPIReceive Data +
4(TT1)ITransmit Termination 1
5(TT2)ITransmit Termination 2
6RDNIReceive Data 7(RT1)IReceive Termination 1
8(RT2)IReceive Termination 2
1SU-SIPAC connector
2-8
The TT1/2 and RT1/2 signals are not necessary for data transmission. They represent a signal termination of 100 ohms (known as a Bob Smith Termination) for the two
unused wire pairs in a four-pair twisted-pair cable.
Contact is established between the LAN and RJ45 via a CHAMP adapter cable. The adapter is
connected to the CHAMP socket on the rear of the backplane which is assigned to the HG 1500
slot. Both the adapter cable and the connector are shielded.
female
male
Figure 2-5LAN adapter cable (U.S. only)
A31003-K5020-S100-6-7620
Service Manual
10/100 Base-T
10 Base-T
2-9
lan2de.c02
Installation
HiPath HG 1500 boards
Table 2-9Assignment of the CHAMP-RJ45 LAN adapter cable
The Serial Interface Cable (SIC, S30122-K5468-X3-*) can be connected via a 6-pin
MiniDin socket on the front panel of the HXGM. The SIC performs level conversion
from TTL signals (HXGM2) to V.24 (9-pin Sub-D socket). Depending on the SIC, the
maximum authorized transmission rate for the V.24 interface is 19.2 kBit/s. Asynchronous transmission only is supported.
The interface is used for administration purposes. It can be used for software updates
or board configuration. It can also be used for software debugging.
Table 2-12V.24 socket assignment (HXGM2)
PinSignalI/OFunction
1GND
2TXDOTransmit Data
3CTSIClear to Send
4RXDIReceive Data
5RTSORequest to Send
6+5V
A31003-K5020-S100-6-7620
Service Manual
2-11
lan2de.c02
Installation
HiPath HG 1500 boards
Table 2-12V.24 socket assignment (HXGM2)
PinSignalI/OFunction
(7)GND
Note
A SLIP connection is required for Assistant administration of Xpress @LAN/HG 1500.
However, a SLIP connection is not possible for the Loader.
2.1.3 Interfaces to the LAN
The physical configuration of the LAN interface is predefined by the IEEE 802 standard. The interface conforms to international standards for electrical safety and electromagnetic compatibility (EMC). The electrically isolated coupling of the board at the
LAN is performed by the send and receive transmitter. The maximum transmission
speed of this "baseband" transmission technology is 100 MBit/s; the "Manchester"
signaling code is used.
The HiPath HG 1500 boards HXGS and HXGM are provided with a 10/100MB Autosense LAN port.
The HiPath HG 1500 boards HXGS2 and HXGM2 with a 2nd LAN interface are also
provided with a 10 BT LAN port, for example for routing via DSL.
For internal use only
2-12
A31003-K5020-S100-6-7620
Service Manual
s
lan2de.c02
For internal use only
2.2 Part numbers
HXGM Data only ----S30810-Q2930-X100
HXGM Voice and Data ----S30810-Q2930-X
HXGM2 Data only----S30810-Q2940-X100
HXGM2 Voice and Data ----S30810-Q2940-X000
HXGS Data only S30810-Q2931-X100 S30810-Q2931-X100 -HXGS Voice and Data S30810-Q2931-XS30810-Q2931-X-HXGS2 Data only with 2nd
LAN
HXGS2 Voice and Data
with 2nd LAN
Assistant Xpress @LAN
HG 1500
Installation
HiPath HG 1500 board
IDPart number
OfficePointOfficeComOfficePro
S30810-Q2939-X100 S30810-Q2939-X100 --
S30810-Q2939-X000 S30810-Q2939-X000 --
P30300-P1562-A1P30300-P1562-A1P30300-P1562-A1
LoaderP30300-P1509-*P30300-P1509-*P30300-P1509-*
CSTA converterP30300-P1530-A1P30300-P1530-A1P30300-P1530-A1
vCAPI (SW)P30300-P1561-A1P30300-P1561-A1P30300-P1561-A1
CTI TAPI 1P (4 clients)P30152-P1091-A1P30152-P1091-A1P30152-P1091-A1
CTI TAPI 3P V2 (30 users)F50035-E302-X11F50035-E302-X11F50035-E302-X11
CTI TAPI 3P V2 (80 users)F50035-E302-X12F50035-E302-X12F50035-E302-X12
CTI TAPI 3P V2 (250 users)F50035-E302-X13F50035-E302-X13F50035-E302-X13
Hicom client (kit for 4 clients)F50035-E4-X5F50035-E4-X5F50035-E4-X5
Telematic Fritz SW (4 clients)P30152-B6-A1P30152-B6-A1P30152-B6-A1
Smartset 2000 for ISDN (SW) P30152-B1-A10P30152-B1-A10P30152-B1-A10
Adapter (international)
Adapter (USA)
LAN adapter cable (U.S. only)
with female connector
LAN adapter cable (U.S. only)
with male connector
Ferrite (kit)L30460-X1358-X---V.24 cableS30122-X5468-X3S30122-X5468-X3S30122-X5468-X3
--
--
--
--
C39228-A7195-A10
C39195-Z7404-A10
C39195-Z7406-A2-17425
C39195-Z7407-A2-17425
A31003-K5020-S100-6-7620
Service Manual
2-13
lan2de.c02
Installation
HiPath HG 1500 boards
2.3 HiPath HG 1500 installation
2.3.1 Installation requirements
●
Free slot for boards
●
Hicom 150 E Office as of SW Version 2.2/Hicom 150 HV 1.0
●
ISDN trunk connection
●
LAN connection
●
See also Ta b l e 2 - 1 and Ta b l e 2 - 5
●
A DSL port is necessary for the HXGS/HXGM board with 2nd LAN
2.3.2 Slot
Special country variants are not provided for. Examples of maximum system configurations:
For internal use only
SystemSlotConfigurationTrunkStation
OfficePoint2SLA 4/8/16
SLU8
16 ports ISDN So
MSI lines
8 Upo/E + 16 from
STLS 2/4
TLA 2/4/8
HiPath HG 1500
OfficeCom6SLA 4/8/16
SLU8
STLS 2/4
30 ports ISDN
S2m ISDN So
MSI lines
24 Upo/E + 48
from
TLA 2/4/8
TS 2
HiPath HG 1500
Table 2-13Slots
Maximum system configurations for Hicom 150 E OfficePro are contained in the Hicom 150 E Office/Hicom 150 H Service Manual.
2-14
A31003-K5020-S100-6-7620
Service Manual
s
lan2de.c02
For internal use only
2.3.3 Installation procedure
StepTask
1.Remove the power plug.
2.Insert the board.
3.Insert the power plug.
Table 2-14Installation procedure in the case of OfficePoint/Com
This sequence must be observed in order to guarantee successful LAN board login.
Note
In the case of Hicom 150 E/H OfficePro, the board can be plugged and unplugged
without disconnecting the power supply.
Installation
HiPath HG 1500 board
A31003-K5020-S100-6-7620
Service Manual
2-15
lan2de.c02
Installation
HiPath HG 1500 boards
For internal use only
2-16
A31003-K5020-S100-6-7620
Service Manual
0
lan2de.c03
For internal use only
3 Startup
3.1 Initial startup of HiPath HG 1500
Note
Windows 3.11 is no longer supported.
3.1.1 Initial startup: Remote via modem
Prerequisites
The feature is only available as of Hicom Rel. 3 SMR-E with Assistant Office P30300P1584-A1-02 and SMR-11 HG1500. Hicom must be configured for remote administration and HiPath HG 1500 must be in the default state (default customer database).
Startup
Initial startup of HiPath HG 150
StepTask
1.Using Assistant E, read out the contents of the board using the Restart/
Reload option "Maintenance". Then enter an
extension in the numbering plan. (Recommendation: Pro -748, Com -686,
Point -69)
2.Transfer the changes into Hicom using "Transfer data"
3.The following changes will automatically be made in the customer database for HiPath HG 1500:
- the ISDN peer "remote default" will be set with the following parameters:
IP address: 10.186.237.64
CHAP user ID: 31994 (Host = On)
CHAP password: 31994
V.34 peer: Yes
- the ISDN2 interface is assigned the IP address 10.186.237.63
- the IP address 10.186.237.64 is assigned administration rights
4.A new dial-up networking connection with the following data is generated
on the PC (here W98):
Connect via: Standard 19200 bps modem (dependent on the modem in
use)
Type of Dial-Up Server> PPP Windows 95, Windows NT 3.5
Logon to the network: No
Activate software compression: No
Request encrypted password: No
NetBEUI: No
IPX/SPX: No
Define IP address: 10.186.237.64
Use IP header compression: No
Use the standard GW in the remote network: No
existing
call number as an
A31003-K5020-S100-6-7620
Service Manual
3-1
lan2de.c03
Startup
Initial startup of HiPath HG 1500
StepTask
5.HiPath HG 1500 can now be administered remotely with Assistant Xpress
@LAN/HG 1500.
Note
The CHAP user ID and password are identical to the
of the Hicom user group system administration (generally 31994/31994).
3.1.2 Startup via ARP
HiPath HG 1500 can be assigned an IP address using a static entry in the ARP table
of the Administration PC.
Prerequisites
The network card with the TCP/IP protocol must function correctly. The Xpress @LAN
assistant must be installed on the PC.
For internal use only
first
user name and password
StepTask
Note
These settings are temporary and are only stored permanently on the board on entry
to the customer database. The HiPath HG 1500 default IP address (10.144.233.63)
is reserved for startup and cannot be used as a permanent IP address in the network.
Security note
As long as a customer database has not been transferred to the board, the process
described above can be used by every PC in the LAN.
1.In the MS-DOS command window,
enter the command
arp -s ipadresse macadresse
(Format example: arp -s 192.168.100.245 08-00-06-0f-ec-04)
The board MAC address is indicated on the adhesive label on the board.
2.From the MS-DOS command window ping HiPath HG 1500 using the new
IP address. If the ping has been answered successfully by HiPath HG
1500, administration of this PC can proceed.
3-2
A31003-K5020-S100-6-7620
Service Manual
0
lan2de.c03
For internal use only
3.1.3 Initial startup via the serial interface
Note
The serial interface should only be used for initial startup if this is not possible via a
LAN port.
Prerequisite
The SLIP connection in the dial-up network must be installed separately from the operating system.
StepTask
1.Connect the serial interface cable (S30122-X5468-X3).
2.Install Assistant Xpress @LAN/HG 1500.
Startup
Initial startup of HiPath HG 150
Note
3.Configure the IP address (1.0.0.2) of the PC (SLIP)
4.From the DOS command window, ping HiPath HG 1500
(IP 1.0.0.1).
5.Generate an empty customer database and load to HiPath HG 1500.
6.Save and administer customer data.
The SLIP configuration on the PC is described in detail in the Administration Documents Hicom 150 E Office for HiPath HG 1500.
A31003-K5020-S100-6-7620
Service Manual
3-3
lan2de.c03
Startup
Initial startup of HiPath HG 1500
3.2 Configuration for gatekeeper mode
Figure 3-1Installation for gatekeeper mode
Group 1
Optiset 100200
HXGM/HXGS
HiPath HG 1500
H.323 client
Group 2
For internal use only
HFA client
300
LAN
Note
H.323 GK
LP5100
201
Administration
Hicom 150 E Office
The following stations must be differentiated from the user’s viewpoint:
Group 1
: stations directly connected to the Hicom (Optisets, POT, CMI, ...), stations
registered at HiPath HG 1500 (C55 Opti clients, vCAPI clients) and all trunk accesses.
Group 2
: stations registered at the gatekeeper (H.323 standard clients such as Netmeeting 3.01, HiNet LP5100, HiNet TA1100, etc.).
In order to reach a port (station/line) of group 1, all stations of group 2 must dial an
additional code. This code is deleted in the direction to the Hicom by HiPath HG 1500
and inserted for traffic in the reverse direction, i.e., stations of group 1 do not dial the
code.
3-4
The code must be set up in the RADVision Gatekeeper NGK100 as a service and in
HiPath HG 1500 as a gateway prefix.
A31003-K5020-S100-6-7620
Service Manual
0
lan2de.c03
For internal use only
3.2.1 Configuration HiPath HG 1500
StepTask
1.Under
Enter the IP address of the PC with the gatekeeper,
enable gatekeeper support and configure the prefix.
2.Under
Configure the clients with a gatekeeper connection using IP address
"255.255.255.255".
Clients without a gatekeeper connection must be configured with the fixed
IP addresses of the corresponding PCs.
3.Under
There are no additional aspects to be noted here.
Voice Clients -> Gatekeeper
Voice Clients -> H.323 Clients
Voice Clients -> Xpress Clients
Startup
Initial startup of HiPath HG 150
:
:
:
3.2.2 Configuring the NGK 100 gatekeeper
Relevant options under "Settings
StepTask
1.Capacity Characteristics:
Set the
IRQ interval
clically polled, e.g. when using RAS connections for teleworking.
2.Call and Registration Policy:
Accept Call
All Endpoints
Set
must be enabled.
or
3.Routing Mode:
Gatekeeper Routed
Set
"
to 0 if the registered endpoints do not need to be cy-
Predefined endpoints
Direct Routed
or
.
.
A31003-K5020-S100-6-7620
Service Manual
3-5
lan2de.c03
Startup
Initial startup of HiPath HG 1500
Configuring Services
StepTask
1.Press the
2.Under
3.Under
Services
Description
Prefix
1500 gateway prefix set up in the HLB0, e.g. "0" (only digits, possibly multiple).
4.Enable
Allow as default for online endpoints
signed to all endpoints registered at the gateway (otherwise, the service
will need to be individually assigned to each endpoint that may use it).
5.Enable
Allow for public endpoints from other zones
other H.323 zones may use the service.
Configuring neighbors
For internal use only
button and then click
Add
.
, enter a description for the service, e.g. "Hicom 150 E".
, enter the correct code, which must match the HiPath HG
if the service is to be as-
if endpoints from
Note
StepTask
1.Press the
2.Under
Description
Neighbors
, enter a description for the other zone, e.g. "Depart-
button and then click
Add
.
ment XYZ".
3.Under
IP address
, enter the IP address of the gatekeeper for the other
zone.
Detailed configuration examples can be found in the Administration Manual for HiPath
HG 1500 (A31003-K5020-B811-*-7619).
3-6
A31003-K5020-S100-6-7620
Service Manual
e
lan2de.c04
For internal use only
4 Administration
Information on status diagnostics for HiPath HG 1500 such as DSS, PPP, Firewall,
HFA client, H.323, vCAPI, etc. is contained in the HiPath HG 1500 Administrator
Manual under Customer trace.
4.1 Tracing with development trace
Development trace must be deactivated when HiPath HG 1500 is in operation.
You must contact Development if you have problems or queries relating to development trace.
Note that all three traces for the board must be saved in the event of errors, i.e., the:
●
development trace,
●
customer trace and
Administration
Tracing with development trac
●
error memory.
If system crashes have occurred in connection with the board, make sure that you
also produce a "stack dump" and submit it together with the traces to the responsible
Development department.
The traces and the stack dump can withstand a reset, but are lost in the event of a
power failure.
4.2 Determining the firmware version of the board
The firmware version of the board can be determined by dumping a memory area
(possible in the Developer level of Assistant Xpress @LAN/HG 1500).
StepTask
1.Switch to the developer mode of Assistant Xpress @LAN/HG 1500.
2.Create a dump of the KDS (switches the menu items to developer mode).
3.Call up the "Service" menu and select "Receive and save a memory area".
4.Hex address FE000000 and size: Enter 20.
5.Enter a file name: e.g., FW.txt
The file will now contain the version number of the firmware.
A31003-K5020-S100-6-7620
Service Manual
4-1
lan2de.c04
Administration
Tracing with development trace
For internal use only
4-2
A31003-K5020-S100-6-7620
Service Manual
s
lan2de.c05
For internal use only
5 Additional information
5.1 Integrating various network topologies
HiPath HG 1500 is equipped with a 10/100 MB Autosense twisted-pair port.
5.1.1 Star topology with hub (10/100 BaseT)
In the case of this network topology, a hub or switch is used as a central element.
Each data terminal is connected to this via a separate twisted-pair cable (e.g. 10/100
BaseT-Ethernet). A standard hub emulates a bus internally. If a cable malfunctions,
only one terminal is affected. The integrated HiPath HG 1500 can be connected directly.
Additional information
Integrating various network topologie
Notes
HUB
LAN
LAN
PC
Figure 5-110/100 BaseT cabling
●
10/100 MBit/s Autosense
●
Max. total length from HUB/switch to PC = 100 m incl. PATCH cable.
LAN
PC
Hicom 150 E Office
Hicom 150 H
5.1.2 Bus topology (10 Base2)
The traditional, but now redundant cabling method for Ethernet LANs. Coaxial cable
is used to connect each data terminal via a T distributor to the main line. In a bus environment, the data terminals are only connected via the cable - no additional hardware is required. However, because of the risk associated with failures and the limited
A31003-K5020-S100-6-7620
Service Manual
5-1
lan2de.c05
Additional information
Integrating various network topologies
load-bearing capacity of the network, structured (star) cabling is becoming increasingly popular. The integrated HiPath HG 1500 can only be connected via a hub or
switch.
PC
For internal use only
Hicom 150 E Office
Hicom 150 H
HUB
LAN
Note
PC
PC
PC
Figure 5-210 Base2 cabling
●
The coaxial cable must have terminating resistors at both ends.
●
No spur lines are permitted in the coaxial cable.
●
The T units must be positioned directly on the terminals.
●
Max. length of the LAN is 185 m.
5-2
A31003-K5020-S100-6-7620
Service Manual
d
lan2de.c05
For internal use only
5.2 SW upgrade
Upgrading from HiPath HG 1500 is performed via APS transfer.
5.3 Firmware Download
Firmware Download is only available at the developer level of the Assistant. This feature is used to upgrade the firmware of a board to a new version. Such a firmware
upgrade should only be performed if there are valid reasons (since the operation is
comparable to a BIOS update on the PC)
●
Select the APS file with the firmware to be transferred (File Open dialog)
Additional information
Firmware Downloa
●
Assistant I checks as to whether the software of the selected HiPath HG 1500
system supports a firmware transfer. If this is not the case, the following error
message will be displayed:
A31003-K5020-S100-6-7620
Service Manual
5-3
lan2de.c05
Additional information
Firmware Download
●
If a firmware transfer is supported, Assistant I indicates the software version of
HiPath HG 1500 as well as the firmware versions which are currently available
in the HiPath HG 1500 system and are contained in the APS file. This is followed
by a warning message. If the user decides to continue with the transfer,
For internal use only
●
the firmware will be transferred.
●
Once the transfer has been completed successfully, the user is prompted to confirm the changeover to the new firmware. Another warning message appears.
●
Assistant I prompts HiPath HG 1500 to perform changeover and HiPath HG 1500
reports whether the changeover has succeeded or failed.
5-4
●
Once changeover has been completed successfully, HiPath HG 1500 performs
a RESET.
A31003-K5020-S100-6-7620
Service Manual
For internal use only
Abbreviations
This list contains the abbreviations used in this manual.
CTIComputer Telephony Integration
DFÜGerman abbreviation for Dial-Up Networking
DSPDigital Signal Processor
DSS1Digital Subscriber Signaling System One (D-channel protocol)
EMCElectromagnetic Compatibility
FWFirmware
GSMGlobal System for Mobile Communication
GKGatekeeper
H.323ITU standard for voice over LAN
HFAHicom Feature Access
MDFMain Distribution Frame
HXGMHicom Xpress Gateway Medium
HXGOHicom Xpress Gateway One
HXGSHicom Xpress Gateway Small
IEEEInstitute of Electrical and Electronics Engineers
IPInternet Protocol
ITUInternational Telecommunication Union
KDSCustomer database
LANLocal Area Network
LCRLeast Cost Routing
A31003-K5020-S100-6-7620
Service Manual
Y-1
lan2de.abb
MACMedia Access Control
MODEMModulator/Demodulator
MSNMultiple Subscriber Number
NATNetwork Address Translation
POTa/b telephone (analog telephone)
PAPPassword Authentication Protocol
PINGPacket Internet Groper
PPPPoint-to-Point Protocol
RARPReverse Address Resolution Protocol
RASRemote Access Service
SICSerial Interface Cable
For internal use only
SLASubscriber Line Analog (Hicom board)
SLIPSerial Line Interface Protocol
SLUSubscriber Line UP0/E (Hicom board)
SMRService Maintenance Release
SNMPSimple Network Management Protocol
STLSSubscriber Trunk Line S0 (Hicom board)
CTRLControl
TAPITelephony Application Programming Interface
TCPTransmission Control Protocol
TLATrunk Line Analog (Hicom board)
TS2Trunk module S2M (Hicom board)
vCAPIVirtual CAPI
WANWide Area Network
Y-2
A31003-K5020-S100-6-7620
Service Manual
lan2deix.fm
For internal use only
Index
IndexX
A
Adapter for HXGM backplane 2-8
Administration 4-1
Assignment of the SIPAC-RJ45 LAN adapter 2-9
B
Bus topology (10 Base2) 5-1
C
Configure HiPath HG 1500 3-5
Configuring the NGK 100 gatekeeper 3-5
Contact assignment of the HXGM LAN interfaces 2-11
D
Determining the firmware version of the board 4-1
F
Firmware Download 5-3
G
Gatekeeper 1-5
gatekeeper mode
installing 3-4
H
Hicom password concept 1-4
HiPath HG 1500
Remote via modem 3-1
Initial startup of HiPath HG 1500 3-1
Initial startup via the serial interface 3-3
Installation 2-1
A31003-K5020-S100-6-7620
Service Manual
Z-1
lan2deix.fm
Index
Installation requirements 2-14
Integrating various network topologies 5-1
Interface
LAN 2-12
L
Least Cost Routing (LCR) 1-5
P
Part numbers 2-13
R
RJ45 socket assignment (HXGM) 2-8
S
Service information 1-3
Short description 1-2
Slot 2-14
Star topology with hub (10/100 BaseT) 5-1
Starting Hicom system administration (Service) 1-4
Startup 3-1
Startup via ARP 3-2
SW upgrade 5-3
T
Toll restriction 1-5
Tracing with development trace 4-1
Trunk access 1-5
V
V.24 socket assignment (HXGM2) 2-11
For internal use only
Z-2
A31003-K5020-S100-6-7620
Service Manual
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.