1 ABOUT THIS DOCUMENT
1About this document
1.1Function of this document
These operating instructions are intended to give technical personnel working for the
machine manuf
installation, commissioning, and operation of the TMS/TMM61 and TMS/TMM88 incli‐
nation sensors.
These operating instructions do not provide information on operating the machine in
which an inclination sensor is integrated. For information about this, refer to the operat‐
ing instructions of the particular machine.
1.2Explanation of symbols
Warnings in these operating instructions are labeled with symbols. The warnings are
int
oduced by signal words that indicate the extent of the danger. These warnings must
r
be observed at all times and care must be taken to avoid accidents, personal injury,
and material damage.
DANGER
… indica
injuries if not prevented.
tes a situation of imminent danger, which will lead to a fatality or serious
acturer or machine operator instructions on the mounting, electrical
WARNING
… indica
injuries if not prevented.
CAUTION
… indicates a potentially dangerous situation, which may lead to minor/slight injuries if
not prevented.
NOTICE
… indica
prevented.
NOTE
… hig
trouble-free operation.
tes a potentially dangerous situation, which may lead to a fatality or serious
tes a potentially harmful situation, which may lead to material damage if not
hlights useful tips and recommendations as well as information for efficient and
The TMS/TMM88 and TMS/TMM61 inclination sensors are measuring devices consist‐
ing of an e
the measuring devices are designed include recording inclinations in solar thermal
energy, photovoltaics or heavy-duty vehicle applications.
SICK AG assumes no liability for losses or damage arising from the use of the product,
either directly or indirectly. This applies in particular to use of the product that does not
conform to its intended purpose and is not described in this documentation.
2.2Incorrect use
TMS/TMM88 and TMS/TMM61 inclination sensors do not constitute safety compo‐
nent
sensors must not be used in explosion-hazardous areas. Any other use that is not
described as intended use is prohibited. Any use of accessories not specifically
approved by SICK AG is at your own risk.
WARNING
Dan
Any incorrect use can result in dangerous situations.
Therefore, take note of the following information:
■
■
lectronic sensor and integrated evaluation electronics. The tasks for which
s in ac
ger due to improper use!
Inclination sensors should be used only according to intended use specifications.
All information in these operating instructions must be strictly complied with.
SAFETY INFORMATION 2
cordance with the EC Machinery Directive (2006/42/EC). The inclination
2.3Requirements for the qualification of personnel
The personnel who work on and with the device must be suitably authorized, trained,
and suff
•
•
•
Table 1: Skilled personnel qualifications
TaskQualification
Mounting
Electrical installation
Commissioning, configura‐
t
iciently qualified. Skilled personnel refers to the following:
A member of staff who has received specialist training, which is backed up by
additional knowledge and experience.
A member of staff who knows the relevant technical terms and regulations.
A member of staff who can appraise the work assigned to them, recognize poten‐
tial hazards, and take suitable safety precautions.
hnical training
Tec
•
Knowledge of current workplace safety regulations
•
trotechnical training
Elec
•
Knowledge of the current electrotechnical workplace safety
•
regulations
Knowledge of the operation and control of the sensor in the
•
particular application
ec
hnical training
T
ion, and oper
ation
•
Knowledge of the operation and control of the sensor in the
•
particular application
8019054/14IT/2019-06-27 | SICK
Subject to change without notice
OPERATING INSTRUCTIONS | TMS/TMM88, TMS/TMM61
5
3 OVERVIEW
3Overview
Properties
■
1-dimensional inclina
■
2-dimensional inclination sensor with measuring range: 90° (X/Y)
■
High sampling rate and bandwidth
■
High resolution (0.01°)
■
High accuracy (up to 0.02°)
■
Compensated cross sensitivity
■
Configurable vibration suppression
■
Intelligent and flexibly adaptable sensor fusion algorithm for dynamic applications
tion sensor with measuring range: 360° (±180°)
(TMS/TMM88D)
■
Convenient CANopen interface
Meets the requirements of CiA DS-301, device profile CiA DSP-410
°
Baud rates from 10 kbit/s up to 1 Mbit/s
°
Automatic baud rate detection
°
Setting of node ID and baud rate via LSS service
°
■
Functions:
One or two (TMS/TMM88D) Transmit PDOs: Can be mapped dynamically
°
(RTR, cyclic, event-driven, synchronized)
SYNC consumer (sync. sending of the Transmit PDOs following receipt of a
°
SYNC message)
EMCY producer fault monitoring using heartbeat or node guarding/lifeguard‐
°
ing
■
UV-resistant, impact-resistant plastic housing or compact and rugged aluminum
housing
■
Suitable for industrial use:
Temperature range: -40 °C to +80 °C
°
Enclosure rating: IP65/67 (TMS/TMM88D: IP67/69)
°
TMS 1-dimensional inclination sensors are used to measure inclinations in the 360°
range. TMM 2-dimensional inclination sensors are used to measure inclinations in 2
±90° ranges (X/Y). To ensure high levels of accuracy, the sensors are calibrated at the
factory.
A compact and rugged design makes the sensors an ideal solution for measuring
angles in harsh environments. They are compatible for use in all manner of applications
in industry and automotive engineering. All parameter settings can be made easily via
the CANopen interface or with the PGT-12-Pro hand-held programing tool.
Areas of application
■
A
ricultural and forestry machinery
g
■
Construction machinery and special-purpose vehicles
hapter contains an extract of the technical data. For full details, see the TMS/
TMM88 (8019180), TMS/TMM88 Dynamic (8023359), TMS/TMM61 and TMM55
product information.
4.1Technical data for TMS88A/TMM88A
Table 2: Technical data for TMS88A/TMM88A
General parame‐
1)
s
ter
Number of measur‐
ing axes
Measuring ranges360°±90°
Resolution0.01°0.01°
AccuracyRange
Cross sensitivity
ated)
pens
(com
Temperature coeffi‐
cient (zer
Sampling rate80 Hz
Limit frequencyTyp. 20 Hz, 2nd order (no digital filter) / 0.1 ... 25 Hz, 8th order (with digi‐
Operating tempera‐
ture
Properties
Data rates10 k, 20 k, 50 k, 62.5 k, 100 k, 125 k, 250 k, 500 k , 800 kbit/s,
FunctionsPolling of angle, cyclic and synchronized transmission,
Electrical parameters
Supply voltage8 to 36 V DC
Current consump‐
tion
Mec
CAN connection2 x 5-pin M12 plug connectors (male connector - female connector,
Enclosure ratingIP65/67
Dimensions /
Weight
CANopen conformity
CiA DS-301, v4.2.0 Application layer and communication profile
o point)
hanical parameters
12
0...360°
-Typ. ±0.09° (±0.10%FS)
Typ. ±0.008°/K
ilter)
tal f
-40 °C to +80 °C
1 Mbit/s
omatic detection
Aut
al filter (critically damped (default) or Butterworth low pass, 8th
digit
order), configuration via object directory
<33 mA @ 24 V
looped thr
Large plastic housing: 66 mm x 90 mm x 36 mm / approx. 215 g
ough) to CiA 303-1
TECHNICAL DATA 4
TMS88ATMM88A
Typical
±0.04°
Maximum
±0.10°
Range
up to ±60°
o ±70°
up t
up to ±80°
up to ±85°
Max. ±0.45° (±0.50%FS)
Typical
±0.02°
±0.04°
±0.08°
±0.16°
Maximum
±0.05°
±0.10°
±0.20°
±0.40°
8019054/14IT/2019-06-27 | SICK
Subject to change without notice
OPERATING INSTRUCTIONS | TMS/TMM88, TMS/TMM61
7
4 TECHNICAL DATA
General parame‐
1)
ter
s
TMS88ATMM88A
CiA DS-410Device profile for inclinometer
CiA DSP-305Layer setting service (LSS) and protocols
CiA DR-303-3Indicator specification (status LED)
CiA AN-801Automatic bit-rate detection
1)
All specified angular accuracies apply after a run-in time of 10 min at 25 °C, limit frequency 0.3 Hz,