Shurflo 5907-6304 Installation Manual

HIGH FLOW SMART SYSTEM
INSTALLATION AND OPERATION INSTRUCTIONS
MODEL #: 5907-5304 (12V)
MODEL #: 5907-6304 (24V)
IMPORTANT
READ INSTRUCTIONS BEFORE INSTALLING THE HIGH FLOW SMART SYSTEM
Congratulations! You have purchased the finest fresh water dual pump system in the industry. The High Flow Smart System has been designed and engineered to provide you with “just like home” water flow up to 10 gallons per minute.
MOUNTING
Mount system within 6 feet of tank for best performance.
Mount system in a space of one cubic foot unless adequate ventilation is provided.
The system may be mounted in any position.
Choose a solid surface that will not amplify the system vibration.
The mounting feet are intended to isolate the pump from the mounting surface; over
ELECTRICAL
The pumps should be on a dedicated (individual) circuit protected by the specified fuse indicated on the motor label. NOTE: If both pumps are installed on the same circuit be aware of the total current generated by both pumps. Use the appropriate fuse size and wire gauge to protect both pumps (Total current draw x 113% = fuse size). See flow curve on page #2 for reference.
A U/L approved marine duty switch (ignition protected) is recommended, and must interrupt current flow on the positive (+ red) lead.
Smart Sensor 5.7 pump draws 15 milliamps when pump switch is on, even when pump is not running.
WARNING: SMART SENSOR 5.7 12V PUMPS
Test incoming power with a multimeter to check voltage polarity (red = +). Red pump wire MUST be connected to positive power or permanent damage to controller will result!!! Failures of these type are not covered under product warranty.
SYSTEM DIMENSIONS:
911-1005 Rev C 12/08 ECO #: 16135 Page 1 of 4
PLUMBING Reducing unnecessary restrictions to the inlet and the outlet tubing will allow the
system to run freely, maximizing performance, quietness and eliminate the possibility of cavitation (starving the pumps).
Installation of a 40 mesh strainer to each pump, such as SHURflo model 254 is
recommended to prevent debris from entering the pumps.
SHURflo quick-connect fittings provide easy installation and removal if required. The fittings
are designed with dual o-rings, creating a seal when snapped into place.
System may flow better with 3/4” line feeding the pumps.
Dual System Performance 5907-5304 12V
10
9 8 7 6 5 4
Flow (gpm)
3 2 1 0
0 10 20 30 40 50 60
Pressure (psi)
24 22 20 18 16 14 12 10 8 6 4 2 0
Current (amps)
Flow (gpm) Both Pumps Amps (Both Pumps) Amps (Smart Sensor) Amps (X-ProBlaster)
Dual System Performance 5907-6304 24V
10
9
8
7
6
5
4
Flow (gpm)
3
2
1
0
0 10 20 30 40 50 60
Pressure (psi)
Flow (gpm) Both Pumps Amps (Both Pumps) Amps (Smart Sensor) Amps (X-ProBlaster)
12
10
8
6
4
Current (amps)
2
0
911-1005 Rev C Page 2 of 4