Shurflo 359-101-30 Installation Manual

SHURflo BILGE SWITCH
INSTALLATION AND OPERATION INSTRUCTIONS
MODEL #: WITH OUT CAGE: OEM: 359-101-30 / AM: 359-111-30
MODEL #: WITH CAGE: OEM: 359-101-40 / AM: 359-111-40
FEATURES:
NON MERCURY MECHANICAL SWITCH 3’ OF TINNED WIRE EASY SNAP INTO BASEPLATE DESIGN
MANUAL TEST FEATURE OPTIONAL CAGE AVAILABLE 12A MAX AT 12V, 6A MAX AT 24V 3 YEAR WARRANTY
Installation: Location
Locate pump at deepest position in the bilge. Keep away from high heat source; engine, etc. Mount to hull or pad with stainless steel screws.
Mounting
For best performance, switch should be mounted horizontal. Maximum mounting angle is 20° from vertical.
DO NOT DRIVE SCREWS THROUGH HULL!! Operation
Switch will energize the bilge pump when water level reaches 1-3/4” (44mm) and will turn the bilge pump off when water level falls to 3/4” (19mm). SHURflo recommends to install the Bilge switch cage for optimal performance.
Cage (Optional)
Manual Test Lever
Electrical: Wire Leads
Use 16 AWG wire. Installation over 20 feet, use 14 AWG wire. Wire is tinned to prevent corrosion. To reduce water wicking corrosion through wires, make all connections with water proof connectors above all splashing bilge water.
Wiring tips
Twist wires together to reduce RFI (radio interfer­ence)
Always use waterproof splices and connectors. Make connections above water line, if possible.
Use recommended fuse stated on bilge pump label.
Fuse MUST be between battery and panel switch.
Some panel switches may have a fuse in them.
WARNING
WATER. PLEASE TAKE APPROPRIATE MEASURES TO PREVENT DISCHARGING OIL AND CHEMICALS. ALWAYS TEST PUMP AND SWITCH BEFORE OPERATION.
DO NOT PUMP OIL, DIESEL FUEL, GASOLINE OR OTHER FLAMMABLE LIQUIDS OVERBOARD. THIS SWITCH DOES NOT PREVENT THE DISCHARGE OF OIL OR CHEMICALS INTO THE
WARNING
DIMENSIONS WITH CAGE DIMENSIONS WITH OUT CAGE
KEEP ALL WIRE CONNECTIONS ABOVE THE HIGHEST WATER LEVEL. WIRES SHOULD BE SEALED WITH A WATER­PROOF MARINE SEALANT TO PRE­VENTCORROSION!
911-1004 Rev E 12/08 ECO #: 16135 Page 1 of 2
NOTE:
If replacing the SHURflo Piranha Bilge switch (359-101-00 or 359-111-00) with SHURflo Bilge switch (359-101-30 or 40) use the following procedure for installation.
Connect one of the BROWN wires from the Float Switch and the Positive (+) from the Battery to the Middle Pin of the three way switch (Panel Switch).
Connect the other BROWN wire from the Float Switch and the BROWN (+) wire from the pump to the Automatic side of the three way switch (Panel Switch).
Connect the black wire (-) from the pump to the Battery ground.
NOTE: The manual side of the three way switch (Panel Switch) will be disabled. Contact SHURflo customer service for questions.
Favor de referirse a www.shurflo.com para instrucciones de la instalación del producto y su operación, disponible en varios idiomas.
Mehrsprachige Hinweise zu Installation und Betrieb des Produktes finden Sie unter www.shurflo.com
Fare riferimento al sito www.shurflo.com per manuali multilingue di installazione ed utilizzo prodotti.
Veuillez vous réferer au site www.shurflo.com pour l'installation produit multilingue ainsi que pour le mode d'emploi.
Please refer to www.shurflo.com for multi-lingual product installation and operating instructions'
LIMITE WARRANTY:
SHURflo warrants its SHURflo bilge pump switches to be free of defects in material and workmanship under normal use for a period of three years from the date of manufacture, as indicated on the switch label. Returns are to be shipped to SHURflo. This warranty is only a representation of the complete marine products limited warranty. Outline by Service Bulletin # 1050. Call or write for a copy.
SHURflo reserves the right to update specifications, prices, or make substitutions.
SHURflo, LLC Headquarters
5900 Katella Avenue Cypress, California 90630 Phone (562) 795-5200 Ÿ Toll Free (800) 854-3218 Fax (562) 795-7564
911-1004 Rev E © 2008 SHURflo, LLC All Rights Reserved
SHURflo, LLC East
52748 Park Six Court Elkhart, Indiana 46514-5427 Phone (562) 795-5200 Ÿ Toll Free (800) 854-3218 Fax (574) 264-2169
SHURflo Europe, Middle East, Africa Pentair Water Belgium bvba,
Industriepark Wolfstee, Toekomstlaan 30 B-2200 Herentals, Belgium Phone +32-14-283500Ÿ Fax +32-14-283505
Page 2 of 2
Loading...