Shurflo 358-100-00 Installation Manual

358™SHURflo BILGE PUMP
Installation and Operation Instructions
MOUNTING
Locate the pump in the deepest position in the bilge. Keep away from high heat source.
Mount quick disconnect bracket to bulkhead or stringer with #10 S.S. screws. Do not drive
screws through hull.
Route smooth I.D. discharge tubing to a thru-hull fitting well above the water line . Avoid any sagging or loops in the tubing. Tubing must go up from the pump to the thru-hull fitting.
Position the discharge
Avoid
potencial
air lock
Water
Level
Incorrect position for discharge port.
Avoid sags, sharp bends, etc.
port "Up" so not to trap air!
All connections should have double clamps for added security.
ADVANCED BILGE PUMP FEATURES
Anti-Airlock
Tough Nylon Housing
Tinned 6’ Wire Assembly
Water Cooled Motor
Submersible
Ignition Protected
ISO 8846, ABYC, NMMA Type Accepted, CE
EXPLODED VIEW
Remove all 7 screws for cleaning if necessary.
Baseplate tabs press in for easy removal.
ELECTRICAL
NOTE: Typical circuit only, consult boat wiring diagram.
black
12 VDC bat.
Ref. specs.
*
for fuse size
*UL approved marine duty, ignition protected, single pole double throw switch with center off. Rated at or above 15 amps.
red
brown (+)
Automatic-on
*
Optional
Float Switch
* not supplied
ELECTRICAL WIRE:
Use 16GA wire for all circuits. If installation is over 20 feet, use 14GA wire. Brown pump wire must be hooked to positive power for maximum flow. Wire is tinned to prevent corrosion. PANEL SWITCH: Attach all wires to UL Marine approved duty switch with auto-off-manual, rated at or above 15 amps. FUSE: Install a fuse per pump label specifications . CONNECTIONS: Wire connections should be made above the highest possible water level. Seal wire connections to prevent corrosion and electrolysis.
OPERATION DO NOT RUN PUMP DRY. ALWAYS TEST PUMP AND SWITCH BEFORE LEAVING DOCK.
Manual-on
brown (+)
black
911-742 Rev F 12/08 ECO #: 16135 Page 1 of 2
OPERATION MANUAL MODE: To turn pump on, turn manual power switch on. If pump does not turn on, turn switch off, check power,
fuses, connections, wires. Retry. If pump does not turn on, check pump motor.
FLOW GPM [LPM] TECHNICAL DATA
Name Voltage Model #: 0 Ft [0 M] 3 Ft [1 M]
1500 *12 V 358-000-00 1800 [6813] 1700 [6434]
2000 *12 V 358-010-00 2200 [8327] 2000 [7570]
1500 24 V 358-100-00 1800 [6813] 1700 [6434]
2000 24 V 358-110-00 2200 [8327] 2000 [7570]
* Specifications given at design voltage 13.6 VDC per ABYC recommendations.
Pump Power leads: 6 ft. [1.8 M] #16 tinned stranded copper wire to minimize corrosion. Positive (+) brown; Ground (–) black. Temperature limits: 33ºF—140ºF [0ºC—60ºC]. All models rated for continuous duty. Approvals: Ignition Protected, ISO 8846, ABYC, NMMA Type Accepted, CE.
WARNING
Do not pump oil, diesel fuel, gasoline or other flammable liquids with this pump. This pump does not prevent the discharge of oil or other chemicals into the water. Please take appropriate measures to prevent discharging oil or other chemicals and safeguard the environment. Always disconnect power before servicing pump. Always use fuse size specified in specifications. These bilge pumps are designed to evacuate standing bilge water only. These pumps may not prevent boat sinkage due to storms, rough weather, unsafe boating, improper installation procedures or hull damage.
6 Ft [2
[6056] 14 [4.27] 8 10 1-1/8" 7 1/4" X 6"
[7191] 18 [5.5] 10 15 1-1/8" 7 1/4" X 6"
[6056] 14 [4.27] 4 6 1-1/8" 7 1/4" X 6"
[7191] 18 [5.5] 5 8 1-1/8" 7 1/4" X 6"
M]
1600
1900
1600
1900
Max Head
Ft [M] Max Amps Fuse Outlet Port Dimensions
SYMPTOM CHECK FOR
No water pumped/
Pump not running
Reduction in water
flow
Low Flow
Blown fuse. Wire connections. Impeller or float switch plugged with debris. Impeller/screen plugged with debris. Pinch/clogged discharge tubing. Discharge tubing sagging
below pump causing air lock. Tubing must go up from pump to thru-hull fitting. Low voltage to pump; check battery/wire connections. Polarity reversed; check wiring. Use only smooth bore (I.D.) discharge tubing. Is thru-hull fitting I.D. smaller than pump discharge port?
LIMITED WARRANTY
SHURflo warrants its 358 SHURflo bilge pumps to be free of defects in material and workmanship under normal use for a period of three (3) years from date of purchase. In absence of proof of purchase, the warranty is three (3) years from the date of manufacture indicated on the pump housing. Returns are to be shipped prepaid to SHURflo. This warranty is only a representation of the complete Marine Products Limited Warranty outlined by Service Bulletin #1050. Please contact SHURflo for complete warranty information.
Favor de referirse a www.shurflo.com para instrucciones de la instalación del producto y su operación, disponible en varios idiomas.
Mehrsprachige Hinweise zu Installation und Betrieb des Produktes finden Sie unter www.shurflo.com
Fare riferimento al sito www.shurflo.com per manuali multilingue di installazione ed utilizzo prodotti.
Veuillez vous réferer au site www.shurflo.com pour l'installation produit multilingue ainsi que pour le mode d'emploi.
Please refer to www.shurflo.com for multi-lingual product installation and operating instructions'
SHURflo reserves the right to update specifications, prices, or make substitutions.
SHURflo, LLC Headquarters
5900 Katella Avenue Cypress, California 90630 Phone (562) 795-5200 Ÿ Toll Free (800) 854-3218 Fax (562) 795-7564
SHURflo, LLC East
52748 Park Six Court Elkhart, Indiana 46514-5427 Phone (562) 795-5200 Ÿ Toll Free (800) 854-3218 Fax (574) 264-2169
SHURflo Europe, Middle East, Africa
Pentair Water Belgium bvba,
Industriepark Wolfstee, Toekomstlaan 30 B-2200 Herentals, Belgium Phone +32-14-283500Ÿ Fax +32-14-283505
911-742 Rev F © 2008 SHURflo, LLC All Rights Reserved
Patent #: 7371045 Page 2 of 2
Loading...