Model 355 Installation Instructions
BILGE PUMP FEATURES
• Quick-disconnect base plate for easy installation.
• Nylon Impeller.
• Submersible.
• 3 ft. tinned power leads to insure operation in the wettest conditions.
• Water cooled motor to insure long life.
• Easy transom mount base plate.
INSTALLATION
LOCATION: Locate pump at deepest position in the bilge. Keep away from high heat source; engine, etc.
MOUNTING: Mount quick-disconnect bracket to hull or pad with stainless steel screws. Mount switch if
equipped. Do not drive screws through hull! TUBING: Route smooth I.D. discharge tubing to a thru-hull
fitting well above the water line. AVOID AIRLOCK & MAXIMIZE PERFORMANCE: Avoid any sagging or
loops in the tubing. Tubing must go up from pump to thru-hull.
ELECTRICAL
Use 16GA wire for all circuits. If installation is over 20 feet, use 14GA wire. Brown pump wire must be
hooked to positive power for maximum flow. Wire is designed to prevent corrosion. PANEL SWITCH:
Attach all wires to UL Marine approved duty switch with auto-off-manual, rated at or above 10 amps.
FUSE: Install a fuse per pump label specifications . CONNECTIONS: Wire connections should be made
above highest possible water level. Seal wire connections to prevent corrosion and electrolysis.
OPERATION
DO NOT RUN PUMP DRY. ALWAYS TEST PUMP AND SWITCH BEFORE LEAVING DOCK.
MANUAL MODE: When brown wire from switch is not hooked up, the pump float switch is bypassed. To
turn pump on, turn switch on. If pump does not turn on, turn switch off, check power, fuses, connections,
wires. Retry. If pump does not turn on, check pump motor. When the water level is above the float switch,
the pump will automatically start. If the float becomes jammed with debris, the pump will NOT STOP
running. Turn the pump switch to the OFF position. Remove the debris. Reset switch to the automatic or
manual ON position. Test. SWITCH TEST: Turn power ON to pump switch. Use a quarter or flat head.
Fuse
12VDC
Battery
To
Pump
Panel Switch
Manual
Brown
Brown
Brown
To
Switch
Typical Electrical Installation with Pump and Switch
connections with
waterproof
911-758 Rev D 12/08 ECO #: 16135 Page 1 of 2
CLEANING:
Impeller: Snap pump out of base plate by pressing in the tabs. Clean debris and snap back in
place. Test unit.
Switch: Remove debris or build-up. Reinstall switch and test unit.
Switch test: Turn power on to pump switch.
WIRING:
Check all wire connections regularly. Repair sign of corrosion.
Repair Kit for all
models: 94-750-00
FLOW GPM [LPM] TECHNICAL DATA
Model #: 0 ft [0 M] 3 ft [1 M] 6 ft [2 M] Max Head Ft [M] Max Amps Fuse Outlet Port Dimensions
355-020-10 380 [1438] 340 [1157] 240 [817] 7.5 [2.2] 1.7 2.5 3/4" 4-1/2" X 3"
355-010-10 500 [1892] 430 [1464] 270 [918] 7.5 [2.2] 1.8 2.5 3/4" 4-1/2" X 3"
355-110-10 700 [2649] 600 [2043] 500 [1702] 10 [3] 3.2 5 3/4" 4-1/2" X 3"
355-100-10 1000 [2649] 840 [2861] 650 [2214] 11 [3.3] 3.4 6 1-1/8" 4-1/2" X 3"
Specifications given at design voltage 13.6 VDC per ABYC recommendations.
Pump Power leads: 3 ft. [0.9 M] #16 tinned stranded copper wire to minimize corrosion. Positive (+) brown; Ground (–) black
Switch Leads (If equipped with SHURflo Piranha Switch): Automatic (+) brown; Manual (+) brown & white; Ground (--) black
Temperature limits: 33ºF—140ºF [0ºC—60ºC]. All models rated for continuous duty.
Approvals: Ignition Protected, ISO 8846, ABYC, NMMA Type Accepted, CE
TROUBLESHOOTING
Symptoms Check For
No water pumped
Pump not running
Reduced water flow
Reset pump switch. Blown fuse. Reversed polarity damaged switch board.
Wire connections. Impeller or float switch plugged with debris.
Impeller/screen plugged with debris. Pinched/clogged discharge tubing. Discharge tubing sagging below
pump causing air lock (Tubing MUST go "UP" from pump to through hull fitting). Low voltage to pump;
check. Battery/wire connections.
Low flow Polarity reversed (on pump only); check wiring. Use smooth bore (I.D.) discharge tubing only.
Is through hull fitting I.D. smaller than pump discharge port?
Runs continuously Check boat for leaks; Clean accumulated debris from float mechanism.
Do not pump oil, diesel fuel, gasoline or other flammable liquids with this pump.
WARNING
This pump does not prevent the discharge of oil or other chemicals into the water. Please take appropriate
measures to prevent discharging oil or other chemicals and safeguard the environment. Always disconnect
power before servicing pump. Always use fuse size specified in specifications. These bilge pumps are
designed to evacuate standing bilge water only. These pumps may not prevent boat sinkage due to storms,
rough weather, unsafe boating, improper installation procedures or hull damage.
LIMITED WARRANTY
SHURflo warrants its SHURflo™ series bilge pumps to be free of defects in material and workmanship under normal use for a
period of three (3) years from the date of manufacture, as indicated on the pump label. Returns are to be shipped prepaid to
SHURflo. This warranty is only a representation of the complete marine products limited warranty, outlined by Service Bulletin
#1050. Call or write for a copy.
Favor de referirse a www.shurflo.com para instrucciones de la instalación del producto y su operación, disponible en varios idiomas.
Mehrsprachige Hinweise zu Installation und Betrieb des Produktes finden Sie unter www.shurflo.com
Fare riferimento al sito www.shurflo.com per manuali multilingue di installazione ed utilizzo prodotti.
Veuillez vous réferer au site www.shurflo.com pour l'installation produit multilingue ainsi que pour le mode d'emploi.
Please refer to www.shurflo.com for multi-lingual product installation and operating instructions'
SHURflo reserves the right to update specifications, prices, or make substitutions.
SHURflo, LLC Headquarters
5900 Katella Avenue
Cypress, California 90630
Phone (562) 795-5200 Ÿ Toll Free (800) 854-3218
Fax (562) 795-7564
911-758 Rev D
© 2008 SHURflo, LLC All Rights Reserved
SHURflo, LLC East
52748 Park Six Court
Elkhart, Indiana 46514-5427
Phone (562) 795-5200 Ÿ Toll Free (800) 854-3218
Fax (574) 264-2169
SHURflo Europe, Middle East, Africa
Pentair Water Belgium bvba,
Industriepark Wolfstee, Toekomstlaan 30
B-2200 Herentals, Belgium
Phone +32-14-283500Ÿ Fax +32-14-283505
Patent #: 6715994 Page 2 of 2