Shure orporated PA421SWB User Manual

Page 1
PA421SWB Antenna Combiner
2008 Shure Incorporated Printed in U.S.A. 27A12082 (Rev. 1)
PA42 1
PS MAntennaCombiner
470-870 Mhz
INPUTSIGNA L
ACTIVE COMBINER
1
2
3
4
50OHMS
POW ER
PA421SWB
ANTENNA COMBINER
Page 2
2
! IMPORTANT SAFETY INSTRUCTIONS !
1. READ these instructions.
2. KEEP these instructions.
3. HEED all warnings.
4. FOLLOW all instructions.
5. DO NOT use this apparatus near water.
6. CLEAN ONLY with dry cloth.
7. DO NOT block any ventilation openings. Install in accordance with the manu­facturer's instructions.
8. DO NOT install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. DO NOT defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the third prong are provided for your safety. If the provided plug does not fit into your out­let, consult an electrician for replacement of the obsolete outlet.
10. PROTECT the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. ONLY USE attachments/accessories specified by the manufacturer.
12.
13. UNPLUG this apparatus during lightning storms or when unused for long periods of time.
14. REFER all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is dam­aged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
15. DO NOT expose the apparatus to dripping and splashing. DO NOT put objects filled with liquids, such as vases, on the apparatus.
16. The MAINS plug or an appliance coupler shall remain readily operable.
17. The airborne noise of the apparatus does not exceed 70dB (A).
18. Apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a protective earthing connection.
19. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
20. Do not attempt to modify this product. Doing so could result in personal injury and/or product failure.
USE only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
WARNING:
Voltages in this equipment are hazardous to life. No user-serviceable parts inside. Refer all servicing to qualified service personnel. The
safety certifications do not apply when the operating voltage is changed from the factory setting.
OVERVIEW
The Shure PA421SWB Antenna Combiners actively combine antenna outputs from up to four PSM wireless transmitters to a single antenna, improving RF performance and reducing rack clutter.
INSTALLATION
Before installing, set the front panel power switch to OFF. 1. (See Figure 1) Using the supplied power cable connect the unit to an AC power source.2. To use the device set the front panel power switch to ON. The power light will illuminate.3. Before disconnecting the unit from the AC power source, or when not in use, power the unit OFF. 4.
PA42 1
PSMAntenna
47
0-
870 Mhz
MAINOUT
INPUTSIGNAL
ACTIVE COMBINER
1
2
3
4
50OHMS
POWER
Combiner
ON/OFF
POW
ER
ON/OFF
4XJUDI0GG
Figure 1
Front Panel Switch Off
PA421SWB Benefits
Reduction of intermodulation artifacts for cleaner RF environment • and more channels on air.
Simplified antenna placement.•
Power distribution.•
Page 3
3
4-TO-1 COMBINING FOR PSM TRANSMITTERS
Using the supplied BNC-BNC cables, connect the Antenna Output 1. of each transmitter to the Antenna Inputs of the PA421SWB (See Figure 2). Attach an antenna to the MAIN Out of PA421SWB. For wideband 2. applications, use PA805SWB directional antenna (Figure 1). Connect the PA421SWB to a power outlet using one of the supplied 3. power cables. The PA421SWB contains a universal power supply to operate anywhere in the world. If you have a Shure PSM system that has the same power input 4. connectors as the PA421SWB power ouputs, such as the PSM400, connect the PSM system to the PA421SWB via the supplied power cables (see figure 2). This replaces the need for an external power supply.
NOTE: The PA421SWB supplied power is 15 V and up to 660 mA.
®
PA 805WB
Figure 2
NOTE: When the PA421SWB is powered on, the input signal indicators (1-4) on the front panel will illuminate if an active transmitter is connected to the corresponding input (1-4) on the back panel (Figure 2).
LICENSING
Changes or modifications not expressly approved by Shure Incor­porated could void your authority to operate the equipment. Licens­ing of Shure wireless microphone equipment is the user’s respon­sibility, and licensability depends on the user’s classification and application, and on the selected frequency. Shure strongly urges the user to contact the appropriate telecommunications authority concern­ing proper licensing, and before choosing and ordering frequencies.
THIS RADIO EQUIPMENT IS INTENDED FOR USE IN PROFESSIONAL
ENTERTAINMENT AND SIMILAR APPLICATIONS.
NOTE: THIS EQUIPMENT MAY BE CAPABLE OF OPERATING ON SOME FREQUENCIES NOT AUTHORIZED IN YOUR REGION. PLEASE CONTACT YOUR NATIONAL AUTHORITY TO OBTAIN INFORMATION ON AUTHORIZED FREQUENCIES FOR WIRELESS MICROPHONE PRODUCTS IN YOUR REGION
Licensing: Note that a ministerial license to operate this equipment may be required in certain areas. Consult your national authority for possible requirements.
OPERATION OF THIS DEVICE IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE INTERFERENCE, AND
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE, INCLUDING INTER­FERENCE THAT MAY CAUSE UNDESIRED OPERATION OF THE DEVICE.
SPECIFICATIONS
RF Carrier Frequency Range
470-952 MHz
System Gain
+0/-5 dB
Input AC Line Voltage
100-240 Vac, 50/60 Hz
Maximum Input Line VA
100 VA
Maximum Current Drain
0.42-1.0 Amperes
(Amperes = 100 VA/Input AC Line Voltage)
Maximum RF Input Power
24 dBm (250 mW) per channel
Input Signal Indicator Threshold
+4 dBm (2.5 mW), +2 dBm (1.6 mW) typical
Impedance
50 W nominal
Operating Temperature Range
0× F (-18 × C) to +135× F (+57 × C)
Overall Dimensions
43.4 mm high x 398.8 mm wide x331.5 mm deep (1 11/16 in. H x 15 11/16 in. W x 13
1/2 in. D)
Net Weight
4.53 Kg
(10 lbs unpackaged, without power and RF
cables)
Input/Output Connector Type
BNC-type 4 input, 1 output ACTIVE
Power Output
15 VDC, 660 mA each
NOTE: Electrical safety approval is based on a maximum ambient temperature of 35°C.
FURNISHED ACCESSORIES
(4) 2 ft. Coaxial Cable (RG58C/U)
UA802
(4) 2 ft. Output Power Cable
95B8420
120 VAC Power Line Cord
95A8389
230 VAC Power Line Cord
95A8247
240 VAC Power Line Cord (U.K.)
95A8713
PA421SWB Frequency Range
470-1100 MHz
Wideband Unidirectional Antenna (470-952 MHz)
PA805SWB
10 ft. Coaxial Cable (RG-8X/U)
PA725
25 ft. Coaxial Cable (RG-8X/U)
UA825
50 ft. Coaxial Cable (RG-8X/U)
UA850
Wide Band Omnidirectional Antenna
UA860SWB
Helical Antenna
HA-8089 (480-900 MHz)
HA-8241(944-952 MHz)
OPTIONAL ACCESSORIES
CERTIFICATIONS
PA421SWB: Certified to FCC Part 74 (FCC ID No. DD4PA421SWB). Certified in Canada by IC to RSS-123 AND RSS-102 (Certification No. IC 616A-PA421SWB). UL LISTED to UL60065, 7th Edition and cUL LISTED to CAN/CSA E60065-00. Meets the Essential Requirements of the European R&TTE Directive 99/5/EC, eligible to bear CE mark. Meets EMC requirements of EN 301 489 Parts 1 and 9 and is GS­Certified to EN EN60065, 7th Edition. Conforms to Australian EMC
requirements, eleigible to bear C-Tick mark (N108)
N108
.
Page 4
www.shure.com
United States:
Shure Incorporated 5800 West Touhy Avenue Niles, IL 60714-4608 USA
Phone: 847-600-2000 Fax: 847-600-1212 Email: info@shure.com
©2008 Shure Incorporated
Europe, Middle East, Africa:
Shure Europe GmbH Wannenäckestr. 28, 74078 Heilbronn, Germany
Phone: 49-7131-72140 Fax: 49-7131-721414 Email: info@shure.de
Asia, Pacific:
Shure Asia Limited Unit 301, 3rd Floor Citicorp Centre 18, Whitfield Road Causeway Bay, Hong Kong
Phone: 852-2893-4290 Fax: 852-2893-4055 Email: info@shure.com.hk
Canada, Latin America, Caribbean:
Shure Incorporated 5800 West Touhy Avenue Niles, IL 60714-4608 USA
Phone: 847-600-2000 Fax: 847-600-6446 Email: international@shure.com