Shure R115 User Manual

DYNAMIC MICROPHONE REPLACEMENT CARTRIDGE
The Shure Model R115 is a replacement cartridge for both the
Shure Model 55SH Series II UNIDYNE
SPHERE
®
A dynamic microphones. When properly installed in the microphone, the R115 will provide performance equal to that of the original cartridge.
To install the R115 in either microphone, proceed as follows:
55SH SERIES II
1. Remove the four 6-32 x 1/4-inch Phillips head screws securing
the die-cast case front to the die-cast case back. Remove the case front.
2. Remove the four 4-40 x 5/16-inch round head screws and
lockwashers securing the cartridge assembly to the case back.
3. Carefully withdraw the black plastic cartridge assembly from
the case back, taking care not to stretch or break the three leads.
4. Remove the four 7-19 self-tapping Phillips head screws from
the rear of the cartridge assembly and remove the rear cover from the housing.
5. Using a low-wattage soldering iron, unsolder the three leads
from the cartridge to be replaced.
6. Remove the old cartridge. Keep the aluminum retaining ring.
7. Place the aluminum retaining ring over the rear of the R115
replacement cartridge, and carefully solder the three leads to the cartridge (see Figure 1).
CARTRIDGE
CODED TERMINAL
55SH INTERNAL CONNECTIONS
8. Carefully insert the cartridge and ring in the black plastic hous-
ing, replace the rear cover, and secure it with the four self-tap­ping screws previously removed.
9. Insert the cartridge assembly in the case back and secure it
with the four round head screws and lock-washers previously removed. Engage the two lower (toward switch) screws first to align the assembly.
10. Replace the case front and secure it with the four Phillips head
screws previously removed.
SWITCH XLR
BLACK
YELLOW
BLUE
FIGURE 1
and 586 Series UNI-
CONNECTOR
BLACK
YELLOW
2
3
1
Model R115 User Guide
Replacement Cartridge
586 SERIES
1. Grasping the ring (nameplate) of the screen and grille assem­bly, unscrew (turn counterclockwise) and remove the assem­bly.
2. Carefully withdraw the cartridge from the handle. Take care not to break or stress the leads from the cartridge.
3. Using a low-wattage soldering iron, unsolder the three leads from the cartridge to be replaced.
4. Carefully solder the three leads to the R115 replacement car­tridge (see Figure 2).
CARTRIDGE
CODED TERMINAL
CARTRIDGE SWITCH CONNECTOR
CODED TERMINAL
5. Carefully insert the R115 cartridge in the handle, taking care not to stress or crimp any of the three leads. Seat the cartridge firmly in the handle.
6. Screw (turn clockwise) the screen and grille assembly on the handle.
SHURE Incorporated http://www.shure.com United States, Canada, Latin America, Caribbean: 5800 W. Touhy Avenue, Niles, IL 60714-4608, U.S.A. Phone: 847-600-2000 U.S. Fax: 847-600-1212 Intl Fax: 847-600-6446 Europe, Middle East, Africa: Shure Europe GmbH, Phone: 49-7131-72140 Fax: 49-7131-721414 Asia, Pacific: Shure Asia Limited, Phone: 852-2893-4290 Fax: 852-2893-4055
TRANSFORMER
YELLOW
SWITCH CONNECTOR
CASE GROUND
BLACK
WHITEGREEN
WHITE
SWITCH SHOWN IN “OFF” POSITION
MODEL 586SA
BLACKBLACK
BLUE
WHITE
WHITE
BLUE
CASE GROUND
SWITCH SHOWN IN “OFF” POSITION
MODEL 586SB
INTERNAL CONNECTIONS
FIGURE 2
BLACK
12
3
12
3
©2005, Shure Incorporated
27C2930 (Rev. 9)
Printed in U.S.A.