Over 80 years of audio experience has contributed to making the KSM9
one of the finest microphones available.
If you have any questions not answered in this booklet, please contact Shure
Applications Engineering at 847-600-8440, Monday through Friday, from 8:00am to
4:30 pm, CST. In Europe, call 49-7131-72140. Our web address is www.shure.com.
1
KSM9
KSM9
GENERAL DESCRIPTION
The Shure
KSM9 is a dual-pattern (cardioid and supercardioid) handheld
condenser microphone. Designed expressly for live vocal performance
applications, the KSM9 removes the boundary between the studio and stage,
offering the finest and clearest performance on modern high-end touring
systems. The large dual diaphragm provides consistent polar response across
the entire frequency range, for higher gain-before-feedback and minimal
proximity effect for clear vocal reproduction.
FEATURES
• Dual 3/4” gold layered, low mass Mylar
®
diaphragms provide superior
frequency response.
• Dual polar patterns (cardioid and supercardioid) for maximum flexibility in a
wide variety of performance applications.
• Class A, discrete, transformerless preamplifier provides transparent,
extremely fast transient response with no crossover distortion and minimal
harmonic and intermodulation distortion.
• Advanced suspension shock mount system that isolates cartridge from
handling and stand noise.
• Premium electronic components, including gold-plated internal and external
connectors.
• Three-stage grille reduces “pop” and breath noise.
PERFORMANCE CHARACTERISTICS
• Smooth, pronounced high-end response
• Upper mid-range sounds accurate and articulate without sounding harsh
• Reduced proximity effect
• Focused low-end response
2
MODEL VARIATIONS
Wired ModelsDescription
KSM9/SLDual-Pattern (Cardioid/Supercardioid)
KSM9/CGDual-Pattern (Cardioid/Supercardioid)
Handheld Vocal Microphone, Champagne
Handheld Vocal Microphone, Charcoal
Gray
APPLICATION AND PLACEMENT
The KSM9 provides superior sound in any application that demands reference
quality audio. The KSM9 is the ideal microphone for touring musicians,
regardless of venue.
The frequency response of the two patterns on the KSM9 sound nearly
identical, making it possible to choose a pattern most suitable for a given
application. The cardioid pick-up pattern provides excellent sound isolation
and gain before feed-back with minimal off-axis coloration. The narrower
supercardioid pick-up pattern provides maximum sound isolation and is ideal
for applications in which there are high levels of ambient noise, or where
multiple instruments or vocalists are close to each other.
General Rules for Microphone Use
1. Mute all microphone channels prior to plugging or unplugging XLR
cables, switching polar patterns, applying pads, high pass filters or
applying phantom power.
2. Aim the microphone toward the desired sound source and away from
unwanted sources.
3. Place the microphone as close as is practical to the desired sound
source.
4. Keep the distance between microphones at least three times the distance
from each source to its microphone.
5. Place microphones as far as possible from reflective surfaces.
6. Use the fewest number of microphones as is practical.
7. If necessary, add a windscreen when using the microphone outdoors.
8. Do not cover any part of the grille with your hand.
3
USING THE KSM9
Proximity Effect
In general, unidirectional microphones progressively boost bass frequencies
up to 10 to 15 dB (at 100 Hz) as the microphone approaches 6 mm (1/4 in.)
from the sound source. This phenomenon, known as proximity effect, delivers
a warmer, more powerful sound. Unfortunately, it usually requires the vocalist
to maintain a consistent distance from the microphone in order to avoid
changing the low frequency response.
The dual-diaphragm design of the KSM9, however, provides vocalists with
more consistent low-end response when adjusting microphone distance
during performances. And the gradual, low-frequency roll-off of the KSM9
minimizes the distorted or “boomy” sound that typically results from very close
proximity.
Wind Noise
The KSM9 has an integral wind and pop filter which provides excellent
protection against most wind and breath noise. An optional foam windscreen
is available for use in conditions such as high winds or close proximity to a
“problem” vocalist.
TWO POSITION SWITCH
FIGURE 1
Cardioid. Is most sensitive to sounds directly in front of the microphone
and is least sensitive to those in back. Cardioid is the most commonly used
pattern in live sound applications. Its slightly wider pick-up pattern is more forgiving at picking up off-axis sound. See Figure 3.
Supercardioid. The narrower pattern provides greater rejection of off-
axis sound and maximun gain before feedback. The supercardioid pattern is
ideal for use in loud environments or applications in which sound sources are
very close to each other. See Figure 5.
Phantom Power
The KSM9 requires phantom power and performs optimally with a 48 Vdc supply (IEC-268-15/DIN 45 596). However, it will operate with slightly decreased
headroom and sensitivity with power supplies as low as 11 Vdc.
4
Impedance
A minimum load impedance of 800 ohms should be used for maximum signal
handling and minimum distortion. The impedance may be as low as 150 ohms,
but a reduction in output level and output clipping level will result.
SPECIFICATIONS
Cartridge TypeCondenser (Electret Biased)
Frequency Response50 to 20,000 Hz
Output Impedance150 Ω (actual)
Phantom Power
Current Drain5.2 mA typical at 48 Vdc
Common Mode Rejection>60 dB, 50 Hz to 20 kHz
PolarityPositive pressure on front diaphragm produces
Directional Polar PatternsCardioid
Sensitivity
(typical; at 1000 Hz;
1 Pa = 94 dB SPL)
Self-noise
(typical, equivalent SPL;
A-weighted, IEC 651)
Maximum SPL @ 1000 Hz
2500 Ω load
1000 Ω load
Output Clipping Level*
2500 Ω load
1000 Ω load
Dynamic Range
2500 Ω load
1000 Ω load
Signal to Noise ratio**72 dB
Dimensions and Weight
*100 Hz to 20 kHz;THD < 1%.
**S/N ratio is difference between 94 dB SPL and equivalent SPL of self-noise A-weighted.
positive voltage on output pin 2 relative to pin 3
(See Figure 3)
49 mm (1 15/16 in.) maximum body diameter, 191 mm
(7.5 in.) long; 300 grams (10.6 oz). See Figure 6.
(See Figures 2, 4)
2 and 3
Supercardioid
(See Figure 5)
-51 dBV/Pa
22 dB
152 dB
152 dB
6.7 dBV
6.0 dBV
130 dB
130 dB
5
CARDIOID RESPONSE GRAPHS
FIGURE 2. TYPICAL CARDIOID FREQUENCY RESPONSE
180°
150°
150°
120°
90°
60°
30°
120°
120°
90°
–20 dB
–15 dB
–10 dB
–5 dB
0
250 Hz
500 Hz
1000 Hz
90°
60°
60°
30°
FIGURE 3. TYPICAL CARDIOID POLAR PATTERN
SUPERCARDIOID RESPONSE GRAPHS
180°
150°
150°
120°
–20 dB
–15 dB
–10 dB
–5 dB
30°
90°
60°
30°
0
2500 Hz
6400 Hz
10000 Hz
FIGURE 4. TYPICAL SUPERCARDIOID FREQUENCY RESPONSE
180°
180°
150°
150°
150°
150°
120°
120°
120°
90°
90°
60°
60°
30°
30°
120°
90°
–20 dB
–20 dB
–15 dB
–15 dB
–10 dB
–10 dB
–5 dB
–5 dB
90°
60°
60°
30°
30°
0
0
250 Hz
250 Hz
500 Hz
500 Hz
1000 Hz
1000 Hz
180°
180°
150°
150°
150°
150°
120°
120°
120°
90°
90°
60°
60°
30°
30°
120°
90°
–20 dB
–20 dB
–15 dB
–15 dB
–10 dB
–10 dB
–5 dB
–5 dB
90°
60°
60°
30°
30°
0
0
2500 Hz
2500 Hz
6400 Hz
6400 Hz
10000 Hz
10000 Hz
FIGURE 5. TYPICAL SUPERCARDIOID POLAR PATTERN
6
DIMENSIONS
KSM9
1.918 in.
49 mm
7.5 in.
191 mm
FIGURE 6
CERTIFICATION
Eligible to bear CE Marking; Conforms to European EMC directive 89/336/
EEC. Meets applicable tests and performance criteria found in European Professional Audio Products EMC Standard EN 55103 (1996); Part 1 (emissions)
and part 2 (immunity). The KSM9 is intended for use in environments E1 (residential) and E2 (Light Industrial) as defined in European standard EN 55103.
EMC conformance is based on the use of shielded interconnecting cable.
For additional microphone service or parts information, please contact the
Shure Service Department at 1-800-516-2525. Outside the United States,
please contact your Authorized Shure Service Center.
7
SHURE INCORPORATED
MICROPHONE ÉLECTROSTATIQUE À MAIN KSM9
™
Merci d'avoir choisi le KSM9
Plus de 80 ans d'expérience de la prise de son ont permis d'obtenir le
KSM9, le nec plus ultra des microphones du marché.
Si ce guide ne fournit pas de réponses satisfaisantes à vos questions, appeler le service
clientèle Shure au 847-600-8440, aux États-Unis, du lundi au vendredi, de 8 h à 16 h 30
(heure du Centre). En Europe, appeler le 49-7131-72140. Notre adresse Web est la
suivante : www.shure.com.
1
KSM9
KSM9
DESCRIPTION GÉNÉRALE
Le Shure KSM9 est un microphone électrostatique à main possédant deux
directivités (cardioïde et supercardioïde). Conçu expressément pour la voix en
concert, le KSM9 efface la limite entre le studio et la scène et offre le fin du fin
des performances sur les systèmes de sonorisation haut de gamme modernes
utilisés en tournée. Le large diaphragme double assure une réponse polaire
constante sur toute la plage de fréquences, ce qui permet un gain plus élevé
avant Larsen et réduit au minimum l'effet de proximité, pour une reproduction
claire de la voix.
CARACTÉRISTIQUES
• Double diaphragme de 3/4" en Mylar
®
, de faible masse, à couche d'or, pour
une réponse en fréquence inégalée.
• Double directivité (cardioïde et supercardioïde) pour une flexibilité maximale
quelle que soit l'application.
• Préamplificateur à composants discrets, sans transformateur, de classe A,
permettant une réponse transitoire transparente et extrêmement rapide,
sans distorsion de recoupement, et des distorsions harmoniques et
d'intermodulation minimales.
• Système perfectionné de suspension élastique isolant la capsule des bruits
provenant du pied et de la manipulation.
• Composants électroniques haut de gamme, Connecteurs internes et
externes plaqués or.
• Grille à trois étages réduisant les plosives et autres bruits de respiration.
2
CARACTÉRISTIQUES DES PERFORMANCES
• Réponse régulière et prononcée en hautes fréquences
• Sons clairs et précis dans la partie supérieure de la plage des fréquences
moyennes, sans dureté
• Effet de proximité réduit
• Réponse centrée en basses fréquences
VARIANTES
Modèles câblésDescription
KSM9/SL
KSM9/CG
Microphone à main pour la voix à double
directivité (cardioïde/supercardioïde),
couleur champagne
Microphone à main pour la voix à double di-
rectivité (cardioïde/supercardioïde), couleur
gris anthracite
APPLICATION ET PLACEMENT
Le KSM9 offre un son de qualité supérieure dans toute application exigeant
une qualité acoustique irréprochable. Le KSM9 est le microphone idéal pour
les musiciens en tournée, quel que soit le lieu de spectacle.
La réponse en fréquence des deux directivités du KSM9 produit un son
pratiquement identique, ce qui permet de choisir la configuration la plus
appropriée pour chaque application. La directivité cardioïde produit une
excellente isolation acoustique et un gain élevé avant Larsen, avec une
coloration sonore hors axe minimum. La directivité supercardioïde, plus
étroite, offre une isolation acoustique maximale et est idéale pour les
applications où existent des niveaux élevés de bruit ambiant, ou si plusieurs
instruments ou chanteurs sont proches les uns des autres.
Règles générales d'utilisation du microphone
1. Couper tous les canaux de microphone avant de brancher ou de
débrancher les câbles XLR, de commuter la courbe de directivité et
d'appliquer des atténuateurs, des filtres passe-haut ou l'alimentation
fantôme.
2. Diriger le microphone vers la source sonore désirée et à l'opposé des
sources sonores indésirables.
3. Placer le microphone le plus près possible de la source sonore.
4. La distance entre les microphones doit être d'au moins trois fois celle de
chaque source au microphone qui lui est affecté.
5. Placer les microphones le plus loin possible des surfaces réfléchissantes.
6. Utiliser un minimum de microphones dans la mesure du possible.
7. Si le microphone est utilisé à l’extérieur, le munir d’une bonnette anti-vent
si nécessaire.
8. Ne couvrir aucune partie de la grille avec la main.
3
UTILISATION DU KSM9
Effet de proximité
En général, les microphones unidirectionnels accentuent progressivement
les fréquences graves jusqu'à 10 à 15 dB (à 100 Hz) lorsque le microphone
se trouve à 6 mm de la source sonore. Ce phénomène, appelé effet deproximité, produit un son plus chaud et plus puissant. Malheureusement, il
faut généralement que le chanteur se maintienne à une distance constante
du microphone pour éviter les variations de la réponse en basse fréquence.
Toutefois, la conception à double diaphragme du KSM9 permet aux chanteurs
d'obtenir une réponse en basse fréquence plus stable même si la distance
avec le micro varie durant les spectacles. Enfin, la coupure progressive des
basses fréquences du KSM9 réduit la distorsion ou le son empaté découlant
souvent d'une très grande proximité.
Bruit causé par le vent
Le KSM9 est doté d'un filtre anti-pop et anti-vent intégré qui offre une
excellente protection contre les bruits de vent et de respiration. Une bonnette
anti-vent en mousse proposée en option peut être utilisée lors de vents très
forts ou en présence, à proximité, d'un chanteur "à problèmes".
COMMUTATEUR À DEUX POSITIONS
FIGURE 1
Cardioïde. Est le plus sensible aux sons émis directement devant le
microphone et est le moins sensible aux sons émis derrière. La configuration
cardioïde est la plus fréquemment utilisée pour les applications de
sonorisation en direct. L'angle de captation légèrement plus large est moins
sélectif pour les sons hors axe. Voir figure 3.
Supercardioïde. La configuration plus étroite assure un rejet supérieur
des sons hors axe et un gain maximum avant Larsen. La configuration
supercardioïde est idéale pour une utilisation dans des environnements
bruyants ou dans le cas où les sources sonores sont très proches les unes des
autres. Voir figure 5.
4
Alimentation fantôme
Le KSM9 exige une alimentation fantôme et donne des résultats optimum
avec une alimentation de 48 V c.c. (IEC-268-15/DIN 45 596). Cependant,
l'utilisation du micro est possible avec une alimentation minimale de 11 V c.c.,
au prix d'une légère réduction de la plage dynamique et de la sensibilité.
Impédance
Une impédance de charge minimum de 800 ohms doit être utilisée pour une
gestion maximum des signaux et une distorsion minimum. L'impédance peut
être d'un minimum de 150 ohms, mais cela entraînera une réduction du niveau
de sortie et du seuil d'écrêtage en sortie.
5
CARACTÉRISTIQUES TECHNIQUES
Type de capsuleÉlectrostatique (capsule électret)
Réponse en fréquence50 à 20 000 Hz
Impédance de sortie150 Ω (réelle)
Alimentation fantôme
48 V c.c. ± 4 V c.c. (IEC-268-15/DIN 45 596), broches
Consommation de courant5,2 mA typique à 48 V c.c.
Rejet en mode commun>60 dB, 50 Hz à 20 kHz
PolaritéUne pression positive sur le diaphragme avant produit
Courbes de directivité
directionnelles
une tension positive sur la broche de sortie 2 par
Cardioïde
(Voir figure 3)
Sensibilité
(typique; à 1000 Hz;
1 Pa = 94 dB SPL)
Bruit propre
(typique, SPL équivalent ;
pondéré en A, IEC 651)
SPL maximum à 1000 Hz
2500 Ω de charge
1000 Ω de charge
Niveau d'écrêtage de
sortie*
2500 Ω de charge
1000 Ω de charge
Plage dynamique
2500 Ω de charge
1000 Ω de charge
Rapport signal/bruit**72 dB
Dimensions et poids
*100 Hz à 20 kHz ; DHT < 1 %.
**Le rapport signal/bruit est la différence entre le SPL de 94 dB et le SPL équivalent du bruit propre pondéré en A.
Diamètre hors tout 49 mm (1 15/16 po), longueur de 191