Shure CVG Series, CVGD/12, CVGD/18 Quick Start Manual

General Description

22 mm
(7/8 in.)
The Shure Centraverse CVG is a professional gooseneck electret condenser microphone for use in general installed sound reinforcement applications. With dual gooseneck sections for full articulation, the CVG12/18 provides scalable, best-in-class performance in a wide variety of locations, including podiums and desktops.

Features

Cardioid polar pattern with tailored response for speech
Three model variations with inline preamps: standard, mute switch, and light ring indicator
Available in 12” (30.4 cm) and 18” (45.7 cm) gooseneck lengths
Commshield®technology guards against unwanted RF interference from portable wireless devices (smartphones, etc.)
Included flange mount and snap-fit windscreen
CVG
Gooseneck Condenser Microphone

Model Variations

Gooseneck Length
12: 12" gooseneck 18: 18" gooseneck
Mute Button and LED Indicator*
S: Includes mute button and bi-color LED on microphone body RS: Includes mute button and On/Off colored indicator ring
*The Standard model does not feature a mute switch or LED
Color
B: Black
Polar Pattern
C: Cardioid Note: Model availability depends on region. See your local Shure dealer or
distributor for details.

Installation

1. Drill a 22 mm (7/8 in.) hole in the mounting surface for the flange and three additional holes for the screws.
2. Screw the flange into place, and then set the microphone into the center hole.
3. Connect the microphone to a mixer or P.A. system using an XLR cable. Note: This microphone requires +48V phantom power to operate.

Mute Button Operation

Press the button on the microphone body to turn the mute on/off. The standard model does not feature a mute button.
1. CVG12S: Mute is indicated by an LED on the microphone body:
Green = Microphone is on
Red = Microphone is muted
2. CVG12RS: Mute is indicated by a light ring on the microphone head:
Red = Microphone is on
Off = Microphone is muted
1/4©2017 Shure Incorporated

Guidelines For Use

15 – 30 cm
(6 – 12 in.)
1. Maintain a distance of approximately 15 - 30 cm (6 - 12 in.) between the sound source and the microphone.
2. Always use the supplied windscreen to control plosives and wind noise.
Shure IncorporatedCVG Gooseneck Condenser Microphone

Specifications

Cartridge Type
Electret Condenser
Polar Pattern
Cardioid
Frequency Response
70 Hz to 16,000 Hz
Output Impedance
180 Ω
Sensitivity
open circuit voltage,at 1kHz,typical
-33 dBV/Pa[1](22 mV)
Maximum SPL[2]
1 kHz at 1% THD
120 dBSPL
Signal-to-Noise Ratio[3]
Ref. 94 dB SPLat 1kHz
67 dB
2017/10/052/4