ShowTec Performer Profile 600 LED MKIII User manual

Page 1
Performer Profile 600 LED MKIII V1
Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands
MANUAL
ENGLISH
Page 2
1
Ordercode: 33065
Performer Profile 600 LED MKIII
Table of contents
Warning ............................................................................................................................................................................... 3
Safety Instructions ......................................................................................................................................................... 3
Operating Determinations .......................................................................................................................................... 5
Rigging ............................................................................................................................................................................ 5
Connection with the mains......................................................................................................................................... 6
Return Procedure .......................................................................................................................................................... 7
Claims .............................................................................................................................................................................. 7
Description of the device ................................................................................................................................................. 8
Features .......................................................................................................................................................................... 8
Optional accessories.................................................................................................................................................... 8
Overview ........................................................................................................................................................................ 9
Backside .......................................................................................................................................................................10
Installation .........................................................................................................................................................................11
Set Up and Operation .....................................................................................................................................................11
Lens Locations .............................................................................................................................................................11
Focusing the beam ....................................................................................................................................................11
Color frame retaining clip .........................................................................................................................................12
Color Notes ..................................................................................................................................................................12
Shaping the beam......................................................................................................................................................12
Shutters ..........................................................................................................................................................................13
Drop-in Iris-Slot ..............................................................................................................................................................13
Rotating the barrel assembly....................................................................................................................................14
Installation with clamp ...............................................................................................................................................14
Setting the angle ........................................................................................................................................................15
Control Modes .............................................................................................................................................................16
One Performer (Manual control) ..........................................................................................................................16
Multiple Performers (Master/Slave control) ........................................................................................................16
Multiple Performers (DMX Control) .......................................................................................................................17
Fixture Linking ...............................................................................................................................................................18
Data Cabling ...............................................................................................................................................................18
Control Panel ...............................................................................................................................................................19
Control Mode ..............................................................................................................................................................19
DMX Addressing ..........................................................................................................................................................19
Menu Overview ...........................................................................................................................................................20
Main Menu Options ....................................................................................................................................................21
1. Dimmer ..................................................................................................................................................................21
2. Run Mode ..............................................................................................................................................................21
3. Address ..................................................................................................................................................................22
4. Setting ....................................................................................................................................................................22
4.1 Safety key ............................................................................................................................................................22
4.2 Dimmer speed ....................................................................................................................................................23
4.3 Dimming curve settings ....................................................................................................................................23
4.4 Performance settings ........................................................................................................................................23
4.5 Settings menu safety lock ................................................................................................................................23
4.6 DMX channel modes ........................................................................................................................................23
4.7 Save DMX/Blackout ..........................................................................................................................................24
4.8 Reset settings ......................................................................................................................................................24
4.9 Mode Setting ......................................................................................................................................................24
4.10 PWM RATE .........................................................................................................................................................24
DMX Channels .............................................................................................................................................................25
1 Channel (UNO) .....................................................................................................................................................25
2 Channels (DOS) ....................................................................................................................................................25
3 Channels (STD.P) ...................................................................................................................................................25
Page 3
2
Ordercode: 33065
Performer Profile 600 LED MKIII
Cleaning ............................................................................................................................................................................26
Cleaning 19°, 26°, 36°, and 50° glass lenses ..........................................................................................................26
Cleaning the reflector................................................................................................................................................26
Maintenance ....................................................................................................................................................................27
Replacing the Fuse .....................................................................................................................................................27
Troubleshooting ...............................................................................................................................................................27
No Light .........................................................................................................................................................................27
No Response to DMX..................................................................................................................................................28
Product Specifications ....................................................................................................................................................29
Dimensions ........................................................................................................................................................................30
Page 4
3
Ordercode: 33065
Performer Profile 600 LED MKIII
Warning
Unpacking Instructions
Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure that all parts are present, and have been received in good condition. Notify the dealer immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.
Your shipment includes:
Showtec Performer Profile 600 LED MKIII
PowerCON to Schuko power cable 1,5 m
1 safety cable
User manual
LED Expected Lifespan
LEDs gradually decline in brightness over time. HEAT is the dominant factor that leads to the acceleration of this decline. Packaged in clusters, LEDs exhibit higher operating temperatures than in ideal or singular optimum conditions. For this reason, when all color LEDs are used at their fullest intensity, life of the LEDs is significantly reduced. If improving the lifespan is of higher priority, place care in providing for lower operational temperatures. This may include climatic-environmental and the reduction of overall projection intensity.
Safety Instructions
Every person involved with the installation, operation and maintenance of this device has to:
be qualified
follow the instructions of this manual
Before the initial start-up, please make sure that there is no damage caused by transportation.
Page 5
4
Ordercode: 33065
Performer Profile 600 LED MKIII
Should there be any, consult your dealer and do not use the device.
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes contained in this manual.
Please consider that damages caused by manual modifications to the device are not subject to warranty.
This device contains no user-serviceable parts. Refer servicing to qualified technicians only.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device.
Never let the power cord come into contact with other cables! Handle the power cord and all
connections with the mains with particular caution!
Never modify, bend, mechanically strain, put pressure on, pull or heat up the power cord.
Never strain the cable insert or the female part in the device. There must always be sufficient cable
going to the device. Otherwise, the cable will be damaged, which can cause serious damage.
Never remove warning or informative labels from the unit.
Never use anything to cover the ground contact.
Never lift the fixture holding it by the projector-head, as the mechanics may be damaged. Always
hold the fixture by the transport handles.
Never place any material over the lens.
Never look directly into the light source.
Never leave any cables lying around.
Do not insert objects into air vents.
Do not connect this device to a dimmerpack.
Do not switch the device on and off in short intervals, as this will reduce the device’s life.
Do not touch the device’s housing bare-handed during its operation (housing becomes very hot).
Allow the fixture to cool for at least 5 minutes before handling.
Do not shake the device. Avoid brute force when installing or operating the device.
Only use the device indoors, avoid contact with water or other liquids.
Only operate the fixture after having checked if the housing is firmly closed and all screws are tightly
fastened.
Only operate the device after having familiarized with its functions.
Avoid flames and do not put close to flammable liquids or gases.
Always keep the case closed while operating.
Always allow a free air space of at least 50 cm around the unit for ventilation.
Always disconnect power from the mains, when device is not used or before cleaning! Only handle
the power cord holding it by the plug. Never pull out the plug by tugging the power cord.
Make sure that the device is not exposed to extreme heat, moisture or dust.
Make sure that the available voltage is not higher than stated on the rear panel.
Make sure that the power cord is never crimped or damaged. Check the device and the power
cord from time to time.
If the lens is obviously damaged, it has to be replaced to prevent its functions from being impaired,
due to cracks or deep scratches.
If the external cable is damaged, it has to be replaced by a qualified technician.
If device was dropped or struck, disconnect mains power supply immediately. Have a qualified
engineer inspect for safety before operating.
If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not
switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely
(preferably in the original packing material), and return it to your Showtec dealer for service.
For adult use only. The device must be installed beyond the reach of children. Never leave the unit
running unattended.
Never attempt to bypass the thermostatic switch or fuses.
For replacement use fuses of same type and rating only.
Page 6
5
Ordercode: 33065
Performer Profile 600 LED MKIII
The user is responsible for correct positioning and operating of the Performer. The manufacturer will
not accept liability for damages caused by the misuse or incorrect installation of this device.
This device falls under protection class I. Therefore it is essential to connect the yellow/green
conductor to earth.
Repairs, servicing and electric connection must be carried out by a qualified technician.
WARRANTY: Till one year after date of purchase.
Operating Determinations
This device is not designed for permanent operation. Consistent operation breaks will ensure that the
device will serve you for a long time without defects.
The minimum distance between light output and the illuminated surface must be bigger than 1
meter.
In order to eliminate wear and improve the device’s lifespan, during periods of non-use, completely
disconnect from power source via breaker or by unplugging.
The maximum ambient temperature t
a
= 40°C must never be exceeded.
The relative humidity must not exceed 50 % with an ambient temperature of 40° C.
If this device is operated in any other way than the one described in this manual, the product may
suffer damages and the warranty becomes void.
Any other operation may lead to dangers like short-circuit, burns, electric shock, crash, etc.
You endanger your own safety and the safety of others!
Rigging
Please follow the European and national guidelines concerning rigging, trussing and all other safety issues.
Do not attempt the installation yourself ! Always let the installation be carried out by an authorized dealer !
Procedure:
If the device is lowered from the ceiling or high joists, professional trussing systems have to be used.
Use a clamp to mount the device, with the mounting bracket, to the trussing system.
The device must never be fixed swinging freely in the room.
The installation must always be secured with a safety attachment, e.g. an appropriate safety net or
safety cable.
When rigging, derigging or servicing the device, always make sure, that the area below the
installation site is secured and that there are not any unauthorized people around.
Improper installation can cause serious injuries and/or damage of property!
Page 7
6
Ordercode: 33065
Performer Profile 600 LED MKIII
Connection with the mains
Connect the device to the mains with the power-plug. Always check if the right color cable is connected to the right place.
International
EU Cable
UK Cable
US Cable
Pin
L
BROWN
RED
YELLOW/COPPER
PHASE
N
BLUE
BLACK
SILVER
NEUTRAL
YELLOW/GREEN
GREEN
GREEN
PROTECTIVE
GROUND
Make sure that the device is always properly connected to the earth!
Improper installation can cause serious injuries and/or damage of property!
Page 8
7
Ordercode: 33065
Performer Profile 600 LED MKIII
Return Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. Call Highlite 0031-455667723 or mail aftersales@highlite.nl and request an RMA prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use.
Note: If you are given an RMA number, please include the following information on a piece of paper inside the box:
01) Your name
02) Your address
03) Your phone number
04) A brief description of the symptoms
Claims
The client has the obligation to check the delivered goods immediately upon delivery for any short­comings and/or visible defects, or perform this check after our announcement that the goods are at their disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be reported to the carrier upon receipt of merchandise. It is the customer's responsibility to report and submit claims with the shipper in the event that a fixture is damaged due to shipping. Transportation damage has to be reported to us within one day after receipt of the delivery. Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless agreed otherwise in writing. Complaints against us must be prepared in writing or sent by fax within 10 working days after receipt of the invoice. After this period complaints will not be handled anymore. Complaints will only then be considered if the client has so far complied with all parts of the agreement, regardless of the agreement from which the obligation is resulting.
Page 9
8
Ordercode: 33065
Performer Profile 600 LED MKIII
Description of the device
Features
The Showtec Performer Profile 600 LED MKIII is a theater spotlight fixture with high output and great effects.
Extremely quiet
Accessory slot for motorized pattern devices or optional iris
Input Voltage: 100 - 240V AC, 50/60Hz
Power Consumption: 250W
Light Source: 1 x 260W COB LED
Output: 10665 Lumen
Peak Intensity: 182532 cd
Color Rendering: >90Ra
Refresh Rate: 1200Hz
Color Temperature: 3200K
Dimmer: 0-100%
Dim Curve: Dimm4 technology, 4 presets
16-bit virtual dimming engine for smooth fades
Strobe: 0-20Hz
Connections: PowerCON power connectors IN/OUT, 3- & 5-pin XLR signal connectors IN/OUT
Power Linking: 4 units @ 120V; 7 units @ 230V
DMX channels: 1, 2 or 3 channels
Control: DMX, Manual, Master/Slave
Housing: Die-cast aluminum
Cooling: Internal fan + air convection-silent fan
IP Rating: IP20
Fuse: T6,3AL/250V
Dimensions: 485 x 305 x 460 mm (LxWxH)
Weight: 8,2 kg
Optional accessories
33070 - Zoom Lens for Performer Profile, 15º - 30º 33071 - Zoom Lens for Performer Profile, 25º - 50º 33072 - 19º lens for Performer Profile 33073 - 36º lens for Performer Profile 33074 - 50º lens for Performer Profile 33075 - 26º lens for Performer Profile 33076 - Iris for Performer Serie 33077 - Soft edge holder 33078 - Metal gobo holder 33079 - Glass gobo holder
Page 10
9
Ordercode: 33065
Performer Profile 600 LED MKIII
Overview
Fig. 01
01) Lens tube (not included)
02) Barrel
03) Shutter
04) Body
05) Adjustment handle
06) Mounting bracket
07) Safety Eye
Page 11
10
Ordercode: 33065
Performer Profile 600 LED MKIII
Backside
Fig. 02
08) LCD display + control buttons
09) Fuse T6,3AL/250V
10) PowerCON power connector 100-240V IN (Blue)
11) PowerCON power connector 100-240V OUT (Grey)
12) 5-pin DMX signal connector IN
13) 5-pin DMX signal connector OUT
14) 3-pin DMX signal connector OUT
15) 3-pin DMX signal connector IN
Page 12
11
Ordercode: 33065
Performer Profile 600 LED MKIII
Installation
Remove all packing materials from the Performer Profile 600 LED MKIII. Check if all foam and plastic padding is removed. Connect all cables.
Do not supply power before the whole system is set up and connected properly. Always disconnect from electric mains power supply before cleaning or servicing. Damages caused by non-observance are not subject to warranty.
Set Up and Operation
Follow the directions below, as they pertain to your preferred operation mode. Before plugging the unit in, always make sure that the power supply matches the product specification voltage. Do not attempt to operate a 120V specification product on 230V power, or vice versa. Connect the device to the main power supply. The device can be sound-controlled as it is equipped with a built-in microphone.
Lens Locations
The different lenses used in the Performer are not interchangeable. When installing a new lens, refer to the illustration below for proper placement.
Fig. 03
Focusing the beam
01) Loosen the beam focus controls located under the barrel (Fig. 04).
02) Slide the lens tube forwards or backwards to achieve the desired beam edge.
03) Once the fixture is focused, tighten the beam focus controls.
Fig. 04
Page 13
12
Ordercode: 33065
Performer Profile 600 LED MKIII
Color frame retaining clip
The color frame holder is equipped with a spring-loaded retaining clip. This prevents color frames and accessories from falling out (Fig. 05).
Make sure that all color frame accessories are locked in position with the retaining clip
before hanging the Performer Profile 600 LED MKII.
01) Release the retaining clip by pushing it sideways while gently pulling backwards.
02) Insert the color frame(s).
03) Lock the retaining clip by pushing sideways while gently pushing forward.
Fig. 05
Color Notes
The performance of saturated colors is not guaranteed with low temperature ranges. For best results, always use a high quality and temperature color medium. This product color extender may help increase your gel life. Contact your dealer for ordering information.
Soft Focus,
Tube Retracted
Sharp Focus
Soft Focus
Tube Extended
19º
W
B
B
26º
W
B
B
36º
B
B
W
50º
W
B
B
W:
Worse gel life
B:
Better gel life
Shaping the beam
You may shape the beam with the shutters, a pattern, an optional drop-in iris or by rotating the barrel.
Page 14
13
Ordercode: 33065
Performer Profile 600 LED MKIII
Shutters
The shutters are located inside the barrel. Move them back and forth to modify the shape of the beam.
Fig. 06
Drop-in Iris-Slot
The Drop-in Iris slot is located on the top of the barrel. It accommodates either a drop-in iris or a motorized pattern device. When the slot is not in use, a small sheet metal cover secured with 2 screws prevents light leakage (Fig. 07).
01) Use a screwdriver to loosen the screws on the drop-in iris slot cover. Do not remove the screws.
02) Slide the cover completely forward to expose the slot.
03) Insert the iris or motorized pattern device. For an iris, install the flat side towards the shutters and make
sure that the iris handle extends from the slot.
04) Slide the slot cover back towards the shutters, until it meets the iris handle. Leave enough space to
move the iris handle.
05) Secure the drop-in iris slot cover by tightening the screws.
Fig. 07
Page 15
14
Ordercode: 33065
Performer Profile 600 LED MKIII
Rotating the barrel assembly
01) Loosen the barrel rotation control. It can be found directly behind the shutters on the underside of
the reflector housing (Fig 08). Do not remove the barrel rotation control.
02) Rotate the barrel to the desired position.
03) Once the barrel is positioned, tighten the barrel’s rotation control to lock it into position.
Fig. 08
Installation with clamp
You can choose an appropriate clamp from your dealer to fix the fixture to a trussing system and it allows you to adjust the position of the fixture once it is mounted. (Fig. 09).
01) Tightly fasten the clamp to the mounting bracket with the provided pipe bolt and lock washer.
02) Place the clamp on the truss, then tighten the bolt to secure it.
03) Loosen the clamp pan screw and rotate the mounting bracket to the desired position.
04) Tighten the clamp pan screw to lock the fixture into position.
Fig. 09
Page 16
15
Ordercode: 33065
Performer Profile 600 LED MKIII
Setting the angle
01) Loosen the adjustment screws. Do not remove the adjustment screws.
02) Tilt the fixture to the desired position (Fig. 10).
03) Tighten the adjustment screws to secure the fixture in position.
Fig. 10
Page 17
16
Ordercode: 33065
Performer Profile 600 LED MKIII
Control Modes
There are 3 modes:
Manual control (Dimmer)
Master/Slave
DMX-512 (1CH, 2CH, 3 CH)
One Performer (Manual control)
01) Fasten the effect light to a firm trussing. Leave at least 0,5 meter on all sides for air circulation.
02) Always use a safety cable (ordercode 70140 / 70141).
03) Plug the end of the electric mains power cord into a proper electric power supply socket.
04) When the Performer is not connected with a DMX cable, it functions as a stand-alone device.
Please see page 21 for more information about the Manual control (Dimmer).
Multiple Performers (Master/Slave control)
01) Fasten the effect light onto firm trussing. Leave at least 0,5 meter on all sides for air circulation.
02) Always use a safety cable (ordercode 70140 / 70141).
03) Use a 3-pin XLR cable to connect the Performer.
The pins:
01) Earth
02) Signal -
03) Signal +
04) Link the units as shown in fig. 11. Connect the first unit's DMX "out" socket with the second unit's "in"
socket, using a DMX-signal cable. Repeat this process to link the second and third units. You can use the same functions on the master device as described on page 21 (Manual control). This means that you can set your desired operation mode on the master device and all slave devices will react the same as the master device.
Multiple Performers (Master/Slave control)
Fig. 11
Page 18
17
Ordercode: 33065
Performer Profile 600 LED MKIII
Multiple Performers (DMX Control)
01) Fasten the effect light to a firm trussing. Leave at least 0,5 meter on all sides for air circulation.
02) Always use a safety cable (ordercode 70140 / 70141).
03) Use a 3-pin XLR cable to connect the Performers and other devices.
04) Link the units as shown in fig. 12. Connect the first unit's DMX "out" socket with the second unit's "in"
socket, using a DMX-signal cable. Repeat this process to link the second and third units.
05) Supply electric power: Plug electric mains power cords into each unit's PowerCON socket, then plug
the other end of the mains power cord into proper electric power supply sockets, starting with the first unit. Do not supply power before the whole system is set up and connected properly.
Multiple Performers DMX Set Up
Fig. 12
Note : Link all cables before connecting electric power
Page 19
18
Ordercode: 33065
Performer Profile 600 LED MKIII
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run synchronized shows of two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support.
Important:
Fixtures on a serial data link must be daisy-chained in a single line. To comply with the EIA-485 standard, no more than 30 devices should be connected on one data link. Connecting more than 30 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal.
Maximum recommended DMX data link distance: 100 meters Maximum recommended number of fixtures on a DMX data link: 30 fixtures
Maximum recommended number of fixtures on a Powercon link: 4 units @120V
Maximum recommended number of fixtures on a Powercon link: 7 units @230V
Data Cabling
To link fixtures together, you must obtain data cables. You can purchase DAP Audio certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable, please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.
DAP Audio DMX Data Cables
DAP Audio Basic microphone cable for allround use. bal. XLR/M 3-pin > XLR/F 3-pin.
Ordercode FL01150 (1,5 m), FL013 (3 m), FL016 (6 m), FL0110 (10 m), FL0115 (15 m), FL0120 (20 m).
DAP Audio X-type data cable XLR/M 3-pin > XLR/F 3-pin. Ordercode FLX0175 (0,75 m),
FLX01150 (1,5 m), FLX013 (3 m), FLX016 (6 m), FLX0110 (10 m).
DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by
Neutrik®. Ordercode FL71150 (1,5 m), FL713 (3 m), FL716 (6 m), FL7110 (10 m).
DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by
Neutrik®. Ordercode FL7275 (0,75 m), FL72150 (1,5 m), FL723 (3 m), FL726 (6 m), FL7210 (10 m).
DAP Audio 110 Ohm cable with digital signal transmission. Ordercode FL0975 (0,75 m),
FL09150 (1,5 m), FL093 (3 m), FL096 (6 m), FL0910 (10 m), FL0915 (15 m), FL0920 (20 m).
DAP Audio DMX adapter: 5-pin > 3-pin. Ordercode FLA29.
DAP Audio DMX adapter: 3-pin > 5-pin. Ordercode FLA30.
DAP Audio DMX Terminator 3-pin. Ordercode FLA42.
DAP Audio DMX Terminator 5-pin. Ordercode FLA43.
The Performer Profile 600 can be operated with a controller in control mode or without the controller in stand-alone mode.
Page 20
19
Ordercode: 33065
Performer Profile 600 LED MKIII
Control Panel
A) LCD Display
B) MENU button
C) ENTER button
D) UP button
E) DOWN button
Fig. 13
Control Mode
The fixtures are individually addressed on a data-link and connected to the controller. The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it, the controller will display the saved DMX address, next time.)
DMX Addressing
The control panel on the front side of the base allows you to assign DMX fixture addresses, which is the first channel with which the Performer will respond to the controller. Please note, when you use the controller, the unit has 3 channels. When using multiple Performers, make sure you set the DMX addresses right. Therefore, the DMX address of the first Performer should be 1(001); the DMX address of the second Performer should be 1+3=4 (004); the DMX address of the third Performer should be 4+3=7 (007), etc. Please, be sure that you do not have any overlapping channels in order to control each Performer correctly. If two or more Performers are addressed similarly, they will work similarly.
Controlling:
After having addressed all Performer fixtures, you may now start operating these via your lighting controller. Note: After switching on, the Performer will automatically detect whether DMX 512 data is received or not. If there is no data received at the DMX-input, the problem may be:
The XLR cable from the controller is not connected with the input of the Performer.
The controller is switched off or defective, the cable or connector is detective, or the signal wires are
swapped in the input connector.
Note: It is necessary to insert an XLR termination plug (with 120 Ohm) in the last fixture in order to ensure proper transmission on the DMX data link.
Display Off after 30 seconds
When no button is pressed for 30 seconds, the display will turn off. To light up the display, you have to press the MENU, UP, DOWN or ENTER button. Once you have pressed the button, the display will light up.
Page 21
20
Ordercode: 33065
Performer Profile 600 LED MKIII
Menu Overview
Page 22
21
Ordercode: 33065
Performer Profile 600 LED MKIII
Main Menu Options
01) On start-up, the device will display information about the device’s actual temperature, the current
software version, run mode, DMX personality and DMX address:
02) Press the ENTER button to open the main menu.
03) Press the UP/DOWN buttons to toggle through the main menu options.
04) Press the ENTER button to open the desired submenu.
1. Dimmer
In this menu you can manually adjust the dimmer intensity.
01) While in the main menu, press the UP and DOWN buttons until the display shows DIMMING.
02) Press the ENTER button to open the menu, the display will show:
03) Press the UP and DOWN button to adjust the dimmer intensity. The adjustment range is
between 000-255.
2. Run Mode
In this menu you can set the device as a DMX fixture or slave fixture.
01) While in the main menu, press the UP and DOWN buttons until the display shows RUN MODE.
02) Press the ENTER button to open the menu, the display will show:
03) Press the UP and DOWN buttons to toggle between the 2 options.
04) If the display shows DMX, the Performer will become a master device and will utilize the DMX
protocol to determine its performance.
05) If the display shows SLAVE, the Performer will become a slave device and will react the same as the
master device.
Page 23
22
Ordercode: 33065
Performer Profile 600 LED MKIII
3. Address
In this menu you can set the desired DMX starting address.
01) While in the main menu, press the UP and DOWN buttons until the display shows ADDRESS.
02) Press the ENTER button to open the menu, the display will show:
03) Press the UP/DOWN buttons to set the desired DMX starting address. The adjustment range is
between 001-512.
04) Press the ENTER button to save settings.
4. Setting
In this menu you can adjust the device’s special settings.
01) While in the main menu, press the UP and DOWN buttons until the display shows SETTING.
02) Press the ENTER button to open the menu.
03) The display will show: .
04) Insert the password: UP>DOWN>UP>DOWN and press the ENTER button to confirm.
05) Press the UP and DOWN buttons to toggle between the following adjustable options:
KEY
Safety key
DIMMER
Dimmer speed
CURVE
Dimming curve settings
PERFORM
Performance settings
SLOCK
Settings menu safety lock
PERSONALITY
DMX channel modes
DMX ERROR
Save DMX/Blackout
RESET
Reset settings
MODE SETTING
DMX data transfer
PWM RATE
Refresh Rate
4.1 Safety key
01) When the display shows KEY, press the ENTER button to open the menu.
02) Press the UP and DOWN buttons to toggle between OFF and ON to deactivate/activate the safety
lock.
03) When the option is active, you will need to insert the safety key combination every time the display
turns off.
04) When the option is inactive, the Settings menu will not get locked, providing that the device remains
in it.
05) If the display shows SETTING and turns off after 30 seconds – you will need to re-insert the safety key,
anyway.
Page 24
23
Ordercode: 33065
Performer Profile 600 LED MKIII
4.2 Dimmer speed
01) When the display shows DIMMER, press the ENTER button to open the menu.
02) Press the UP and DOWN buttons to toggle between the 5 options:
OFF
Dimmer Speed OFF
DIM1- DIM 4
Dimmer speed, from fast to slow
4.3 Dimming curve settings
01) When the display shows CURVE, press the ENTER button to open the menu.
02) Press the UP and DOWN buttons to choose the desired dimming curve out of the 4 available options:
4.4 Performance settings
01) When the display shows PERFORM, press the ENTER button to open the menu.
02) Press the UP and DOWN buttons to toggle between the 3 modes:
LIVE
Default mode. It provides a compromise between output quality and noise level of the fan.
STUDIO
Noise level-oriented mode. The performer emits little noise and operates at moderate power level.
POWER
Output-oriented mode. The device does not offer any consideration for the noise level of the fan and operates at full power.
4.5 Settings menu safety lock
01) When the display shows SLOCK, press the ENTER button to open the menu.
02) Press the UP and DOWN buttons to toggle between OFF and ON to deactivate/activate the menu
lock.
03) When the option is active, you will always need to insert the safety key/pass code in attempt to enter
the Settings menu.
4.6 DMX channel modes
With this menu you can set the desired DMX channel mode/personality.
01) When the display shows PERSONALITY, press the ENTER button to open the menu.
02) Press the UP and DOWN buttons to toggle between the 3 channel modes:
UNO
1-channel mode
DOS
2-channel mode
STD.P
3-channel mode
03) Press the ENTER button to save settings.
Page 25
24
Ordercode: 33065
Performer Profile 600 LED MKIII
4.7 Save DMX/Blackout
01) When the display shows DMX ERROR, press the ENTER button to open the menu.
02) Press the UP and DOWN buttons to toggle between the 2 options:
SAVE
DMX data save
BLACK
Blackout
03) If the display shows SAVE, the Performer will fall back on the last working DMX signal, which will ensure
undisrupted performance.
04) If the display shows BLACK, the Performer will blackout, in case of a DMX signal error.
4.8 Reset settings
01) When the display shows RESET, press the ENTER button to enter the menu. The display will show Pass
Code.
02) Insert the safety key combination by pressing the buttons in the following order: UP, DOWN, UP,
DOWN, ENTER.
03) The display will promptly show OK! and the settings will have been reset.
4.9 Mode Setting
01) When the display shows MODE SETTING, press the ENTER button to open the menu.
02) Press the UP and DOWN buttons to toggle between the 2 options:
SELF
DMX data transfer OFF
MAST
DMX data transfer ON
03) If the display shows SELF, the Performer will not send DMX data to the other connected devices.
04) If the display shows MAST, the Performer will send DMX data to the other connected devices.
4.10 PWM RATE
01) When the display shows PWM RATE, press the ENTER button to open the menu.
02) Press the UP and DOWN buttons to toggle between the 5 options:
600Hz 1200Hz 2000Hz 4000Hz 25000Hz
03) Press the ENTER button to save settings.
Note:
When the refresh rate is increased, the gray dimmer rate will be reduced (that means high refresh rate, low gray rate). When the PWM rate is 4000Hz, CURV3 is invalid. (see page 23) When the PWM rate is 25000Hz, CURV1, CURV2 and CURV3 are invalid. So please lower the PWM rate to increase the gray rate.
Page 26
25
Ordercode: 33065
Performer Profile 600 LED MKIII
DMX Channels
1 Channel (UNO)
Channel 1 – Dimmer
0-255
Dimmer intensity, from dark to brightest 0-100%
2 Channels (DOS)
Channel 1 – Dimmer
0-255
Dimmer intensity, from dark to brightest 0-100%
Channel 2 – Fine dimmer
0-255
Fine dimmer adjustment
3 Channels (STD.P)
Channel 1 – Dimmer
0-255
Dimmer intensity, from dark to brightest 0-100%
Channel 2 – Fine dimmer
0-255
Fine dimmer adjustment
Channel 3 – Strobe
0-9
Strobe OFF
10-99
Strobe ON, from slow to fast
100-109
Strobe OFF
110-179
Pulse strobe ON, from slow to fast
180-189
Strobe OFF
190-255
Random strobe, from slow to fast
Page 27
26
Ordercode: 33065
Performer Profile 600 LED MKIII
Cleaning
Please follow the next recommendations when cleaning and inspecting lenses and reflectors: Do not use glass or window type cleaners on lenses (glass or polymer) or reflectors. Do not use abrasive materials such as steel wool. Replace lenses if they contain visible damage (cracks or deep scratches) which that may impair their effectiveness.
Cleaning 19°, 26°, 36°, and 50° glass lenses
01) Remove the beam focus controls at the bottom of the barrel. Remove the lens tube from the barrel.
02) Dampen a clean lint-free cloth with vinegar or household ammonia. You may also use water, but it
will leave spots that can be removed by gently polishing the lens with a clean and dry cloth.
03) Starting from the center, gently wipe the lens.
04) Slide the lens tube back into the barrel with the color frame-retaining clip on top. Replace the beam
focus controls.
Cleaning the reflector
Unplug the fixture before attempting to clean the reflector. To quickly clean the reflector, remove the lens tube and clean the dust from the reflector with a blast of oil­free air. You may also wipe the reflector with a clean lint-free cloth. If either method is not sufficient, follow the instructions below. You will need a screwdriver to complete this procedure.
01) Remove the barrel rotation controls located at the bottom of the barrel. Use a screwdriver to remove
the retainer bolt located on top of the reflector housing.
02) Rotate the barrel by 45° in either direction. Carefully remove the barrel from the reflector housing.
03) Dampen a clean lint-free cloth with alcohol or distilled water (alcohol is recommended).
04) Gently wipe the reflector.
05) Insert the barrel into the reflector housing with the iris/pattern slot on top (line up the triangles on both
parts).
06) While pressing in gently, rotate the barrel by 45° clockwise until it sets into position. Then, rotate the
barrel counterclockwise 45°. The barrel should be firmly attached and the triangles should line up again.
07) Replace the barrel rotation controls and tighten the retainer bolt.
Page 28
27
Ordercode: 33065
Performer Profile 600 LED MKIII
Maintenance
The operator has to make sure that safety-related and machine-technical installations are to be inspected by an expert after every year in the course of an acceptance test. The operator has to make sure that safety-related and machine-technical installations are to be inspected by a skilled person once a year.
The following points have to be considered during the inspection:
01) All screws used for installing the device or parts of the device have to be tightly connected and
must not be corroded.
02) There may not be any deformations on housings, fixations and installation spots.
03) Mechanically moving parts like axles, eyes and others may not show any traces of wearing.
04) The electric power supply cables must not show any damages or material fatigue.
The Performer Profile 600 requires almost no maintenance. However, you should keep the unit clean. Otherwise, the fixture’s light-output will be significantly reduced. Disconnect the mains power supply, and then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass cleaner and a soft cloth. Do not use alcohol or solvents. The front lens will require weekly cleaning, as smoke-fluid tends to build up residues, reducing the light­output very quickly. Please clean internal components once a year with a light brush and vacuum cleaner. Keep connections clean. Disconnect electric power, and then wipe the DMX and audio connections with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying electric power.
Replacing the Fuse
Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the fuse burns out, the product will not function whatsoever. If this happens, follow the directions below:
01) Unplug the unit from electric power source.
02) Insert a flat-head screwdriver into a slot in the fuse cover. Turn the screwdriver to the left, at the same
time gently push a bit (Turn and Push). The fuse will come out.
03) Remove the used fuse. If brown or unclear, it is burned out.
04) Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover. Be sure to
use a fuse of the same type and specification. See the product specification label for details.
Troubleshooting
This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit operates properly, do not carry out following steps.
No Light
If the light effect does not operate properly, refer servicing to a technician. Suspect three potential problem areas as: the power supply, the LED, the fuse.
01) Power supply. Check if the unit is plugged into an appropriate power supply.
02) The LED. Return the Performer to your Showtec dealer.
03) The fuse. Replace the fuse. See page 27 for replacing the fuse.
04) If all of the above appears to be O.K., plug the unit in again.
05) If you are unable to determine the cause of the problem, do not open the Performer, as this may
damage the unit and the warranty will become void.
06) Return the device to your Showtec dealer.
Page 29
28
Ordercode: 33065
Performer Profile 600 LED MKIII
No Response to DMX
Response: Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card malfunction.
01) Check the DMX setting. Make sure that DMX addresses are correct.
02) Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power.
Try your DMX control again.
03) Determine whether the controller or light effect is at fault. Does the controller operate properly with
other DMX products? If not, take the controller in for repair. If so, take the DMX cable and the light effect to a qualified technician.
Problem
Probable cause(s)
Solution
One or more fixtures do not function at all
No power to the fixture
Check if power is switched on and cables are plugged in
Primary fuse blown
Replace fuse
Fixtures reset correctly, but all respond erratically or not at all to the controller
The controller is not connected
Connect controller
3-pin XLR Out of the controller does not match XLR Out of the first fixture on the link (i.e. signal is reversed)
Install a phase reversing cable between the controller and the first fixture on the link
Fixtures reset correctly, but some respond erratically or not at all to the controller
Poor data quality
Check data quality. If much lower than 100 percent, the problem may be a bad data link connection, poor quality or broken cables, missing termination plug, or a defective fixture disturbing the link
Bad data link connection
Inspect connections and cables. Correct poor connections. Repair or replace damaged cables
Data link not terminated with 120 Ohm termination plug
Insert termination plug in output jack of the last fixture on the link
Incorrect addressing of the fixtures
Check address setting
One of the fixtures is defective and disturbs data transmission on the link
Bypass one fixture at a time until normal operation is restored: unplug both connectors and connect them directly together.
Have the defective fixture serviced by a qualified technician
3-pin XLR Out on the fixtures does not match (pins 2 and 3 reversed)
Install a phase-reversing cable between the fixtures or swap pin 2 and 3 in the fixture that behaves erratically
Shutter closes suddenly
The color wheel, gobo wheel or a gobo has lost its index position and the fixture is resetting the effect
Contact a technician for servicing if the problem persists
No light or LED cuts out intermittently
Fixture is too hot
Allow the fixture to cool down
Clean the fan
Make sure air vents in control
panel and the front lens are not blocked
Turn up the air conditioning
LED damaged
Disconnect the fixture and return it to your dealer
The power supply settings do not match local AC voltage and frequency
Disconnect fixture. Check settings and correct if necessary
Page 30
29
Ordercode: 33065
Performer Profile 600 LED MKIII
Product Specifications
Model:
Showtec Performer Profile 600 LED MKIII
Input Voltage:
100 - 240V AC, 50/60Hz
Power consumption:
250W (full output)
DMX linking:
30pcs
Fuse:
T6,3AL/250V
Dimensions:
485 x 305 x 460 mm (LxWxH)
Weight:
8,2 kg
Operating and Programming:
Signal pin OUT:
Pin 1 (earth), pin 2 (-), pin 3 (+)
DMX Mode:
1, 2, 3 Channels
Signal input:
3-pin/5-pin XLR male
Signal output:
3-pin/5-pin XLR female
Electro-mechanical effects:
Light Source:
1 x 260W COB LED
Focus:
Manual
Dimmer:
0-100%
Dim Curve:
Dimm4 technology, 4 presets
Strobe:
0-20Hz
Peak Intensity:
182532cd
Max. Flux:
10665 Lumen
Color Rendering:
>90Ra
Color Temperature:
3200K
Refresh Rate:
1200Hz
Housing:
Die-cast aluminum
DMX-control:
via standard DMX-controller
On Board:
LCD display for easy setup
Control:
DMX, Manual, Master/Slave
Connections:
PowerCON power connectors IN/OUT, 3- & 5-pin XLR signal connectors IN/OUT,
IP Rating:
IP20
Cooling:
Internal fan + air convection-silent fan
Max. ambient temperature ta:
40°C
Max. housing temperature tB:
80°C
Minimum distance:
Minimum distance from flammable surfaces:
0,5 m
Minimum distance to lighted object:
1 m