Shop fox D4532 User Manual

Model D4532
#16600TS
Wide Single Mini
ON/OFF Switch
Instruction Sheet
Phone #: (360) 734-3482 • Online Tech Support: tech-support@shopfox.biz • Web: www.shopfox.biz
To reduce risk of serious burns, electrocu­tion or death when installing this switch:
• Only use this switch to replace an exist­ing component switch that has the same physical configuration and equivalent electrical specifications/ratings.
• Installation must only be performed by an electrician or qualified service personnel, and all applicable electrical codes must be adhered to.
• Turn OFF and completely disconnect all power sources to the component before installing the switch.
Figure 1. D4532 Wide Single Mini ON/OFF
Switch.
Introduction
The Model D4532 features a wide single ON/ OFF toggle switch and fits into a rectangular hole.
3
4" x 7⁄8"
• Only install this switch on the "hot" wires. Do not install it on the neutral or ground wires. Otherwise, the component could still be receiving live current even when the switch is turned OFF.
• Do not use this switch in wet or damp locations, or near explosive fumes or flammable liquids. It is not sealed or rated for these environments.
• Make sure there is a verified compo­nent ground on the circuit this switch is installed.
Specifications
Rated Voltage ............................125V/250V
Rated Current ...................................... 6A
COPYRIGHT © MAY, 2014 BY WOODSTOCK INTERNATIONAL, INC.
WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT
THE WRITTEN APPROVAL OF WOODSTOCK INTERNATIONAL, INC.
D4532 Wide Single Mini ON/OFF Switch
Installation
When installing the D4532 switch, use the wiring diagram in Figure 2 to ensure proper wire connections.
This switch is intended to be connected to stranded wire with insulated quick-discon­nect crimp-type female wire terminals hav-
1
ing a
All crimps must be "pull-checked" to ensure that wires are securely crimped and will not fall out with moderate tension or when exposed to normal machine vibration.
4" tab.
Power Source
Hot
In
ON
Rear View
(|)
of Switch
OFF
(O)
Hot Out
Component
KEDU HY39
Verified Ground*
Figure 2. D4532 wiring diagram.
*The component MUST be connected to a verified ground. In the event of certain malfunctions or breakdowns, grounding reduces the risk of electric shock by providing a path of least resistance for electric current.
-2-