Model D4531
Double Mini ON/OFF
Switch
Instruction Sheet
Phone #: (360) 734-3482 • Online Tech Support: tech-support@shopfox.biz • Web: www.shopfox.biz
To reduce risk of serious burns, electrocution or death when installing this switch:
• Only use this switch to replace an existing component switch that has the same
physical configuration and equivalent
electrical specifications/ratings.
• Installation must only be performed by an
electrician or qualified service personnel,
and all applicable electrical codes must
be adhered to.
• Turn OFF and completely disconnect all
power sources to the component before
installing the switch.
Figure 1. D4531 Double Mini ON/OFF Switch.
Introduction
The Model D4531 features two ON/OFF toggle
switches in one assembly that operates two
separate circuits. This assembly fits into a
7
⁄8" rectangular hole.
3
⁄4" x
• Only install this switch on the "hot" wires.
Do not install it on the neutral or ground
wires. Otherwise, the component could
still be receiving live current even when
the switch is turned OFF.
• Do not use this switch in wet or damp
locations, or near explosive fumes or
flammable liquids. It is not sealed or
rated for these environments.
• Make sure there is a verified component ground on the circuit this switch is
installed.
Specifications
Rated Voltage ............................125V/250V
Rated Current at 125V ...........................10A
Rated Current at 250V ............................ 6A
COPYRIGHT © MAY, 2014 BY WOODSTOCK INTERNATIONAL, INC.
WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT
THE WRITTEN APPROVAL OF WOODSTOCK INTERNATIONAL, INC.
Printed in China
Installation
When installing the D4531 switch, use the wiring
diagram in Figure 2 to ensure proper wire
connections.
This switch is intended to be connected to
stranded wire with insulated quick-disconnect crimp-type female wire terminals hav-
1
ing a
⁄4" tab.
D4531 Double Mini ON/OFF Switch
Rear View of Switch
Power Source 1 Power Source 2
Hot
In
ON
(|)
OFF
(O)
HY39-2
Hot
Out
ON
(|)
OFF
(O)
All crimps must be "pull-checked" to ensure
that wires are securely crimped and will
not fall out with moderate tension or when
exposed to normal machine vibration.
Verified
Ground*
Component 1
Verified
Ground*
Component 2
Figure 2. D4531 wiring diagram.
*The component MUST be connected to
a verified ground. In the event of certain
malfunctions or breakdowns, grounding reduces
the risk of electric shock by providing a path of
least resistance for electric current.
-2-