Shop fox D4166 User Manual

Model D4166
#16597TS
Safety Locking ON/OFF
Switch
Instruction Sheet
Phone #: (360) 734-3482 • Online Tech Support: tech-support@shopfox.biz • Web: www.shopfox.biz
To reduce risk of serious burns, electrocution or death when installing this switch:
• Only use this switch to replace an existing machine switch that has the same physical configuration and equivalent electrical specifications/ratings.
Safety
Key
• Installation must only be performed by an electrician or qualified service personnel, and all applicable electrical codes must be adhered to.
• Turn OFF and completely disconnect all power sources to the machine before installing the switch.
• Do not use this switch in wet or damp locations, or near explosive fumes or flammable liquids. It is not sealed or rated for these environments.
• Make sure there is a verified machine ground on the circuit this switch is installed.
Figure 1. D4166 Safety Locking ON/OFF Switch.
Introduction
The Model D4166 features a large ON/OFF paddle with a removable safety key that can be used to disable the switch. This switch is designed to fit into or be mounted over a 1 hole with four #5 screws.
7
8" x 1 1⁄2" rectangular hole
1
8" x 2 1⁄4" rectangular
Specifications
Rated Horsepower ................................2HP
Rated Voltage ............................ 125V/250V
Rated Current Amperage ........................ 20A
COPYRIGHT © MAY, 2014 BY WOODSTOCK INTERNATIONAL, INC.
WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT
THE WRITTEN APPROVAL OF WOODSTOCK INTERNATIONAL, INC.
D4166 Safety Locking ON/OFF Switch
Installation
When installing the D4166 switch, use the wiring diagram in Figure 2 to ensure proper wire connections.
This switch is intended to be connected to stranded wire with insulated quick-discon­nect crimp-type female wire terminals hav-
1
ing a
All crimps must be "pull-checked" to ensure that wires are securely crimped and will not fall out with moderate tension or when exposed to normal machine vibration.
4" tab.
Machine
Verified
Ground*
Operation
To turn the switch ON, make sure the safety key is properly inserted, then flip the paddle up.
To turn the switch OFF, flip the paddle down.
To disable the switch, turn the switch OFF, then pull the yellow key from the switch and store it in a well hidden or secure location.
Hot Out
Out
125V Neutral
or 250V Hot
Rear View
KEDU
Hot
In
Power Source
125V Neutral
or 250V Hot
HY18-XX
In
of Switch
Figure 2. D4166 wiring diagram.
*The machine MUST be connected to a verified ground. In the event of certain malfunctions or breakdowns, grounding reduces the risk of electric shock by providing a path of least resistance for electric current.