Date : Mar. 9,1999
Copier: SF-2050/2052
1. Change of angle in the discharge cabinet stop
position (Improvement of workability)
2. Change of software for mirror motor
1. Change of discharge cabinet opening/closing/moving form
1. Model Name: SF-2050/2052
No. : SP-2354
2. General: In order to improve the workability, the angle of discharge unit and discharge tray in the opened
state is changed as shown in the following figures.
SHARP CORPORATION Reprography Division
1/3
Green
C
3. Action: From the 1st unit of production in January, 1999
2/3