SHARP SP2348 Technical Report

COPIER : SF-2052
Date
:
Feb. 19, 1999
No. : SP-2348
MEASURE CARRIED OUT TO ALLEVIATE PROBLEMS OF U3-20 TROUBLE.
1.Model Name: SF-2050/2052
2.General: There were problems of U3-20 trouble occurring during Chinese (SOCC) production,
when the power supply of the machine was turned ON, due to the 2/3 mirror becoming attached to the cushion even if the 2/3 mirror fixing screw was disengaged. This was caused by the fact that the affixing strength of the 2/3 mirror fixing screw was too strong. As a measure to alleviate this problem, a change has been carried out in the fixing screw. The new fixing screws are longer than the old ones, and this has enabled a lesser force to be exerted on the 2/3 mirror in the direction of the paper delivery side.
3.Action: * (For machines bound for the Chinese market)
- Chinese (SOCC) production: From 1998 mid-December production.
(For machines bound for the Chinese market)
- Japanese domestic production: From 1998 mid-November production.
(For all machines bound for markets other than the Chinese market)
- Running change carried out from 1999 January production.
Ref.
Model
No.
SF-2050 SF-2052
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type.
3. Current type cannot be used in place of new type.
Parts marked with ‘ ’’ is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Version P/G No.
name
All 48 -21 LX-BZ0649FCZZ LX-BZ0163FCZZ AB 2/3 mirror fixing screw * 3
New type cannot be used in place of current type.
New type can be used in place of current type.
Current parts New parts
Parts code Parts code
Effec-
Price
rank
5. Interchangeable if replaced with same types of related parts in use.
6. Others.
Parts name
tive
time
Inter-
change-
ability
Note
SHARP CORPORATION Reprography Division
Green
C
Loading...