Sharp SJ-P43N-SL, SJ-43N-BE, SJ-P47N-SL, SJ-47N-BE Service Manual

1
SJ-P43N/43N SJ-P47N/47N
SERVICE MANUAL
S6516SE47ATUFT
SHARP CORPORATION
TABLE OF CONTENTS
page
SPECIFICATIONS ............................................................................................................................................3
DIMENSIONS ...................................................................................................................................................6
LIST OF ELECTRICAL PARTS ........................................................................................................................9
WIRING DIAGRAM.........................................................................................................................................10
FUNCTIONS ...................................................................................................................................................14
ASSEMBLING PROCEDURES OF MAIN PARTS AND CAUTIONS .............................................................18
COOLING UNIT ..............................................................................................................................................25
REPLACEMENT PARTS LIST .......................................................................................................................27
Refrigerant; HFC-134a
Refer to "HFC-134a COOLING UNIT" Service Manual for handling this refrigerant.
DESTINATION .........................F
In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its original condition and only parts identical to those specified should be used.
REFRIGERATOR-FREEZER
MODELS
SJ-P43N-SL SJ-43N-BE SJ-P47N-SL SJ-47N-BE
SJ-P43N SJ-P47N
SJ-43N SJ-47N
2
SJ-P43N/43N SJ-P47N/47N
Some household cleaning chemicals may affect the internal food liner and plastic parts resulting in splitting or cracks occurring. When cleaning all plastic parts inside this refrigerator, only use diluted dishwashing liquid(soapy water). Make sure that all plastic parts are thoroughly rinsed with water after cleaning.
CAUTIONS AND INFORMATIONS
1. Some foods froze in the refrigerator compartment.
2. Some plastic parts were cracked or split.
Cracking or crunching sound;
Sound produced by expansion and contraction of inner walls and internal parts during cooling.
Squeaking sound;
Sound produced by expansion and contraction of internal parts.
Sound of flowing fluid (gurgling sound, fizzing sound);
Sound of refrigerant flowing in pipes (sound may become louder from time to time).
3. IT IS NORMAL for the refrigerator to produce the following sounds.
Do not place food directly in front of cold air outlet. This may lead to the food freezing.
IN OUT
cold air flow
In case of following troubles, the cause is not related with the failure of refrigerator. Please mention the correct way to the customer for the use of refrigerator when the repairing.
3
SJ-P43N/43N SJ-P47N/47N
SPECIFICATIONS
Items SJ-P43N SJ-43N SJ-P47N SJ-47N Type 2-Door 2-Door Outer dimensions Height 1700mm(66.9") 1820mm(71.7") (Including spacer) Width 680mm(26.8") 680mm(26.8")
Depth 660mm(26.0") 660mm(26.0") Rated storage volume 347 liter (12.3cu.ft) 384 liter (13.6 cu.ft) (Rated volume) F: 99liter (3.5 cu.ft) F: 99 liter (3.5 cu.ft)
R: 248 liter(8.8 cu.ft) R: 285 liter(10.1 cu.ft)
Gross volume 370 liter (13.1cu.ft) 407 liter (14.4 cu.ft)
F: 107liter (3.8 cu.ft) F: 107 liter (3.8 cu.ft) R: 263 liter(9.3 cu.ft) R: 300 liter(10.6 cu.ft)
Defrosting System Heater system
Start Automatic
Finish Automatic Temperature control Automatic (Adjustable) No-frost freezer Yes Interior lamp 1 Caster 2 Evaporating pan 1 Refrigerator R glass shelf ass'y 2 - 2 ­Compartment Refrigerator tray(plastic) - 2 - 2
V glass shelf ass'y 1 - 1 -
Vegetable tray(plastic) - 1 - 1
Vegetable case 1
V parting plate 1
R door pocket 1
Egg tray 1
R door pocket S 2
Bottle pocket 1
Bottle stopper 1
Door pocket 1
Fresh case 1 Freezer Freezer tray 1 Compartment Ice cube maker Twin ice cube maker
Ice storage box 1
Door pocket 2 Deodorizing unit 2 ( Honeycomb type) Plasmacluster Yes No Yes No
RATING
Items SJ-P43N SJ-43N SJ-P47N SJ-47N Rated voltage (V~) 110 Rated frequency (Hz) 60 Climate class ST Rated input (W) 129 Rated input of heating elements (W) 128 Refrigerant (Charging quantity) [Non-flammable]
HFC-134a(105g)
Insulation Blowing Gas
[Flammable]
Cyclo pentane (HC)
Net Weight (kg) 70 66 72 68
PLUG TYPE
Plug cord 2 pin Plug type A-1
Destination mark F
4
SJ-P43N/43N SJ-P47N/47N
COLOR
Items -BE -SL Outside color Beige Silver Inside color White
5
SJ-P43N/43N SJ-P47N/47N
DESIGNATION OF VARIOUS PAR TS
Upper hinge cover
Hot pipe
Freezer temp. control knob
Hot pipe
Foot cover
Adjustable leg ass’y
Fan motor Defrost thermostat Evaporator Defrost heater
Damper thermostat
Ionizer (Only for SJ-P43N,SJ-P47N)
Refrigerator temp. control knob Drain pipe
Vegetable case
Compressor Starting relay, Overload relay(Protector)
Caster
Freezer compartment
Refrigerator compartment
Mark: Cold air flow
Evaporating pan
Defrost timer
Panel P.W.B
(Only for SJ-P43N,SJ-P47N)
Main P.W.B (Only for SJ-P43N,SJ-P47N)
The names in parenthesis are the denominations used in the REPLACEMENT PARTS LIST.
1. Freezer temp. control knob
2. Freezer shelf(Freezer tray)
3. Ice cube maker
4. Ice cube box(Ice storage box)
5. Deodorizing unit
6. Fresh case
7. Refrigerator temp. control knob
8. Light(Lamp)
9. Refrigerator shelf
(R grass shelf ass'y / Refrigerator tray)
10. Lever (V-tray control knob)
(Only for SJ-43N,SJ-47N)
11. Shelf
(V grass shelf ass'y / Vegetable tray)
12. Vegetable crisper(Vegetable case)
13. Divider(V parting plate)
14. Evaporating pan
15. Casters
16. Foot cover(Ventilating grille)
17. Adjustable feet(Adjustable leg ass'y)
18. Fan switch
19. Fan & light switch
20. Utility pocket(Door pocket)
21. Magnetic door seal(Door packing)
22. Egg holder(Egg tray)
23. Egg pocket(R door pocket)
24. Small pocket(R door pocket S)
25. Bottle guard(Bottle stopper)
26. Bottle pocket
27. Plasmacluster panel
(Only for SJ-P43N,P47N)
Figure D-1. External Description
1
2 3
4 5
5
7 8
9
11
10
12 13
14 15 17
16
18 19
20
21
23 24
22
25 26
20 21
6
Plasmacluster
27
Figure D-2. Constructions
6
SJ-P43N/43N SJ-P47N/47N
DIMENSIONS
OUTER DIMENSIONS AND CLEARANCE
Fig. E-1(SJ-P43N,SJ-43N)
Fig. E-2(SJ-P47N,SJ-47N)
680
680
470
660
90
more than
60
more than
60
more than
60
more than
5951022.5
1700
73
16 9.5
1260
1320
1210
(Unit : mm)
1
1: Not include the handle
90
more than
660
60
more than
680
5951142.5
1820
680
470
60
more than
60
more than
73
16
9.5
1260
1320
1210
(Unit : mm)
1
1: Not include the handle
7
SJ-P43N/43N SJ-P47N/47N
INNER DIMENSIONS
The dimensions between shelves can be changed by setting the shelves on the other rails.
Fig. E-3(SJ-P43N)
Fig. E-4(SJ-43N)
502
502
502
321
531
502
518
242
242
510
526
225
232
89
89
112
99
99
246
307
307
349
188
229
210
118
(172.5)
(133)(172)
226
126
82
539
536
536
508.5
(Unit: mm)
502
502
502
321
531
524
524
502
518
242
242
510
526
225
232
89
89
112
99
99
246
269
269
320
188
229
210
118
(168.5)
(125)
(165)
226
126
82
526
508.5
(Unit: mm)
8
SJ-P43N/43N SJ-P47N/47N
(Unit: mm)
502
321
502
502
502
518
531
524
524
526
242
242
510
225
232
89
89
112
99
99
246
269
269
320
188
229
210
118
(218.5)
(175)
(185)
226
126
82
526
628.5
(Unit: mm)
307
349
(183)
(192)
307
(222.5)
536
536
539
502
321
502
502
502
518
531
526
242
242
510
225
232
89
89
112
99
99
246
188
229
210
118
226
126
82
628.5
Fig. E-5(SJ-P47N)
Fig. E-6(SJ-47N)
9
SJ-P43N/43N SJ-P47N/47N
LIST OF ELECTRICAL PARTS
ITEMS TYPE NAME RATING SPECIFICATIONS Thermostat MM1-8149 125V 6A (At normal notch)
250V 3A ON/OFF : -20 / -25˚C Defrost thermostat S101 250V 8A Open/Close : 8 / 1˚C Thermo. fuse SF70E 250V 10A Working temp. : 70˚C Fan motor 3R00171 110-120V 60Hz Working with ø100 fan Defrost heater MM1-4266 115V 94.5 140W at 115V Door switch DSD-5 125V 0.5A 4 terminals push-button type Damper thermostat MM1-6173 Open/Close : 5 / 0˚C Defrost timer TMDFX04FB2 110-127V Integration type
50/60Hz Cycle time : 12h/10h(50/60Hz)
Delay time : 4m48s/4m(50/60Hz) Lamp socket 250V 1A E-12(Hard plastic body type) Lamp 110V 15W E-12 Compressor FL1568PF 110V/60Hz Cooling capacity : 210W (60Hz)
Main coil : 1.99
Aux. coil : 3.27
(at 75˚C)
Starting relay P5T0SAT 5.6 Overload relay(Protector) 3.6C36C1 Open/ Close : 130/60˚C Running Capacitor 250V 14µF— Ionizer-K
(Plasmacluster unit)
FTRN-A014CBKZ DC12V 3.5kV p-p
(Only for SJ-P43N,P47N)
Common
Main coil
Aux. coil
10
SJ-P43N/43N SJ-P47N/47N
WIRING DIAGRAM
Be sure to replace the electrical parts with specified ones for maintaining the safety and performance of the set.
Figure W-1. Wiring Diagram (SJ-P43N,P47N)
Figure W-2. Wiring Diagram (SJ-43N,47N)
11
SJ-P43N/43N SJ-P47N/47N
Figure W-3. Electric Accessories Layout (SJ-P43N,P47N)
Cabinet ass’y
E.V. cover ass’y
Lead EV-cover ass’y
Fan motor
F-thermostat
Def thermo. ass’y
Fuse ass’y
FM
Def. heater ass’y
Door switch
2 (PUSH OPEN)
3 (PUSH CLOSE)
4 (PUSH OPEN)
1 (NEUTRAL)
1
2
1
2
1
2
1
2
1
2
3
4
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
GY-1
OR-1
R-1
BR-1
Y-1
W-1
BL-1
BL-2
BR-2
SB-1
(SB-1)
BK-1
(W-1)
Y-2
(OR-1)
R lamp box ass’y
Lamp 15W
Lamp socket
L
GY
BR
OR
Y
R
P
BL
BK
SB
G-Y
W
: GRAY
: BROWN (live)
: ORANGE
: YELLOW
: RED
: PINK
: BLUE (neutral)
: BLACK
: SKY-BLUE
: GREEN-YELLOW (earth)
: WHITE
1
2
3
4
OR-4
BR-6
BL-3
GY-3
PWB
HARNESS
MAIN
PWB
1
2
3
1
2
1
2
1
2
1
2
1
2
CLUSTER
HARNESS PU
CLUSTER
HARNESS
Plasmacluster unit
(Ionizer-K)
1
2
3
1
2
3
CAB
HARNESS
1
2
3
PANEL
PWB
F-Door
DOOR HARNESS
BL
1
2
3
4
1
2
3
4
Terminal box Terminal box B
TM
Defrost timer
(Y-1)
(Y-2)
(R-1)
(BK-1)
GY-2
Compressor
C
M
A
Starting
relay
Source plug / cord
BROWN
BLUE
GRAY
ORANGE
Terminal block
Overload relay
(Protector)
1
Running capacitor
12
SJ-P43N/43N SJ-P47N/47N
Figure W-4. Electric Accessories Layout (SJ-43N,47N)
Cabinet ass’y
E.V. cover ass’y
Lead EV-cover ass’y
Fan motor
F-thermostat
Def thermo. ass’y
Fuse ass’y
FM
Def. heater ass’y
Door switch
2 (PUSH OPEN)
3 (PUSH CLOSE)
4 (PUSH OPEN)
1 (NEUTRAL)
1
2
1
2
1
2
1
2
1
2
3
4
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
GY-1
OR-1
R-1
BR-1
Y-1
W-1
BL-1
BL-2
BR-2
SB-1
(SB-1)
BK-1
(W-1)
Y-2
(OR-1)
R lamp box ass’y
Lamp 15W
Lamp socket
L
GY
BR
OR
Y
R
P
BL
BK
SB
G-Y
W
: GRAY
: BROWN (live)
: ORANGE
: YELLOW
: RED
: PINK
: BLUE (neutral)
: BLACK
: SKY-BLUE
: GREEN-YELLOW (earth)
: WHITE
BL
1
2
3
4
1
2
3
4
Terminal box
TM
Defrost timer
(Y-1)
(Y-2)
(R-1)
(BK-1)
GY-2
Compressor
C
M
A
Starting
relay
Source plug / cord
BROWN
BLUE
GRAY
Terminal block
Overload relay
(Protector)
1
Running capacitor
13
SJ-P43N/43N SJ-P47N/47N
Figure W-5. Circuit Diagram (Only for SJ-P43N,P47N)
1
2
3
4
5
6
7
8
9
10
11
12
13
1. Resistance which is not specified : 5% 1/8W
2. Rated voltage of
thecondenser
which is not specified : 25V
[ NOTE ]
5
3
7
1
1
1
3
2
2
1
3
2
CN1
CN3
CN2
CN4
SW
2A
2A
F-FM
PC
(PANEL PWB)
(MAIN PWB)
(A/D)
D5
D4
R1 R2 R3
R5
2.2K
R21
(1/2W)
680
C7
0.1
R4
10K
R7
1K
R12
2.2K
R10
2.2K
R8
10K
4.7K R20
1M R6
RS1
RS2
RS3
R18
10K
R14
1K
R16
10K
R17
(1/2W)
1.8
R11
1K
R9
1K
R13
4.7K
R15
4.7K
PC1
PC123
CF1 CST4.00MGW
TMP47C241N
INPUT VOLTAGE
D6
D3
VRS1
C13
0.1
C15
100
10V
C10
1
50V
C9
0.1
VRS2
Q7
KRA101M
Q5
KRA101M
Q4
KRC101M
Q3
KTA1046
Q6
KRA101M
Q1
KRA101M
Q2
KRC101M
C2
2200
35V
R19
OPEN
C16
0.1
C18
0.1
C19
1000
25V
C8
0.1
C6
0.1
C4
0.1
C20
100
10V
C17
100
10V
12V
12V
12V
5V
G
IIOO
G
HS
IC2IC1
IC4
7812 7805
C3
0.1
50V
TRNS IN4005E
PST993E
IC3
D1
IN4007E
D2
ISS270A
D7
ISS270A
ZD1
LED1
C1
0.1
C11
0.1
C12
0.1
C5
1
50V
13
2
VAREF
R40(AINO)
R41(AIN1)
R42(AIN2)
R43(AIN3)
R71(WT0)
R80(INT2)
R81(T2)
R82(INT1)
P10
P11
P12
P13
VSS
VDD
K03
K02
K01
K00
HOLD
RESET
XOU
XIN
TEST
R92
R91
R90
P20
220 240V
120V
110 120V
RS1,2,3=43K(1/2W), RS3=OPEN, VRS1,2=560V
RS1,2,3=18K(1/2W), RS3=10K(1/8W), VRS1,2=270V
RS1,2,3=18K(1/2W), RS3=SHORT,
VRS1,2=270V
250V
PC
:
PLASMACLUSTER UNIT
(IONIZER-K)
14
SJ-P43N/43N SJ-P47N/47N
FUNCTIONS
1. ADJUSTABLE TEMPERATURE CONTROL (1) Temperature control of freezer
Thermostat (senses freezer temperature) operates on ON/OFF switchover to control the compressor and cool air circulating fan , and allows the freezer temperature to keep at a suitable temperature. However adjust the freezer temp. control knob as follows depending upon the storing condition of foods.
KNOB SETTING
MAX
(Coldest)
MIN
PURPOSE
For making ice rapidly or fast freezing.
For storing frozen food for a short period (up to one month). When frozen food or ice cream is not stored.
For normal freezing.
MED
When restocking with fresh food.
KNOB SETTING
MED
Coldest
MIN
PURPOSE
For keeping freshness of food longer.
For normal operation. When the refrigerator provides excessive cooling.
When the refrigerator does not provide sufficient cooling.
The values shown above refer to the measurement carried out center area and 1/3 of overall height from the bottom at each of the refrigerator and the freezer after machine has been operated at an ambient temperature of 30˚C with no food stored and the door closed until the temperature is stabilized. The values vary depending upon frequency of opening and closing the door, ambient temperature, amount of stored foods and manner of storing foods.
SETTING OF REFRIGERATOR TEMP. CONTROL KNOB
Refrigerator temperature
Fresh case temperature
Coldest MED MIN
Approx.
0˚c
Approx.
-3˚c
Approx.
3˚c
Approx.
1˚c
Approx.
6˚c
Approx.
4˚c
The values shown above refer to the case where the freezer temp. control knob is set at "MED".
Figure F-2.
NOTE: The refrigerator temperature is affected also by the freezer temperature. If the freezer temp.
control knob is set at the position "MAX", the temperature tends to be lower than the following values, and if set at near the position "MIN", temperature tends to be higher. If the refrigerator is operated for a long time with the freezer temperature control sets the "MAX" position, foods stored in the refrigerator compartment may also freeze. When refrigerator temperature control sets to the "Coldest", some foods stored may freeze. In this case adjust control set back to the "MED" position. When refrigerator temperature control sets to the "Coldest", some foods stored in Fresh case may also become frozen.
(3) Reference value of temperature
SETTING OF FREEZER TEMP. CONTROL KNOB
Freezer temperature
MAX
(Coldest)
MED MIN
Approx.
-21˚C
Approx.
-18˚C
Approx.
-15˚C
Figure F-1.
(2) Temperature control of refrigerator
Damper-thermostat senses temperature of the refrigerator and changes the opening angle of the damper automatically. However, as the Damper-thermostat has no function to switch on or off the compressor and fan motor, the freezer temperature control causes temperature in the refrigerator to vary to some extent. However, adjust the refrigerator temp. control knob as follows depending upon the cooling condition.
15
SJ-P43N/43N SJ-P47N/47N
(2) Where is melted frost brought
1. Melted frost is brought into the evaporating pan at the back of the set and is evaporated here by the heat of compressor.
2. Be sure to use Evaporating pan as inserted so as to be level with the outer case.
2. DEFROSTING (1) No defrosting operation is necessary
No defrosting operation is necessary. As this machine is so designed that a built-in evaporator cools air and a fan circulates cooled air, neither the freezer nor the refrigerator is frosted, though the evaporator is frosted. The frosted evaporator is defrosted automatically due to the function of defrosting timer and heater, requiring no defrosting operation.
(3) The following circuit diagrams in the table show automatic defrosting function of the refrigerator with
timer and defrost thermostat.
Operation Electric diagram Description
1. Cooling (Normal)
2. Defrosting
(Time 20 to 30 min.)
3. Drain
(Time approx. 5 min.)
4. Restart
(Time approx. 5 min.)
The integration timer integrates running time of the compressor. When it reaches cycle time of defrost timer, the timer contact is changed to start defrosting.
When the defrost thermostat becomes OFF, the timer motor starts running. During the operation time (delay time of defrost time)
defrosted water is
drained outside the refrigerator.
Timer contact is changed to cooling operation and the compressor starts running and the timer motor stops. Defrost thermostat contact becomes ON when it’s cooled. And the timer motor starts running. (Figure F-3.)
Figure F-3.
Figure F-4 .
Figure F-5.
Figure F-6.
TM COMP
Defrost thermostat ON Compressor running
Timer motor running
Timer contact
Defrost thermostat (ON)
Defrost heater
Thermo. fuse
Compressor
Timer motor
SOURCE
TM COMP
Defrost thermostat OFF Compressor running
Timer motor stops
Thermostat Timer contact
Defrost thermostat (OFF)
Defrost heater
Thermo. fuse
Compressor
Timer motor
SOURCE
TM COMP
Defrost thermostat OFF Compressor stops
Timer motor running
Thermostat Timer contact
Defrost thermostat (OFF)
Defrost heater
Thermo. fuse
Compressor
Timer motor
SOURCE
TM COMP
Defrost thermostat ON Compressor stops
Timer motor stops
Thermostat Timer contact
Defrost thermostat (ON)
Defrost heater
Thermo. fuse
Compressor
Timer motor
SOURCE
Thermostat
The timer contact is changed to start defrosting, the timer motor stops, and power is supplied to the defrost heater. It takes about 20 to 30 min. to defrost. When little frosted, the defrosting takes little time. When much frosted, the def­rosting takes much time.
16
SJ-P43N/43N SJ-P47N/47N
(4) As a reference to determine the causes of trouble, malfunction and phenomena are described below.
Refer to the following when repairing.
1. Disconnection of defrost heater
As off-cycle defrosting is performed, the defrosting time is extremely prolonged. Each time defrosting is started, the freezer temperature rises and a portion of ice and stored foods are melted.
2. Melted thermo. fuse or opened-circuit due to the defect of defrost thermostat.
When the above mentioned trouble occurs in cooling operation, the timer motor does not run, defrosting will not take place, and consequently freezing is caused. In the above mentioned condition, when the timer shaft is turned by hand to defrost, the timer motor runs during the operation time. However, the motor stops from the time when the contact is changed, and freezing causes.
NOTE:
As the thermo. fuse assembly is intended to prevent dangers, do not use it under shorted condition even for a short period.
3. DEW PREVENTION
The hot pipe, namely D.P.-condenser, is arranged around the flange part of cabinet and the C-partition plate, preventing dew from being generated on the cabinet.
NOTE:
D.P.-condenser pipe may be felt hot if touched by hand while the compressor is in operation. If you are asked about this, please explain that the hot pipe serve to prevent the dew generation.
Figure F-7
4. INSPECTION OF INITIAL STARTING (1) Inspection of cooling unit
1. Set the temperature control knob to "MAX" and check that the compressor starts to operate.
2. Depress the door switch to run the fan and check that cool air is blown out of the cold air outlet of the freezer and the refrigerator.
3. When the compressor does not work, check that the timer is not set to "defrost" position.
4 It takes about an hour and a half or two hours to put food in the refrigerator after starting operation.
NOTE:
After return the temperature control knob to "MED" position. When the refrigerator is operated initially after installed, the compressor may vibrate excessively for 1 to 2 min. However, vibration becomes normal if it is continuously operated.
(2) Inspection of defrost device
Operate the refrigerator for 20 to 30 min. and then check the defrost device in the following procedures : Allow 5 min. to restart the compressor since immediate starting after stopping will cause unsmooth operation.
1. Turn the timer shaft clockwise with a screw driver. At this time, make certains the timer clinks and the compressor stops.
2. After more than 5 min., turn the shaft further to operate. Make certain cooling operation is started again.
Hot pipe
17
SJ-P43N/43N SJ-P47N/47N
5. PLASMACLUSTER (Only for SJ-P43N,P47N) (1) Plasmacluster is what thing.
The ionizer inside the refrigerator will release cluster ions, which are collective mass of positive and negative ions, into the the freezer and refrigertor compartments. The cluster ions inactivate airborne fungus.
(2) Plasmacluster Panel
1.When the refrigerator will be operated, the
Plasmacluster
lamp of the
panel will light up.
2.By pushing the button, the lamp goes out or lights up.
3.Under the lamp is lighting, Plasmacluster operation is controlled as follows.
(3) Plasmacluster Control.
1.Plasmacluster operation will be performed when the following conditions gather.
1) Lamp : Under lighting
2) Compressor : Under operation
3) Door : Closed
4) Within
"
The Plasmacluster operation time".
2.If the sum total of Plasmacluster operation time will reach at the set time (
"The Plasmacluster operation Time"
) ,
Plasmacluster operation will stop.
3.
After an operation stop, the
Plasmacluster
will be not operated during the set time ("The Plasmacluster operation
compulsive stop time"
) .
Time chart A
Compressor               
ON
Fan motor   
Door
Plasmacluster
t1 t2 t3
Time chart B
Compressor               
Fan motor            
Door
Plasmacluster
        t1 t2 t3
Plasmacluster
Plasmacluster panel
Lamp
Button
The Plasmacluster operation time = t1 + t2 + t3
18
SJ-P43N/43N SJ-P47N/47N
ASSEMBLING PROCEDURES OF MAIN PARTS AND CAUTIONS
CAUTION: DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY REPAIRING.
1. R-AIR GUIDER ASSEMBLY
Figure A-1
After forming, fix it to the refrigerator.
Less than 160 mm
Damper thermostat
5
1
mm
8
1
mm
Less than 12 mm
NOTE Minimum bending radius is R5mm. There should be no gas leak by reforming of sensor tube.
++
Figure A-2
(1) Forming sensor of Damper thermo.
(2) Setting R air guider S (Only for SJ-43N,47N) and sticking sealers to R air guider.
R air guider
R air guider S
A-sealer ag1A-sealer ag1
Masking tape
A-sealer ag3
A-sealer ag2A-sealer ag2
Dial sealer
R air guider
A-sealer ag1
A-sealer ag1
OVERLAP AREA
OVERLAP 8mm
OVERLAP 15mm
OVERLAP 15mm
DATUM
DATUM
DATUM
(Only for SJ-43N,47N)
Figure A-3
Damper thermo.
A-sealer ag3
A-sealer ag2
Dial sealer
R air guider
R air guider S
Ionizer-K
Plasma holder
Plasma harness
A-sealer ag1
(Only for SJ-P43N,P47N)
(Only for SJ-43N,47N)
19
SJ-P43N/43N SJ-P47N/47N
(3) Fixing of the Ionizer-K.(Only for SJ-P43N,P47N)
(3)-1 Connect Ionizer-K and connector of the lead wire. (3)-2 Insert Ionizer-K to Plasma holder. (3)-3 Insert the (3)-2 assembly to R air guider A.
2P
2P
2P
2P
Ionizer-K
R air guider A
Plasma harness
Paper tape W30×100mm
Paper tape W30×40mm
Paper tape W30×40mm
Plasma holder
Ionizer-K
Plasma harness
Connector should insert surely.
SEC. A—A
SEC. B—B
A
B
B
A
20
SJ-P43N/43N SJ-P47N/47N
(2) Fixing of Fan motor and Fan
(2)-1 Stick U-sealer handle to Fan motor holder A.
Figure A-6
2. FAN LOUVER AND E.V COVER ASSEMBLY
Figure A-4
E.v cover sealer C
E.v cover sealer C
Fuse ass’y
F-thermostat
E.v cover
Defrost thermo. ass’y
E.v cover sealer A
E.v cover sealer G
L-band C
L-band C
Lead EV-cover ass’y
U-sealer handle
Fan motor holder A
Fan clamp
Propeller fan 100
Fan motor holder B
Fan motor
Motor cushion
E.v cover sealer B
E.v cover sealer D
E.v cover sealer E
E.v cover AL A
E.v cover sealer F
Fan motor holder A
U-sealer handle
U-sealer handle
7 2mm
+
+
0 1mm
C
C
SEC. C-C
E.v cover sealer C
E.v cover sealer G
E.v cover sealer A
E.v cover sealer B
E.v cover
[back side]
STICK START
STICK START
STICK START
(1)
(1)
(2)
(3)
(3)
(4)
(4)
(4)
Screw
Fan louver
Screw
Claw
Claw
Claw
Claw
2-1. How to remove the Fan louver
(1) Take out 2 screws. (2) Insert the screwdriver into the air hole of the Fan
louver.
(3) Press the Fan louver to the left side with the
screwdriver,and pull it toward yourself to take off the Fan louver.
2-2. E.v cover assembly
Figure A-5
Figure A-7
(1) Sticking of Sealers to E.V cover
21
SJ-P43N/43N SJ-P47N/47N
(2)-4 Set Fan clamp to Propeller fan 100 and insert
it to the shaft of Fan motor.
(2)-2 Insert the terminals of Lead EV-cover ass'y to
Fan motor.
(2)-3 Fix two Motor cushions to Fan motor, and set it
at Fan motor holder A and B. Then fix with Tapping screw.
Figure A-8
(3) Setting of Fan motor ass'y , Defrost thermo. ass'y and Fuse ass'y.
Fan motor holder A
Fan motor holder B
Motor cushion
Tapping screw
Fan motor
Lead EV-cover ass’y
RED
BROWN
Fan clamp
Propeller fan 100
Fan clamp
Slit
Slit of each Fan clamp and Propeller fan should not be at same position.
Shaft
4 0.5mm
+
Detail of D
D
Note Propeller fan should not be taken out from shaft when pulled by 3 kgf.
×○
Fan clamp
Propeller fan
Figure A-10
[front side]
more than 3.5mm more than 3.5mm
Lead e.v cover ass’y
E.v cover sealer C
Take out lead wire from square hole to front and fix with L-band C, then seal with E.v cover sealer C
Aluminum tape
Aluminum tape
Aluminum tape
Aluminum tape
Tapping screw
Set metal side below
L-band C
L-band C
L-band C
Fuse ass’y
[back side]
Defrost thermo. ass’y
Tapping screw
E.v cover
F
G
F
H
H
Defrost thermo. ass’y
CUT
Not come out of claw.
10 5mm
+
SEC. F F
Turn up lead wire
ATTENTION
SEC. H H
Fuse ass’y
E.v cover sealer E
Detail of G
E.v cover sealer E
[Front side]
E.v cover AL A
E.v cover sealer F
Figure A-9
22
SJ-P43N/43N SJ-P47N/47N
50mm
8.5mm
21mm
R10mm
R10mm
(5) Setting of F-thermostat
(5)-1 Form capillary tube of F-thermostat.
Note
• Bending radius of capillary tube should be
from R5mm to R10mm.
Figure A-13
(5)-3 Set to E.V cover.
Stick E.v cover sealer D.
(5)-2 Insert terminal of Lead EV-cover ass'y.
After inserting, fix with vinyl tape.
Figure A-11
1234
5678
F-thermostat 2
F-thermostat 6 (BROWN, inserted)
Fuse 8 (BLACK)
Fuse 8 (WHITE)
Fan motor 1 , 5
(RED, inserted)
Defrost thermo. 3 (PINK)
Defrost thermo. 7 (BLUE)
WIRE COLOR FOR FAN MOTOR
100-110V : WHITE
127V : YELLOW
220-240V : BLUE
Note Pins should be inserted surely, and check by pulling it.
Figure A-12
Vinyl tape
Figure A-14
Figure A-15
RED
BROWN
(front side)
(back side)
F-thermostat
SEC. B B
B
B
E.v cover sealer D
(4) Inserting of pins
23
SJ-P43N/43N SJ-P47N/47N
Fig. A-16
(1)-2. As shown in Fig. A-17, pull the upper part of
Evaporator toward you, pull it diagonally so that the pipe of Evaporator does not contact the convex part of food liner.
3. DEFROST HEATER
(1) Taking-out Evaporator
(1)-1. Take out E.v cover ass'y (Fig. A-16).
Evaporator
Food liner convex part
Food liner convex part
Evaporator
Pipe
Fig. A-17
(1)-3. As shown in Fig. A-18, bend the removed
Evaporator horizontally so that Defrost heater can be replaced easily.
NOTE: When pulling Evaporator and bending the
pipes, pay attention so as not to break and deform the pipes. Still, take care not to hurt yourself by fin of Evaporator.
Fig. A-18
Evaporator
(2) Replacement of Def. heater ass'y.
(2)-1 Remove the center screw of Drain support al
to take it off from the food liner.
Fig. A-19
(2)-2 Raise the protrusion part of Drain support al.
Then remove Heater cover.
Fig. A-20
(2)-3 Open Def.heater fixed part of Drain support al to
the right and left, then remove Def.heater ass'y.
Screw
Drain support al
Drain support al
Heater cover
Protrusion parts
Protrusion part of Drain support al(2 pcs.)
Heater cover
Def. heater ass’y
Fig. A-21
Fixed parts
Drain support al
Def.heater ass’y
24
SJ-P43N/43N SJ-P47N/47N
Fig. A-26
(2)-9. Wind up Leading wire sealer as shown in Fig. A-27
Fig. A-25
(2)-8. Set Heater cover on Drain support, and bend top
edge c and d to outside as shown in Fig. A-26.
Fig. A-23
(2)-6. Bend a and b of Drain support al to right angle
(90˚) to set Def. heater ass'y. (Fig. A-24)
Fig. A-22
(2)-5. Wind the Glass cloth tape (3M: No. 27) to lead wire
of Def. heater ass'y. (2 places)
(2)-4. Replace Def. heater ass'y with new one. (2)-7. Stick the longer wire to the Drain support by
aluminum tape (2 pieces), and wind vinyl tape (2 pieces) to lead wires of Def. heater ass'y by aluminum tape as shownin Fig. A-25.
Note: Glass cloth tape part shall be both side of Drain
support to protect the lead wire from damaged.
Fig. A-24
Heater cover
Def.heater ass’y
Drain support al
Def. heater ass’y
Glass cloth tape (W40 x L25)
Glass cloth tape Wind the Glass cloth tape more than 2 turns.
360
(40)
(40)50
Lead wire
+
+
5
5
Drain support al
This side is longer wire
This side is shorter wire
Def.heater ass’y
a
b
Glass cloth tape
Glass cloth tape
Glass cloth tape
Glass cloth tape
aluminum tape
(more than 2 turns)
[back side]
[bottom side]
A
A
Sec. AA
(W25 X L40)
Fig. A-27
(2)-10
. Set the assembly above on the food liner by fixing
a screw.
top edge
Drain support al
Heater cover
Heater cover
Def.heater ass’y
Def.heater ass’y
c
d
Sec. BB
B
B
Drain support al
Heater cover
Def.heater ass’y
190 20
+
Leading wire sealer
25
SJ-P43N/43N SJ-P47N/47N
COOLING UNIT
Figure C-1. Cooling unit
Hot pipe L (Side condenser)
Hot pipe (DP-condenser)
Hot pipe R (Side condenser)
Evaporator
Suction pipe
Compressor
Capillary tube
Dryer
Back condenser
Mark: Refrigerant flow Mark: Brazing portion
Eva-pan pipe
(3) Installing of Evaporator (3)-1. Install Evaporator as shown in Fig. A-16 in the
reverse order of Fig. A-17.
(3)-2. Correct the deformed fin.
NOTE
1. When installing Evaporator, take care not to
deform significantly and break the pipes.
2. Take care not to damage the lead wires and hurt
yourself by the fin of Evaporator.
26
SJ-P43N/43N SJ-P47N/47N
From Suction pipe to SP connector
From Compressor to Charge pipe
From Dryer to Capillary tube
From Discharge p connector to Eva-pan pipe ass’y
From SP connector to Compressor
From Compressor to Discharge p connector
From Eva-pan pipe ass’y to Back condenser In
From Back condenser out to Hot pipe
From Hot pipe to Dryer
Figure C-3. Location
Figure C-2. Location
Compressor
Suction pipe
Charge pipe
Charge pipe
Capillary tube
Dryer
Hot pipe
S.P. connector
Eva-pan pipe
Back condenser
Evaporator
27
SJ-P43N/43N SJ-P47N/47N
REF. NO. PART NO. DESCRIPTION Q'TY CODE
REPLACEMENT PARTS LIST(SJ-P43N/43N/P47N/47N)
SJ-P43N SJ-43N SJ-P47N SJ-47N
-SL -BE -SL -BE
ELECTRIC PARTS
1- 1 RTHM-A103CBZZ F-themostat 1 1 1 1 AV 1- 2 RSTT-A176CBZZ Starting relay 1 1 1 1 AS 1- 3 QSWTDA025CBE0 Defrost timer 1 1 1 1 AW 1- 4 PDMP-A050CBEZ Damper thermo 1 1 1 1 AW 1- 5 FTHM-A039CBKZ Defrost thermo.ass’y 1 1 1 1 AM 1- 6 RMOTRA071CBZZ Fan motor 1 1 1 1 AY 1- 7 QSOCAA084CBEZ Lamp socket 1 1 1 1 AL 1- 8 RLMP-A028CBEZ Lamp15w 1 1 1 1 AG 1- 9 QACC-A160CBZZ Source cord 1 1 1 1 AP 1- 10 QSW-PA090CBZA Door switch 1 1 1 1 AS 1- 11 RHOG-A165CBZZ Protector 1 1 1 1 AZ 1- 17 FFS-TA061CBKZ Fuse ass’y 1 1 1 1 AM 1- 20 FW-VZA148CBEZ Lead ev-cover ass’y 1 1 1 1 AL 1- 21 FHETBA164CBEZ Def.heater ass’y 1 1 1 1 AX 1- 22 FCNW-A733CBKZ Relay wire ass’y 1 1 1 1 AP 1- 23 QCNW-A671CBE0 Reray wire rc 1 1 1 1 AD 1- 32 RC-EZA197CBZZ Capacitor 1 1 1 1 1- 33 QCNW-A886CBE0 Olr cord 1 1 1 1 AE 1- 34 QCNW-A887CBE0 Earth wire 1 1 1 1 AG 1- 45 FTRN-A014CBKZ Ionaizer-k 1 - 1 - AZ 1- 46 QCNW-B104CBZZ Plasma harness 1 - 1 - AF 1- 50 FPWB-A347CBKZ Main pwb 1 - 1 ­ 1- 55 FPWB-A336CBKZ Panel pwb ass’y 1 - 1 - AT
MECHANICAL PARTS
2- 2 JKNB-A036CBFC F-temp. control knob 1 1 1 1 AC 2- 4 LANG-A059CBPZ Eva holder 47 2 2 2 2 AC 2- 7 FLEGPA083CBKZ Leg holder l ass’y 1 1 1 1 AF 2- 7- 1 FAJS-A015CBKZ Adjustable leg ass’y 2 2 2 2 AE 2- 7- 2 LHLD-A533CBPZ Leg holder l 1 1 1 1 AL 2- 8 FLEGPA084CBKZ Leg holder r ass’y 1 1 1 1 AF 2- 8- 2 LHLD-A534CBPZ Leg holder r 1 1 1 1 AP 2- 13 DHNG-A437CBMZ Upper hinge ass’y 1 1 1 1 AE 2- 14 DHNG-A419CBMZ Bottom hinge r ass’y 1 1 1 1 AD 2- 15 DHNG-A418CBMZ Center hinge r ass’y 1 1 1 1 AE 2- 16 GCOV-A210CBFZ E.v cover 1 1 1 1 AR 2- 17 LCRA-A022CBPZ Fan clamp 1 1 1 1 AC 2- 19 LHLD-A389CBF0 Motor cushion 2 2 2 2 AF 2- 20 NFANPA011CBF0 Propeller fan 100 1 1 1 1 AD 2- 21 PSEL-C067CBEZ E.v cover sealer a 1 1 1 1 AA 2- 22 PSEL-C068CBEZ E.v cover sealer b 1 1 1 1 AA 2- 23 PSEL-C066CBEZ E.v cover sealer c 1 1 1 1 AC 2- 24 PCOVPA308CBFA Terminal cover 1 1 1 1 AE 2- 26 PCOV-A277CBFA R lamp cover 1 1 1 1 AE 2- 27 GCOVPA144CBRA R-c box cover 1 1 1 1 2- 28 HGRL-A210CBRA Fan louver 1 1 1 1 AU 2- 29 GCOV-A228CBFG Upper hinge cover - 1 - 1 AE 2- 29 GCOV-A228CBFH Upper hinge cover 1 - 1 - AE 2- 31 JKNB-A033CBFC R-temp.control knob 1 1 1 1 AC 2- 32 JKNB-A063CBFA V-tray control knob - 1 - 1 AC 2- 38 PGID-A161CBFZ R-air guider - 1 - 1 AG 2- 38 PGID-A168CBFZ R-air guider 1 - 1 - AK 2- 39 PGID-A162CBFZ R-air guider s - 1 - 1 AC 2- 43 LPLTPA323CBMA Panel base 1 - 1 - AN 2- 44 HGRL-A237CBFA F deodo.louver 1 1 1 1 AE 2- 45 HGRL-A238CBFA R deodo.louver 1 1 1 1 AC 2- 46 PFIL-A050CBEZ Deodorizer 2 2 2 2 AM 2- 47 LHLD-A672CBFZ Plasma holder 1 - 1 - AE 2- 49 LSTPPA108CBFA Chilled stopper 2 2 2 2 AC 2- 50 LSTPPA118CBFA Case stopper v 2 2 2 2 AC 2- 55 HGRL-A205CBFA Multi louver l - - 1 1 AM 2- 55 HGRL-A209CBFA Multi louver s 1 1 - - AM 2- 56 PFPFPB334CBFZ R-louver insu.l - - 1 1 AE 2- 56 PFPFPB345CBFZ R-louver insu.s 1 1 - - AE 2- 57 PSEL-C085CBEZ A-sealer r-louver - - 2 2 AC 2- 57 PSEL-C095CBEZ A-sealer r-louver 2 2 - - AB 2- 63 LHLD-A484CBFA Fan motor holder b 1 1 1 1 AH 2- 64 LHLD-A485CBFA Fan motor holder a 1 1 1 1 AH 2- 65 PSEL-B209CBE0 U-sealer handle 2 2 2 2 AB 2- 66 PSHEMA225CBPZ Heater cover 1 1 1 1 AC 2- 67 LPLTMA633CBPZ Drain support al 1 1 1 1 AF 2- 68 PSEL-A415CBE0 E.v cover sealer c 1 1 1 1 AC 2- 69 PSEL-C069CBEZ E.v cover sealer d 1 1 1 1 AA
28
SJ-P43N/43N SJ-P47N/47N
REF. NO. PART NO. DESCRIPTION Q'TY CODE
SJ-P43N SJ-43N SJ-P47N SJ-47N
-SL -BE -SL -BE
2- 70 PSEL-C135CBEZ E.v cover sealer e 1 1 1 1 AC 2- 71 PSEL-A552CBE0 Dial sealer 1 1 1 1 AC 2- 72 PSEL-C078CBEZ A-sealer ag1 2 2 2 2 AC 2- 73 PSEL-C079CBEZ A-sealer ag2 1 1 1 1 AB 2- 77 LHLD-A359CBFA T-box holder 1 1 1 1 AE 2- 78 LPLTMA399CBP0 Dryer support 1 1 1 1 AD 2- 79 LBND-A019CBE0 Nylon band 1 1 1 1 AB 2- 80 PBOX-A132CBFA Terminal box 1 1 1 1 AF 2- 81 PBOX-A143CBFA Terminal box-b 1 - 1 - AH 2- 82 PCOVPA373CBFA Terminal cover-b 1 - 1 - AN 2- 83 PSEL-C080CBEZ A-sealer ag3 1 1 1 1 AA 2- 87 LBND-A018CBE0 Fastening band a 1 1 1 1 AP 2- 91 HGRL-A202CBFA F return cover 1 1 1 1 AF 2- 93 PCAP-A068CBFA C sliding cap a 4 4 4 4 AC 2- 94 PSEL-C137CBEZ E.v cover sealer f 1 1 1 1 AB 2- 95 PSHEMA231CBEZ Ev cover al a 1 1 1 1 AC 2- 98 LHLD-A504CBE0 Sl-3n clip 1 1 1 1 AD 2- 99 PSEL-A562CBE0 Leading wire sealer 1 1 1 1 AC 2- 100 PSEL-C138CBEZ E.v cover sealer g 1 1 1 1 AA 2- 101 PSEL-C139CBEZ Ev-insulation 47 2 2 2 2 AC
DOOR PARTS
3- 5 FDORFB832CBKZ F-door ass’y 1 - 1 - BS 3- 5 FDORFB839CBKZ F-door ass’y - 1 - 1 BS 3- 5- 1 LSTPPA131CBFA Fd-stopper spring r 1 1 1 1 AD 3- 5- 2 NBRGPA033CBFA Nylon bearing 3f - 1 - 1 AC 3- 5- 3 LSTPMA008CBM0 F-door stopper r 1 1 1 1 AD 3- 5- 4 GDAI-A071CBMZ Badge base - 1 - 1 AK 3- 5- 5 HBDGDA946CBEB Badge - 1 - 1 AN 3- 6 FPACGA346CBKZ F-door packing 1 1 1 1 AT 3- 7 HDECQA475CBMA Hd cap 2 2 2 2 AH 3- 8 HDECQA476CBRA Handle trim f 1 - 1 - AN 3- 8 HDECQA476CBRB Handle trim f - 1 - 1 AQ 3- 9 LPLTMA686CBPZ Hd support f 1 1 1 1 AD 3- 10 LPLTPA374CBFA Handle base f 1 1 1 1 AH 3- 11 HDECQA478CBMA Hd cover ft 1 1 1 1 AM 3- 15 FDORRB639CBKZ R-door ass’y - - 1 - BW 3- 15 FDORRB640CBKZ R-door ass’y 1 - - - BU 3- 15 FDORRB649CBKZ R-door ass’y - - - 1 BU 3- 15 FDORRB650CBKZ R-door ass’y - 1 - - BT 3- 15- 1 LSTPPA084CBFA Rd-stopper spring r 1 1 1 1 AD 3- 15- 2 NBRGPA022CBFA Nylon bearing 3s 1 1 1 1 AC 3- 15- 3 LSTP-A058CBM0 R-door stopper r 1 1 1 1 AF 3- 17 FPACGA347CBKZ R-door packing - - 1 1 AV 3- 17 FPACGA348CBKZ R-door packing 1 1 - - AV 3- 19 HDECQA477CBRA Handle trim r 1 - 1 - AN 3- 19 HDECQA477CBRB Handle trim r - 1 - 1 AR 3- 20 HDECQA479CBMA Hd cover rb 1 1 1 1 AP 3- 21 LPLTMA687CBPZ Hd support r 1 1 1 1 AD 3- 22 LPLTPA375CBFA Handle base r 1 1 1 1 AK 3- 30 GCOVPA177CBRA Panel cover 1 - 1 - BA 3- 31 HBDG-A005CBEA Pc badge 1 - 1 - AH
OTHER PARTS
4- 1 LBND-A023CBE0 L-band c 4 4 4 4 AC 4- 3 LX-VZA022CBZZ Special screw 8 8 8 8 AC 4- 11 QTAN-A012CBE0 Solderless term. b - 3 - 3 AH 4- 12 QTAN-A013CBE0 Solderless term. a 8 - 8 - AH 4- 15 LX-BZA090CBZZ Special screw 3 3 3 3 AC 4- 17 LX-WZA035CBZZ Washer 4 4 4 4 AB
ATTACHMENT PARTS
5- 1 UPOK-A180CBRA Bottle pocket 1 1 1 1 AR 5- 2 UPOKPA268CBFA R door pocket s 2 2 2 2 AH 5- 3 UPOK-A179CBRA Door pocket 3 3 3 3 AM 5- 4 UPOK-A181CBRA R door pocket 1 1 1 1 AL 5- 5 UTNA-A282CBFA Egg tray 1 1 1 1 AH 5- 6 FSRA-A193CBYZ Ice cube maker 1 1 1 1 AS 5- 9 USRA-A270CBFA Freezer tray 1 1 1 1 AT 5- 13 HGRL-A239CBFA Ventilating grille 1 - 1 - AN 5- 13 HGRL-A239CBFB Ventilating grille - 1 - 1 AN 5- 14 USRA-A268CBFA Evaporating pan 1 1 1 1 AM 5- 15 GGAD-A032CBFA V parting plate 1 1 1 1 AG 5- 16 UYOK-A401CBFA Vegetable case 1 1 1 1 AX 5- 17 UYOK-A399CBFA Ice storage box 1 1 1 1 AL 5- 18 UYOK-A400CBFA Fresh case 1 1 1 1 AV
29
SJ-P43N/43N SJ-P47N/47N
REF. NO. PART NO. DESCRIPTION Q'TY CODE
1. MODEL NUMBER 2. REF. NO.
3. PART NO. 4. DESCRIPTION
HOW TO ORDER REPLACEMENT PARTS
To have your order filled promptly and correctly, please furnish the following information.
SJ-P43N SJ-43N SJ-P47N SJ-47N
-SL -BE -SL -BE
5- 19 GDORPA072CBRA Fresh door hs 1 1 1 1 AN 5- 24 FTNA-A394CBKZ R glass shelf ass’y 2 - 2 - AR 5- 24 USRA-A272CBFA Refrigerator tray - 2 - 2 AU 5- 24- 1 UTNA-A377CBEZ Glass shelf r 2 - 2 - AU 5- 24- 2 UWAKPA014CBFA G guard r 2 - 2 - AS 5- 25 FTNA-A395CBKZ V glass shelf ass’y 1 - 1 - AR 5- 25 USRA-A271CBFA Vegetable tray - 1 - 1 AW 5- 25- 1 UTNA-A378CBEZ Glass shelf v 1 - 1 - AW 5- 25- 2 UWAKPA015CBFA G guard v 1 - 1 - AS 5- 31 LRALPA136CBFA Ice tray holder l 1 1 1 1 AG 5- 32 LRALPA137CBFA Ice tray holder r 1 1 1 1 AG 5- 35 UPOKPA269CBFA Bottle stopper 1 1 1 1 AC
CYCLE PARTS
6- 1 PCMPLA220CBEZ Compressor 1 1 1 1 BW 6- 2 PSPAGA042CBE0 Rubber grommet 4 4 4 4 AE 6- 4 FFRM-A119CBKZ Base frame ass’y 1 1 1 1 AH 6- 5 FDRY-A006CBK0 Dryer ass’y 1 1 1 1 AX 6- 6 PCLI-A050CBE0 Clip 1 1 1 1 AD 6- 9 PSPAFA034CBE0 Sleeve 4 4 4 4 AD 6- 11 PPIPCA386CBEZ S.p connector 1 1 1 1 AF 6- 18 PPIPCA252CBE0 Charge pipe 2 2 2 2 AD 6- 19 FPIPCA172CBKZ Discharge p. ass’y 1 1 1 1 AM 6- 21 PCOVPA246CBE0 Terminal cover 1 1 1 1 AL 6- 24 PGUM-A004CBF0 Absorbent rubber a 2 2 2 2 AH 6- 25 QTAN-A045CBE0 Terminal block 1 1 1 1 AQ 6- 26 FPIPCA162CBKZ Eva pan pipe s ass’y 1 1 1 1 AS 6- 28 LANG-A058CBPZ Absorbent rubber clm 2 2 2 2 AC 6- 29 PGUM-A003CBF0 Absorbent rubber b 2 2 2 2 AH
MISCELLANEOUS
90- 1 TINS-A688CBRZ Operation manual 1 1 1 1 90- 2 TLAB-B042CBRZ Lamp label 1 1 1 1 AC 90- 3 SPAKCA184CBZZ Packing case 47n-f - - 1 1 90- 3 SPAKCA185CBZZ Packing case 43n-f 1 1 - ­ 90- 6 CPADBA799YDKZ Bottom pad ass’y 1 1 1 1 AV 90- 7 CPADBA057CBKZ Top pad ass’y 1 1 1 1 AR 90- 8 SPADBA190CBFZ Corner post fl 1 1 1 1 AK 90- 9 SPADBA191CBFZ Corner post fr 1 1 1 1 AL 90- 10 SPADBC435YDEZ Corner post bl 1 1 1 1 AG 90- 11 SPADBC436YDEZ Corner post br 1 1 1 1 AG 90- 15 TLAB-B055CBEZ R-door pocket label - - 1 1 AC 90- 21 TLAB-B009CBRZ Caution label rof 1 1 1 1 AE 90- 22 TLAB-A416CBR0 Warning label 1 1 1 1 AC 90- 24 TINS-A597CBRZ Caution sheet earth 1 1 1 1 90- 25 TINS-A366CBR0 Srv.station list 1 1 1 1 AC
30
SJ-P43N/43N SJ-P47N/47N
A
B
C
D
E
F
G
H
A
123456
123456
B
C
D
E
F
G
H
DOOR PARTS
SJ-P43N/43N SJ-P47N/47N
3-6
3-5
3-5-2
5-3
5-4
5-5
5-1
5-3
3-5-3 3-5-1
3-15-2
3-15-1
3-17
5-35
3-15
5-2
5-2
90-15
3-15-3
3-6
3-5
3-5-3 3-5-1
1-55
2-43
3-30
3-31
SJ-43N,47NSJ-P43N,P47N
3-5-4
3-5-5
3-8
3-10
3-11
3-9
3-20
3-7
3-7
3-19
3-21
3-22
31
SJ-P43N/43N SJ-P47N/47N
A
B
C
D
E
F
G
H
A
123456
123456
B
C
D
E
F
G
H
CABINET PARTS
2-49
2-49
2-91
2-7
2-7-2
2-7-1
2-8
2-8-2
2-7-1
2-14
5-31
5-17
5-6
5-32
5-9
5-24
1-10
2-15
5-13
4-3
5-25
2-32
5-16
2-93
2-93
2-93
2-93
5-18
5-19
2-36
2-36
5-15
5-24-1
5-24-2
5-25-2
5-25-1
5-25
5-24
SJ-43N,47N
SJ-P43N,P47N
2-29
2-13
SJ-P43N/43N SJ-P47N/47N
32
SJ-P43N/43N SJ-P47N/47N
A
B
C
D
E
F
G
H
A
123456
123456
B
C
D
E
F
G
H
CABINET PARTS
2-95
2-94
6-11
6-28
6-1
2-87
2-31
6-9
6-2
4-17
1-2
6-4
1-9
2-80
2-98
2-24
6-18
6-5
6-18
4-11 (4-12)
2-78
2-66
2-67
2-4
1-21
1-22
6-21
4-15
2-2
6-26
2-72
1-4
2-83 2-73
2-71
2-38
2-39
2-79
1-3
2-27
2-46
2-45
1-7
2-50
1-8
90-2
2-57
2-56
2-55
2-26
2-63
2-19
1-6
2-19
2-64
2-20
2-17
2-21
2-22
2-68
1-17
4-1
1-5
1-1
1-20
2-65
4-1
2-23
2-16
2-28
6-19
6-6
6-25
2-46
2-44
5-14
6-29
2-70
2-69
2-99
6-24
2-100
2-101
2-82
1-50
2-81
(Only for SJ-P43N,P47N)
(Only for SJ-P43N,P47N)
2-47
1-45
1-46
(Only for SJ-43N,47N)
1-32
1-23
1-34
1-33
1-11
2-77
SJ-P43N/43N SJ-P47N/47N
33
SJ-P43N/43N SJ-P47N/47N
34
SJ-P43N/43N SJ-P47N/47N
2005 SHARP CORP. (01K0.01E) Printed in Japan
43ATUF/ 43BTQF/ 47ATUF/ 47BTQF
COPYRIGHT © 2005 BY SHARP CORPORATION
ALL RIGHTS RESERVED.
No part of this publication may be repro­duced, stored in retrieval systems, or transmitted in any form or by any means, electronic, mechanical, photocopying, re­cording, or otherwise, without prior writ­ten permission of the publisher.
Loading...