Sharp SJ-43L-A2G,SJ-43L-A2A,SJ-43L-A2S,SJ-47L-A2G,SJ-47L-A2G-A2S,SJ-47L-A2G-A2A Service Manual

1
SJ-43L-A2 SJ-47L-A2
SERVICE MANUAL
S5219SE47JPS3
SHARP CORPORATION
TABLE OF CONTENTS
page
CAUTIONS AND INFORMATIONS ...................................................................................................................3
SPECIFICATIONS .............................................................................................................................................4
THE FICHE ........................................................................................................................................................5
DESIGNATION OF VARIOUS PARTS ..............................................................................................................6
DIMENSIONS ....................................................................................................................................................7
LIST OF ELECTRICAL PARTS .........................................................................................................................9
WIRING DIAGRAM..........................................................................................................................................10
FUNCTIONS ....................................................................................................................................................12
ASSEMBLING PROCEDURES OF MAIN PARTS AND CAUTIONS ..............................................................15
COOLING UNIT ...............................................................................................................................................21
REPLACEMENT PARTS LIST ........................................................................................................................23
Refrigerant; HFC-134a
Refer to "HFC-134a COOLING UNIT" Service Manual for handling this refrigerant.
DESTINATION .........................3
In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its original condition and only parts identical to those specified should be used.
REFRIGERATOR-FREEZER
MODELS
SJ-43L-
A2G/A2S/A2A
SJ-47L-
A2G/A2S/A2A
SJ-43L SJ-47L
This equipment complies with the requirements of Directives
96/57/EC, 89/336/EEC and 73/23/EEC as amended by 93/68/EEC.
2
SJ-43L-A2 SJ-47L-A2
INSTALLATION
Free standing type
To ensure adequate ventilation for this refrigerator, install with 6 cm space at the rear and both sides, with a minimum space of 9 cm above the refrigerator.
This refrigerator shall be used under the ordinary place condition between +5˚C and +38˚C of ambient temperature, and also not be left under -10˚C for long days. To be used this refrigerator within the range of the rated voltage+6%
Usage of "the ENERGY LABEL"
When displaying this refrigerator in the shop-window, attach the "ENERGY LABEL" to it in the following procedure.
"ENERGY LABEL (DATA)" (This label is in Operation manual)
"ENERGY LABEL (BASE)" of each language
Refrigerator
Data part
E
B
A
C
D
E
G
F
G
Fix the data part of "ENERGY LABEL (DATA)" on the data part of "ENERGY LABEL (BASE)"
6cm
6cm
9cm
ENERGY LABEL
3
SJ-43L-A2 SJ-47L-A2
Some household cleaning chemicals may affect the internal food liner and plastic parts resulting in splitting or cracks occurring. When cleaning all plastic parts inside this refrigerator, only use diluted dishwashing liquid(soapy water). Make sure that all plastic parts are thoroughly rinsed with water after cleaning.
CAUTIONS AND INFORMATIONS
1. Some foods freezed in the refrigerator compartment.
2. Some plastic parts were cracked or splitted.
Cracking or crunching sound;
Sound produced by expansion and contraction of inner walls and internal parts during cooling.
Squeaking sound;
Sound produced by expansion and contraction of internal parts.
Sound of flowing fluid (gurgling sound, fizzing sound);
Sound of refrigerant flowing in pipes (sound may become louder from time to time).
3. IT IS NORMAL for the refrigerator to produce the following sounds.
Do not place food directly in front of cold air outlet. This may lead to the food freezing.
IN OUT
cold air flow
In case of following troubles, the cause is not related with the failure of refrigerator. Please mention the correct way to the customer for the use of refrigerator when the repairing.
4
SJ-43L-A2 SJ-47L-A2
SPECIFICATIONS
Items SJ-43L-A2 SJ-47L-A2 Type 2-Door 2-Door Outer dimensions Height 1700mm(66.9") 1820mm(71.7") (Including spacer) Width 680mm(26.8") 680mm(26.8")
Depth 660mm(26.0") 660mm(26.0") Rated storage volume 347 liter (12.3cu.ft) 384 liter (13.6 cu.ft) (Rated volume) F: 99liter (3.5 cu.ft) F: 99 liter (3.5 cu.ft)
R: 248 liter(8.8 cu.ft) R: 285 liter(10.1 cu.ft)
Gross volume 370 liter (13.1cu.ft) 407 liter (14.4 cu.ft)
F: 107liter (3.8 cu.ft) F: 107 liter (3.8 cu.ft) R: 263 liter(9.3 cu.ft) R: 300 liter(10.6 cu.ft)
Defrosting System Heater system
Start Automatic
Finish Automatic Temperature control Automatic (Adjustable) No-frost freezer Yes Interior lamp 1 Caster 2 Evaporating pan 1 Refrigerator Refrigerator tray 2 Compartment Vegetable tray 1
Vegetable case 1
V parting plate 1
R door pocket 1
Egg tray 1
R door pocket S 2
Bottle pocket 1
Bottle stopper 1
Door pocket 1
Fresh case 1 Freezer Freezer tray 1 Compartment Ice cube maker Twin ice cube maker
Ice storage box 1
Door pocket 2 Deodorizing unit 2 ( Honeycomb type)
RATING
Items SJ-43L-A2 SJ-47L-A2 Rated voltage (V~) 220-240 Rated frequency (Hz) 50 Climate class ST Rated current (A) 1.2-1.3 Rated input (W) 115-120 Rated input of heating elements (W) 128-152 Refrigerant (Charging quantity) HFC-134a(105g) Net Weight (kg) 66 68
PLUG TYPE
Plug cord 3 Wires Plug type CS
Destination mark 3
COLOR
Items -A2G -A2S -A2A Outside color Gray Silver Beige Inside color White
Hole
5
SJ-43L-A2 SJ-47L-A2
DESIGNATION OF VARIOUS PARTS
Upper hinge cover
Hot pipe
Freezer temp. control knob
Hot pipe
Ventilating grille
Adjustable leg ass'y
Fan motor Defrost thermostat Evaporator Defrost heater
Damper thermostat Refrigerator temp. control knob
Drain pipe
Vegetable case
Compressor Starting relay, Overload relay(Protector)
Caster
Freezer compartment
Refrigerator compartment
Mark: Cold air flow
Evaporating pan
Defrost timer
Figure D-1. External Description
Figure D-2. Constructions
1
2 3 4
5
5
7 8
9
11
10
12 13
14 15
17
16
18 19
20
21
23 24
22
25 26
20
21
6
1. Freezer temp. control knob
2. Freezer shelf(Freezer tray)
3. Ice cube maker
4. Ice cube box(Ice storage box)
5. Deodorizing unit
6. Fresh case
7. Refrigerator temp. control knob
8. Light(Lamp)
9. Refrigerator shelf(Refrigerator tray)
10. Lever
11. Shelf(Vegetable tray)
12. Vegetable crisper(Vegetable case)
13. Separator plate(V parting plate)
14. Evaporating pan
15. Casters
16. Ventilating grille
17. Adjustable feet(Adjustable leg ass'y)
18. Fan switch
19. Fan & light switch
20. Utility pocket(Door pocket)
21. Magnetic door seal(Door packing)
22. Egg holder(Egg tray)
23. Egg pocket(R door pocket)
24. Small pocket(R door pocket S)
25. Bottle guard(Bottle stopper)
26. Bottle pocket
NOTE : 2 star section for storing
frozen food only. (not freezing)
The names are the denominations used in the REPLACEMENT PARTS LIST.
6
SJ-43L-A2 SJ-47L-A2
1
NO.
2 3 4 5 6
8
9
11 12 13 14
Trade mark
Items
Description
Remarks
Model name Type Energy efficiency class Eco-award mark Energy consumption
(220V 50Hz at 25 C)
Star rating of frozen food compartment
Temperature rise time Freezing capacity Climate class Noise
10 No frost
7
Net storage volume of frozen food storage compartment
SJ-43L
Category; 7
B
ST ST
39 dB(A) re 1 pw
39 dB(A) re 1 pw
510
kWh/year
708
kWh/year
744
kWh/year
248 L
No frost
9 h
6.0 kg /24h
Net storage volume of fresh food storage compartment
SJ-47L
Category; 7
B
560
kWh/year
285L
9 h
6.0 kg /24h
880/92 EN153
86/594/EEC
No frost
THE FICHE (according to ANNEX : 94/2/EC)
15
Maximum allowable electricity consumption (Emax)
(96/57/EC)
88 L
4-STAR
88 L
4-STAR
2-STAR
2-STAR
11 L
11 L
E max
(2.04)(1.94) (kWh/day)
fridge / freezer
A~G
7
SJ-43L-A2 SJ-47L-A2
DIMENSIONS
OUTER DIMENSIONS AND CLEARANCE
Fig. E-1(SJ-43L)
Fig. E-2(SJ-47L)
680
680
470
660
90
more than
60
more than
60
more than
60
more than
5951022.5
1700
73
16 9.5
1260
1320
1210
(Unit : mm)
1
1: Include the badge Not include the handle
90
more than
660
60
more than
680
5951142.5
1820
680
470
60
more than
60
more than
73
16
9.5
1260
1320
1210
(Unit : mm)
1
1: Include the badge Not include the handle
8
SJ-43L-A2 SJ-47L-A2
INNER DIMENSIONS
The dimensions between shelves can be changed by setting the shelves on the other rails.
Fig. E-3(SJ-43L)
Fig. E-4(SJ-47L)
(Unit: mm)
502
321
502
502
502
518
531
524
524
526
242
242
510
225
232
89
89
112
99
99
246
269
269
320
188
229
210
118
(218.5)
(175)
(185)
226
126
82
526
628.5
502
502
502
321
531
524
524
502
518
242
242
510
526
225
232
89
89
112
99
99
246
269
269
320
188
229
210
118
(168.5)
(125)
(165)
226
126
82
526
508.5
(Unit: mm)
9
SJ-43L-A2 SJ-47L-A2
LIST OF ELECTRICAL PARTS
ITEMS TYPE NAME RATING SPECIFICATIONS Thermostat MM1-8149 125V 6A (At normal notch)
250V 3A ON/OFF : -20 / -25˚C Defrost thermostat S101 250V 8A Open/Close : 8 / 1˚C Thermo. fuse SF70E 250V 10A Working temp. : 70˚C Fan motor 3R00121A 220-240V 50/60Hz Working with ø100 fan Defrost heater MM6-4264 220-240V 378 140W at 230V Door switch DSD-5 250V 0.25A 4 terminals push-button type Damper thermostat MM1-6173 Open/Close : 5 / 0˚C Defrost timer ND1004M2 220-240V Integration type
50/60Hz Cycle time : 10h44m/8h57m(50/60Hz)
Delay time : 4m20s/3m37s(50/60Hz) Lamp socket 250V 1A E-12(Hard plastic body type) Lamp 240V 15W E-12 Compressor FL1568SD 220-240V/50Hz Cooling capacity : 188W (50Hz)
Main coil : 13.3
Aux. coil : 25.6
(at 25˚C)
Starting relay PET0SAT 22 300V Overload relay(Protector) 1.8C36A1 Open/ Close : 130/60˚C Running capatior 420V or 450V 4µF—
Common
Main coil
Aux. coil
10
SJ-43L-A2 SJ-47L-A2
WIRING DIAGRAM
Be sure to replace the electrical parts with specified ones for maintaining the safety and performance of the set.
E
CONNECTED IN TERMINAL BOX CONNECTOR
GY BR OR Y R P BL BK SB G-Y W
: GRAY : BROWN (live) : ORANGE : YELLOW : RED : PINK : BLUE(neutral) : BLACK : SKY-BLUE : GREEN-YELLOW (earth) : WHITE
F-Thermostat
(R)
Defrost timer
TM
Thermo. fuse
FM
Defrost heater
Defrost thermo.
Starting relay
C
M
A
Compressor
Protector
(BL)
Door switch
Source Plug
(SB)
Fan motor
L
(OR)
(BR)
(W)
(Y)
(GY)
(BK)
Lamp
Running capacitor
Figure W-1. Wiring Diagram
Loading...
+ 22 hidden pages