COPIER : SF-2218
1.MEASURE TO ALLEVIATE PROBLEMS OF CONTACT WITH THE TC CASE UNIT.
2.CHANGE IN THE MAKER OF THE POWER TRANSFORMER CARRIED OUT AS A
MEASURE TO IMPROVE PRODUCTIVITY.
No. : S-265
1. Measure to alleviate problems of contact with the TC case unit.
1.Model Name: SF-2218 (Only for machines bound for China)
2.General: There was a problem of contact between the TC case unit and the TC positioning angle
when the machine was opened and closed. As a measure to alleviate this problem a
change has been carried out in the shape of the TC paper guide.
3.Description:
Cut
4.*Action: Japanese domestic production: From 1998 September production.
2 square holes
Chinese (SOCC) production: From 1998 September production.
French (SMF) production: From 1998 October production.
2. Change in the maker of the power transformer carried out as a measure to improve
productivity.
1.Model Name: SF-2218 (Only for machines bound for China)
2.General: A change has been carried out in the maker of the power transformer. This action has
3.Action: From the 1st lot of 1998 October production.
been carried out as a measure to improve productivity.
SHARP CORPORATION Reprography Division
1/2
Green
C
Ref.
No.
Model
name
Version P/G No.
Current parts New parts
Parts code Parts code
Price
rank
Parts name
Effec-
tive
time
Inter-
change-
ability
Note
1
SF-2218 China
2 20 -16 RTRNP0540FCZZ RTRNP0503FCZZ BG
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
Parts marked with " " is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
26 -12 PGIDH1546FCZZ PGIDH1546FCZ1 AG TC Paper Guide * 3
Power
Transformer
5. Interchangeable if replaced with same types of
related parts in use.
6. Others.
1st lot
'98/10
1
2/2