COPIER : SF-2025
No. : S-260
CA KEY'S MARGIN OF MOVEMENT INCREASED.
1.Model Name: SF-2025/2030/2040
2.General: When you press the CA key located in the operation panel, there is often no clicking
sensation, or a very weak one. This is the result of the CA key coming in contact with
the key sheet. The instructions below explain how to correct this problem. It should be
noted that his problem does not effect the unit's functioning, however.
3.Description: Position the attachment bases for the key sheet as illustrated below. This creates a
margin between the CA key and the key sheet, preventing them from touching.
(Attachment standard)*
* Operation filter Line up standard A with a, and standard F with f.
* Key sheet A Line up standard A with a, and standard B with b.
* Key sheet B Line up standard C with c, and standard D with d.
* Key sheet C Line up standard A with a, and standard E with e
Operation filter
Key sheet A
Key
sheet C
Key sheet B
Key sheet C
Operation
filter
Key
sheet B
Key
sheet A
If a unit whose CA key has no clicking sensation is returned, please replace key sheet A.
SHARP CORPORATION Reprography Division