SHARP DTE275 Technical Report

COPIER(OPTION) : SF-S55
Date
:
May. 27, 1997
No. : DTE-275
MEASURE TO ALLEVIATE PROBLEMS OF JAMS CAUSED BY OPERATION MISSES OF THE INTERFACE ROD.
1.Model Name: SF-S55
2.General: The changes in software described below have been carried out to alleviate problems of
operation misses of the interface rod in the models listed above.
3.Description: A change has been carried out so that the interface operation can be carried out with the
second load operation after the first multi-load extraction is carried out.
P-ROM Ver. No. 7.20 8.10
4.Action: From the start of 1996 November production.
Ref.
Model
name
Version P/G No.
New type cannot be used in place of current type.
New type can be used in place of current type.
2 -19
14 -901
14 ---- OGZ4F10296080 BD P-ROM [Q4] 6
No.
SF-S55 All
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type.
3. Current type cannot be used in place of new type.
Parts marked with " " is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Current parts New parts
Parts code Parts code
OGZ4G10191000 OGZ4G10191030 CK Main control PWB
Price
rank
5. Interchangeable if replaced with same types of related parts in use.
6. Others.
Parts name
Effec-
tive
time
1st lot '96/11
Inter-
change-
ability
3
Note
SHARP CORPORATION Reprography Division
Green
C
Loading...