SHARP DTE259 Technical Report

Date: Feb. 26, 1997
DUPLICATOR : SD-4085
1.CHANGE IN THE PROTECTIVE MYLAR SHEETS OF THE AC PWB CARRIED OUT AS A MEASURE TO IMPROVE PRODUCTIVITY.
2.CHANGES CARRIED OUT AS A MEASURE TO IMPROVE COPY PERFORMANCE.
3.CHANGE IN THE PTL FILTER CARRIED OUT AS A MEASURE TO IMPROVE PRODUCTIVITY.
No. : DTE-259
1. Change in the protective mylar sheets of the AC PWB carried out as a measure to improve productivity.
1.Model Name: SD-4085
the AC PWB in the model listed above. The thickness of the mylar sheets has been changed from 0.25 to 0.188. This change has been carried out as a measure to improve productivity.
3.Description: (Old) PSHEP4343FCZZ PSHEP4344FCZZ ↓ ↓
(New) PSHEP4343FCZ1 PSHEP4344FCZ1
4.Action: From 1996 November production.
2. Changes carried out as a measure to improve copy performance.
1.Model Name: SD-4085
2.General: (1) Problems of white-outs have occurred in the rear edges of thick copy paper. As a
measure to alleviate this problem, a change has been carried out in the AC guide. As a result of this change the adhesion of the rear edge of the copy paper to the drum has been improved.
(2) Problems of pitch unevenness in 52 g/m copy paper have occurred. As a measure
2
to alleviate these problems, A TC ion electrode has been added. As a result of this change problems of black streaking have been alleviated. A change has also been carried out in the separator DC bias.
SHARP CORPORATION Reprography Division
1/3
Green
C
3.Description: (1) No. 2 and No. 3 case units
<Discontinued> AC Guide PGIDH1211FCZ2 <Added> AC Guide E PGIDM1757FCZZ
TC ion electrode PSHEZ4342FCZZ
TC ion Electrode attachment positioning should be carried out with the proper tool.
TC ion electrode PSHEZ4342FCZZ
TC ion electrode
(2) A change has been carried out in the separator DC bias voltage.
+300 V → +74 V (The change has been carried out by simulation 8-7)
4.Action: From 1996 mid-October production.
No. 2 and No. 3 C-Case unit As CCASZ0279FC01
2/3