SHARP DTE258 Technical Report

Date: Feb. 27, 1997
DUPLICATOR : SD-4085
1. CHANGE IN THE GROUND SCREWS CARRIED OUT AS A MEASURE TO IMPROVE OPERATIONABILITY.
2. CHANGE IN THE SHAPE OF PARTS CARRIED OUT AS A MEASURE TO COMPLY WITH EUROPEAN STANDARDS.
3. ESTABLISHMENT OF INTERCHANGEABILITY FOR THE MAIN PWB CARRIED OUT AS A MEASURE TO IMPROVE OPERATIONABILITY.
4. MEASURE TO PREVENT DAMAGE TO THE MC DUCT MOLT.
No. : DTE-258
1. Change in the ground screws carried out as a measure to improve operationability.
1.Model Name: SD-4085
attachment plate unit in the model listed above. Ground screw (XBPBZ40P06000) has been changed to ground screw (XBPBZ40P06K00, with a washer). This change has been carried out as a measure to improve operationability .
3.Action: From 1996 November production.
2. Change in the shape of parts carried out as a measure to comply with European standards.
1.Model Name: SD-4085
2.General: In order to comply with European standards it was necessary to add two more heater
lamps in the model listed above. In order to carry out this change the hole in the fusing frames F and R through which the heater lamps are inserted has been enlarged.
3.Description: Old CFRM-0630FC01 CFRM-0884FC01
New CFRM-0630FC02 CFRM-0884FC02
CFRM-0884FC02
Fusing frame F CFRM-0630FC02
Hole ø20 ø25
Hole ø20 ø25
4.Action: From 1996 November production. (From the start of production for the 200 V line
markets.)
Green
SHARP CORPORATION Reprography Division
1/3
C
3. Establishment of interchangeability for the main PWB carried out as a measure to improve operationability.
1.Model Name: SD-4085
2.General: Interchangeability of the main PWB with the 200 V line markets has been established
as a measure to improve adjustment operationability in the production lines.
3.Description: Differences between the 100 V and 200 V lines. (1)Chip R390 VRS-TS2AD391J- Q’ty: 1 → 3 (2)Chip R4.7K VRS-TS2AD472J- Q’ty: 36 37 (3)Chip R5.6K VRS-TS2AD562J- Q’ty: 8 → 9 (4) DAP 202K VHDDAP202K/-1- Q’ty: 11 13 (5) SLR 322VC VHPSLR322VC3FT Q’ty: 0 → 2
4.Action: From 1996 October production. (From the start of production for the 200 V line markets.)
4. Measure to prevent damage to the MC duct molt.
1.Model Name: SD-4085
2.General: A PET has been added to the MC duct molt in the model listed above as a measure to
prevent damage to the molt when the MC duct attachment plate unit slides.
3.Description: Old PMLT-1047FCZZ
New PMLT-1047FCZ1
Changed
MC duct molt B
MC duct molt B
MC duct molt B
MC duct molt B (PMLT-1047FCZZ)
(PMLT-1047FCZZ)
(PMLT-1047FCZZ)
(PMLT-1047FCZZ)
PMLT-1047FCZZ
Added PET
PMLT-1047FCZ1
4.Action: From 1996 mid-September production.
2/3
Ref.
No.
Model
name
Version P/G No.
Current parts New parts
Parts code Parts code
Price
rank
Parts name
Effec-
tive
time
Inter-
change-
ability
Note
1
2
SD-4085
3
4 All
<Inter c h an g e>
1. Interchangeable. 4. Not interchangeable.
2. C urr e nt t y pe c a n be u s ed i n place of n ew t y pe . New ty pe cann ot be us ed in place of curr ent type .
3. C urr e nt t y pe c a nn ot b e us e d in p l ace o f ne w ty p e. New t y pe c a n be u sed in pl a ce of curr en t ty p e.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
SEC SECL
38 -B14
All
24 -165 CFRM-0630FC01 CFRM-0630FC02 BB Fusing frame F
24 -81 CFRM-0884FC01 CFRM-0884FC02 BF Fusing frame R
72 -901 CPWBN1168FC51 CPWBN1168FC52 CN Main PWB
14 -3
!
XBPBZ40P06000 XBPBZ40P06K00 AA Ground screws
PMLT-1047FCZZ PMLT-1047FCZ1 AG MC duct molt B
5. Interchangeable if replaced with same types of relate d parts in use .
6. Others.
1st lot ’96/11
1st lot ’96/10
Mid-
’96/9
1
3
1
3
3/3