Date : |
Feb. 27, 1997 |
|
DUPLICATOR : SD-4085 |
No. : |
DTE-258 |
|
|
|
1. |
CHANGE IN THE GROUND SCREWS CARRIED OUT AS A MEASURE TO IMPROVE OPERATIONABILITY. |
|
|
|
2. |
CHANGE IN THE SHAPE OF PARTS CARRIED OUT AS A MEASURE TO COMPLY WITH EUROPEAN |
|
|
|
|
STANDARDS. |
|
|
|
3. |
ESTABLISHMENT OF INTERCHANGEABILITY FOR THE MAIN PWB CARRIED OUT AS A MEASURE TO |
|
|
|
|
IMPROVE OPERATIONABILITY. |
|
|
|
4. |
MEASURE TO PREVENT DAMAGE TO THE MC DUCT MOLT. |
|
|
|
|
|
|
|
|
|||
|
1. Change in the ground screws carried out as a measure to improve operationability. |
|||
1.Model Name: |
|
|
|
|
SD-4085 |
|
|
||
2.General: |
A change has been carried out in the screws which retain the ground in the AC |
|||
|
attachment plate unit in the model listed above. Ground screw (XBPBZ40P06000) has |
|||
|
been changed to ground screw (XBPBZ40P06K00, with a washer). This change has |
|||
|
been carried out as a measure to improve operationability. |
|||
3.Action: |
From 1996 November production. |
2.Change in the shape of parts carried out as a measure to comply with European standards.
1.Model Name: |
SD-4085 |
|
|
2.General: |
In order to comply with European standards it was necessary to add two more heater |
||
|
lamps in the model listed above. In order to carry out this change the hole in the fusing |
||
|
frames F and R through which the heater lamps are inserted has been enlarged. |
||
3.Description: |
Old |
CFRM-0630FC01 |
CFRM-0884FC01 |
|
|
↓ |
↓ |
|
New |
CFRM-0630FC02 |
CFRM-0884FC02 |
|
|
CFRM-0884FC02 |
Fusing frame F |
|
|
|
CFRM-0630FC02 |
|
|
|
Hole ø20 → ø25 |
|
Hole ø20 → ø25 |
|
|
4.Action: |
From 1996 November production. (From the start of production for the 200 V line |
||
|
markets.) |
|
1/3
SHARP CORPORATION |
Reprography Division |
Green
C
3.Establishment of interchangeability for the main PWB carried out as a measure to improve operationability.
1.Model Name: |
SD-4085 |
2.General: Interchangeability of the main PWB with the 200 V line markets has been established as a measure to improve adjustment operationability in the production lines.
3.Description: |
Differences between the 100 V and 200 V lines. |
||
|
(1) Chip R390 |
VRS-TS2AD391J- |
Q'ty: 1 → 3 |
|
(2) Chip R4.7K |
VRS-TS2AD472J- |
Q'ty: 36 → 37 |
|
(3) Chip R5.6K |
VRS-TS2AD562J- |
Q'ty: 8 → 9 |
|
(4) DAP 202K |
VHDDAP202K/-1- |
Q'ty: 11 → 13 |
|
(5) SLR 322VC |
VHPSLR322VC3FT |
Q'ty: 0 → 2 |
4.Action: From 1996 October production. (From the start of production for the 200 V line markets.)
|
4. Measure to prevent damage to the MC duct molt. |
|
||
1.Model Name: |
SD-4085 |
|
|
|
2.General: |
A PET has been added to the MC duct molt in the model listed above as a measure to |
|||
|
prevent damage to the molt when the MC duct attachment plate unit slides. |
|||
3.Description: |
Old |
PMLT-1047FCZZ |
|
|
|
|
↓ |
|
|
|
New |
PMLT-1047FCZ1 |
|
|
|
|
|
|
Changed |
|
|
MC duct molt B |
|
Added PET |
|
|
PMLT-1047FCZZ |
||
|
|
(PMLT-1047FCZZ) |
||
|
|
|
PMLT-1047FCZ1 |
|
|
|
|
|
|
4.Action: |
From 1996 mid-September production. |
|
|
2/3