Date: Feb. 27, 1997
DUPLICATOR : SD-4085
1. CHANGE IN THE GROUND SCREWS CARRIED OUT AS A MEASURE TO IMPROVE OPERATIONABILITY.
2. CHANGE IN THE SHAPE OF PARTS CARRIED OUT AS A MEASURE TO COMPLY WITH EUROPEAN
STANDARDS.
3. ESTABLISHMENT OF INTERCHANGEABILITY FOR THE MAIN PWB CARRIED OUT AS A MEASURE TO
IMPROVE OPERATIONABILITY.
4. MEASURE TO PREVENT DAMAGE TO THE MC DUCT MOLT.
No. : DTE-258
1. Change in the ground screws carried out as a measure to improve operationability.
1.Model Name: SD-4085
2.General: A change has been carried out in the screws which retain the ground in the AC
attachment plate unit in the model listed above. Ground screw (XBPBZ40P06000) has
been changed to ground screw (XBPBZ40P06K00, with a washer). This change has
been carried out as a measure to improve operationability .
3.Action: From 1996 November production.
2. Change in the shape of parts carried out as a measure to comply with European
standards.
1.Model Name: SD-4085
2.General: In order to comply with European standards it was necessary to add two more heater
lamps in the model listed above. In order to carry out this change the hole in the fusing
frames F and R through which the heater lamps are inserted has been enlarged.
3.Description: Old CFRM-0630FC01 CFRM-0884FC01
↓ ↓
New CFRM-0630FC02 CFRM-0884FC02
CFRM-0884FC02
Fusing frame F
CFRM-0630FC02
Hole ø20 → ø25
Hole ø20 → ø25
4.Action: From 1996 November production. (From the start of production for the 200 V line
markets.)
Green
SHARP CORPORATION Reprography Division
1/3
C
3. Establishment of interchangeability for the main PWB carried out as a measure to
improve operationability.
1.Model Name: SD-4085
2.General: Interchangeability of the main PWB with the 200 V line markets has been established
as a measure to improve adjustment operationability in the production lines.
3.Description: Differences between the 100 V and 200 V lines.
(1)Chip R390 VRS-TS2AD391J- Q’ty: 1 → 3
(2)Chip R4.7K VRS-TS2AD472J- Q’ty: 36 → 37
(3)Chip R5.6K VRS-TS2AD562J- Q’ty: 8 → 9
(4) DAP 202K VHDDAP202K/-1- Q’ty: 11 → 13
(5) SLR 322VC VHPSLR322VC3FT Q’ty: 0 → 2
4.Action: From 1996 October production. (From the start of production for the 200 V line markets.)
4. Measure to prevent damage to the MC duct molt.
1.Model Name: SD-4085
2.General: A PET has been added to the MC duct molt in the model listed above as a measure to
prevent damage to the molt when the MC duct attachment plate unit slides.
3.Description: Old PMLT-1047FCZZ
↓
New PMLT-1047FCZ1
Changed
MC duct molt B
MC duct molt B
MC duct molt B
MC duct molt B
(PMLT-1047FCZZ)
(PMLT-1047FCZZ)
(PMLT-1047FCZZ)
(PMLT-1047FCZZ)
PMLT-1047FCZZ
Added PET
PMLT-1047FCZ1
4.Action: From 1996 mid-September production.