SHARP DTE257 Technical Report

Date: Jan. 10, 1997
DUPLICATOR : SD-4085/2075
1. CHANGE IN THE SHAPE OF THE PU SUPPORT PLATE F/R AS A MEASURE TO IMPROVE OPERATIONABILITY.
2. CHANGE IN SPECIFICATIONS.
3. MEASURE TO PREVENT CONTACT WITH THE SWITCH LEVER.
4. MEASURE TO IMPROVE THE INPUT POWER SUPPLY OF THE CLR PWB.
No. : DTE-257
1. Change in the shape of the PU support plate F/R as a measure to improve operationability.
1.Model Name: SD-4085
the RDH pop up unit F/R to the rear tip paper guide unit. This method of securing the RDH pop up unit F/R resulted in extremely poor operationabilty performance, however, and as an improvement measure the use of the washer has been discontinued, and a change in the shape of the PU support plate has been carried out to replace it.
3.Action: From the start of 1996 November production.
2. Change in specifications.
1.Model Name: SD-4085
2.General: Changes have been carried out in the content of the main ROM in the main PWB, the
program ROM in the operation control PWB, the operation manual and the key operator guide. These changes were carried out in accordance with a change that was carried out in the specifications.
3.Description: Content of the change that was carried out in the specifications: Key operator manual, P24. The number of fixed magnifications which can be set has
°
been established at one (1), and moreover, in simulation 26-28 the addition of three (3) fixed magnifications has been made possible. The range of change for the magnification of the zoom key has been established so
°
that it is within the fixed magnification. (Continual depression of the zoom key will continue to change the magnification, but the magnification will stop at each fixed magnification. The zoom key must be turned off once and turned back on to change the magnification to the selected fixed magnification.)
SHARP CORPORATION Reprography Division
1/4
Green
C
The ready lamp will be turned ON even for EXTRA sized paper during the double side
°
copy mode. When copy operations are started, the S-D mode will be changed to the S-S mode, and the D-D mode will be change to the D-S mode before copying.
The interchangeability of the main ROM in the main PWB, the program ROM in the operation PWB and the data ROM are as shown in the table below.
Main ROM up to V3.06 Main ROM versions later than 4.00 Program ROM up to V3.01 Data (English) ROM up to V3.02 Program ROM versions later than 4.00 Data (English) ROM versions later than 4.00
O: interchangeable X: not interchangeable
Please refer to the parts list for information concerning.
4.Action: From 1996 mid-September production.
3. Measure to prevent contact with the switch lever.
1.Model Name: SD-4085
2.General: The switch lever inside the RDH transport frame unit was too close to the sensor,
creating the danger of contact. As a trouble shooting measure to alleviate this problem, a change has been carried out in the E-ring groove of the lift up shaft and the position of the pin hole, preventing contact from taking place.
Sensor
Sensor
Switch lever position moved 1 mm.
Lift up shaft
Lower limit switch lever
3.Action: From the start of 1996 September production.
2/4
Lift up shaft
Lower limit switch lever
Loading...