SHARP DTE236 Technical Report

Date: Oct. 22, 1996
COPIER : SD-4085
No. : DTE-236
REGARDING THE CCFT SERVICE PART.
1.Model Name: SD-4085
2.General: In order to improve serviceability, we have established the CCFT inside the operation
panel unit as a service part.
3.Description: For instructions on changing the CCFT, see the appended sheet.
4.Action: From the first unit of September, 1996 production on.
SHARP CORPORATION Reprography Division
1/3
C
(Procedures for changing the CCFT unit)
LCD UN (VVLLM32P07/-1)
LCD shield sheet (PSHEP4196FCZZ)
1. Peel off the shield sheet attached to the LCD UN. Note: The shield sheet cannot be reused, so dispose of it after peeling it off.
Screw
BL holder
CCFT unit (RLMPU0608FCZZ)
Plastic chassis
Transparent board
LCD panel
Bezel
2. Remove the screw fastening the CL holder as indicated in Fig. 2.
3. Remove the BL holder.
4. Replace the CCFT unit.
5. Insert the BL holder between the bezel and the transparent board.
6. Hook the three tabs onto the plastic chassis.
7. Fasten it with the screws.
2/3
Attachment position
LCD shield sheet (PSHEP4196FCZZ)
LCD UN (VVLLM32P07/-1)
8. Attach the new LCD shield sheet to the LCD UN at the position shown in fig. 3. Clean the attachment area before attaching the sheet.
Ref.
Model
No.
SD-4085 All
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. C urr e nt t y pe c a n be u s ed i n p la ce of new ty pe . New ty pe cann ot be us ed i n place of curr ent type .
3. C urre nt ty pe cann ot be used i n place of new ty pe. New t y pe c a n be u sed in p la ce of curr en t ty p e.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
name
Version P/G No.
1
!
Current parts New parts
Parts code Parts code
RLMPU0608FCZZ BA CCFT unit
Price
rank
5. Interchangeable if replaced with same types of relate d parts in use .
6. Others.
Parts name
Effec-
tive
time
1st lot
’96/9
Inter-
change-
ability
6
Note
3/3