Date: Nov. 30, 1995
DUPLICATOR : SD-2060
1. MEASURE TO IMPROVE THE FUSE BURN-OUT MARGIN OF THE
FUSES IN THE POWER SUPPLY PWB.
2. MEASURE TO PREVENT CONTACT WITH THE PWB ELEMENTS
3. MEASURE TO PREVENT CRACKING OF THE ADIABATIC
BUSHING OF THE FUSING UNIT.
4. CHANGE IN BEARINGS TO IMPROVE PRODUCTIVITY.
No. : DTE-218
1. Measure to improve the fuse burn-out margin of the fuses in the power supply PWB.
1.Model name: SD-2060/3062 (only for machines in the 100 V series).
2.General: To improve the DC power supply PWB fuse burn-out margin in machines bound for the
Japanese domestic market, a change in fuses F710 and F703 was carried out. The
change that was carried out in machines bound for the Japanese domestic market also
complied with standards in the overseas markets, and as a result, the change has also
been carried out on fuses in machines bound for overseas markets.
In accordance with the change described above, the parts code for the DC power
supply PWB has also been changed.
3.Description: F710: 3.15 A/125 V → 4.0 A/125 V .
F703: 4.0 A/125V → 5.0 A/125 V.
Note: The 5.0 A/125 V fuses used after the change described above has been carried
out is a newly established part, but the 4.0 A/125 V fuses previously used with fuse
F703 can be transferred for use with fuse F710.
4.Action: SD-2060 → From 1995 mid-July production.
SD-3062 → From 1995 mid-August production.
SHARP CORPORATION Reprography Division
1/3
Green
C

2. Measure to prevent contact with the PWB elements.
1.Model name: SD-3062
2.General: When installing the photo transistor in the paper detection sensor attachment plate
used in the finisher frame unit and the finisher gate frame unit, there is a possibility of
the photo transistor PWB elements coming in contact with the paper detection sensor
attachment plate. To alleviate this problem, the shape of the paper detection sensor
attachment plate has been changed.
3.Action: From the start of 1995 September production.
3. Measure to prevent cracking of the adiabatic bushing of the fusing unit.
1.Model name: SD-2060/3062
2.General: Cracking sometimes occurs in the adiabatic bushing used in the upper heat roller of the
fusing unit. To alleviate this problem, a change in the material of the bushing has been
carried out to strengthen it.
3.Action: From the start of 1995 December production.
4. Change in bearings to improve productivity.
1.Model name: SD-2060/3062
2.General: A change in the bearings used in the air paper feeding unit has been carried out to
improve productivity.
3.Action: From the start of 1995 December production.
2/3

Ref.
Model
No.
SD-2060
SD-3062
SD-2060
SD-3062
1
SD-2060
SD-3062
2
3
SD-2060
SD-3062
4
<Interchange>
1. Interc ha ng ea bl e. 4. N ot i nt er ch an ge ab l e.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with
specified on es fo r m ain taining t he s a fe ty and pe r fo r ma nce o f th e s et .
name
Version P/G No.
85 -128
100V
series
8-1
85 -901
8-1
85 -901
50 -30 LPLTM4476FCZZ LPLTM4476FCZ1 AH
52 -34 LPLTM4475FCZZ LPLTM4475FCZ1 AG
All
12 -113 LBSHZ0178FCZ1 LBSHC0334FCZZ AT Busing
18 -6
19 -6
!
Current parts New parts
Parts code Parts code
0CBPJCJS3151/ 0CBPJCJS4001/ AF Fuse [F710]
0CBPJCJS4001/ 0CBPJCJS5001/ AE Fuse [F703]
CPWBN0999FC32 CPWBN0999FC34 CF
CPWBN0999FC31 CPWBN0999FC33 CG
NBRGY0475FCZZ NBRGY0558FCZZ AF Bearing 1 Q’ty: 4
Price
5. Interchangeable if replaced with same types of
relate d parts in use .
6. Others .
Parts name
rank
DC power
supply PWB
Paper detect
sensor fixing
plate
Effec-
tive
time
Mid-
’95/7
Mid-
’95/8
Mid-
’95/7
Mid-
’95/8
1st lot
’95/9
1st lot
’95/12
Inter-
change-
ability
3
Note
Q’ty: 2
3/3