Date: Feb. 3, 1995
DUPLICATOR: SD-2060
1. PREVENTION OF DETACHING OF MANUAL SPACER INSIDE MANUAL FEEDING UNIT
2. CHANGE OF PROCESSING METHOD COPY STOPPER (TO IMPROVE PRODUCTION)
3. ADDITION OF MYLAR TO OPERATION BASE PLATE
4. PREVENTION OF PAPER GUIDE CONTACT EARTH SCREW IN FIXING UNIT
No. : DTE-199
1. Prevention of detaching of manual spacer inside manual feeding unit
1.Model name: SD-2060, 3062
2.General: We attached the manual feeding spacer to the tray cover with a double sided tape and
adhesives. However, the spacer was possibly detached from the cover during
transporting it. Moreover, it worsened the efficiency of assembling.
3.Description: We have changed the way to attach the spacer, from using the double-sided tape and
the adhesives to attaching the manual feed spacer sheet on the spacer.
Manual feeding spacer sheet
Center
Manual feeding spacer
Tray cover
Center
Attach it at the center standard.
Clean the attaching surface with alcohol.
Manual feeding spacer sheet
Manual feeding spacer
4.Action: From mid-November 1994 production (running change)
2. Change of finishing method of copy stopper (to improve production)
1.Model name: SD-2060
2.General: We have changed the finishing method of the copy stopper to improve productivity.
Green
C
SHARP CORPORATION Reprography Division
1/3
3.Description: Change the finishing method
(Current) (New)
Spraying clear lacquer → Epoxy polyester resin
Parts code have been changed. Parts are compatibly used between the current one
and the new.
4.Action: From the first unit of November 1994 production
3. Addition of mylar to operation base plate
1.Model name: SD-2060, 3062
2.General: We informed to use the operation base plate interchangeably with the one for the model
SD-2160 in the Technical Report DTE-198. However, when the plate for SD-2160 was
used to the model SD-2060 and 3062, it was impossible to insert a user’s finger to the
plate and also needed to
cover a notch. Therefore
we have added mylars to
Standard
Standard
that.
Attach the mylar after you
clean the shaded part
Standard
shown in the right
illustration.
Mylar for door switch Standard
3.Action: From the first unit of November 1994 production
4. Prevention of paper guide contact earth screw in fixing unit
1.Model name: SD-2060, 3062
2.General: The M4X6 ground screw used in the rear side
frame in the fixing unit contacted the paper guide
on rare occasion. Therefore we have changed
screws to the M4X5 ground screw to prevent it.
These ground screws’ descriptions were missed in
the parts’ guide. Please add them to the parts’
guide.
Attach it from the R end.
Do not cover the r.
Do not mylar to be unstable.
Cover the shaded part.
2/3
Ground screw