Date: Jun. 10, 1994
COPIER : SF-8570
No. : CCT-085
CHANGE TO RELAY AS TERMINATION OF
PRODUCTION HAS BEEN CARRIED OUT
1.Model name: CX-7700
2.General: Change the Relay (G5R5-A) used in Models above to s ubstit utional products because
termination of production has been carried out.
Before change has been carried out, same type of the relay was used in both 100V
series and 200V series. To meet safety standard specifications, relays newly have been
laid each 100V series and 200V series.
3.Description: Current (100V/200V) New (100V)
G2R-1A RRLY D4121QCZZ
G5R5-A RRLYD3121QCZZ (200V)
G2R-1A4-SKVD RRLY D3128QCZZ
4.Action: From April 1994 production.
Ref.
Model
No.
1 CX-7700
<Interchange>
1. Interc ha ng ea bl e. 4. Not int erc h an ge ab l e.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with
speci fied on es fo r m ai n ta ini ng t he safe ty an d pe r fo rma nc e o f th e set.
name
Version P/G No.
100V
series
37 -5 RRLYD3121QCZZ
200V
series
!
Current parts New parts
Parts code Parts code
RRLYD4121QCZZ AN
RRLYD3128QCZZ AQ
5. Interchangeable if replaced with same types of
6. Others .
Price
relate d parts in use .
Parts name
rank
Relay
Effec-
tive
time
See
text.
Inter-
change-
ability
1
Note
SHARP CORPORATION Reprography Division
Green
C