Attention: Your product is
marked with this symbol. It
means that used electrical
and electronic products
should not be mixed with
general household waste.
There is a separate
collection system for these
products.
A. Information on Disposal for Users (private households)
1. In the European Union
Attention: If you want to dispose of this equipment, please do not use the ordinary dust
bin!
Used electrical and electronic equipment must be treated separately and in
accordance with legislation that requires proper treatment, recovery and recycling of
used electrical and electronic equipment.
Following the implementation by member states, private households within the EU
states may return their used electrical and electronic equipment to designated
collection facilities free of charge*. In some countries* your local retailer may also
take back your old product free of charge if you purchase a similar new one.
*) Please contact your local authority for further details.
If your used electrical or electronic equipment has batteries or accumulators, please
dispose of these separately beforehand according to local requirements.
By disposing of this product correctly you will help ensure that the waste undergoes
the necessary treatment, recovery and recycling and thus prevent potential negative
effects on the environment and human health which could otherwise arise due to
inappropriate waste handling.
2. In other Countries outside the EU
If you wish to discard this product, please contact your local authorities and ask for the
correct method of disposal.
For Switzerland: Used electrical or electronic equipment can be returned free of
charge to the dealer, even if you don’t purchase a new product. Further collection
facilities are listed on the homepage of
. Information on Disposal for Business Users.
B
www.swico.chor www.sens.ch.
1. In the European Union
If the product is used for business purposes and you want to discard it:
Please contact your SHARP dealer who will inform you about the take-back of the
product. You might be charged for the costs arising from take-back and recycling.
Small products (and small amounts) might be taken back by your local collection
facilities.
For Spain: Please contact the established collection system or your local authority for
take-back of your used products.
2. In other Countries outside the EU
If you wish to discard of this product, please contact your local authorities and ask for
the correct method of disposal.
EN
ENGLISH
Thank you for purchasing a SHARP air conditioner. Please read this manual carefully
before operating the product.
CONTENTS
• IMPORTANT SAFEY INSTRUCTIONS .... E-1
• ADDITIONAL NOTES ON OPERATION .. E-3
• TIPS ON SAVING ENERGY..................... E-3
• PART NAMES........................................... E-4
• BEFORE CALLING FOR SERVICE .................E-16
IMPORTANT SAFETY INSTRUCTIONS
WARNINGS FOR USE
Do not pull or deform the power supply cord. Pulling and misuse of the power supply cord
1
can result in damage to the unit and cause electrical shock.
Be careful not to expose your body directly to the outlet air for a long time. It may affect
2
your physical conditions.
When using the air conditioner for infants, children, elderly, bedridden, or disabled people
3
make sure the room temperature is suitable for those in the room.
Never insert objects into the unit. Inserting objects can result in injury due to the high
4
speed rotation of internal fans.
ENGLISH
Ground the air conditioner without fail. Do not connect the grounding wire to gas pipe,
5
water pipe, lightning rod or telephone grounding wire. Incomplete grounding may cause
electric shock.
If anything is abnormal with the air conditioner (ex. a burning smell), stop the operation
6
immediately and turn the circuit breaker OFF.
The appliance shall be installed in accordance with national wiring regulations. Improper
7
cable connection can cause the power supply cord, plug and the electrical outlet to
overheat and cause fire.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
8
or a similarly qualified person in order to avoid a hazard. Use only the manufacturespecified power cord for replacement.
WARNINGS FOR INSTALLATION / REMOVAL / REPAIR
• Do not attempt to install/remove/repair the unit by yourself. Incorrect work will cause electric
shock, water leak, fire etc. Consult your dealer or other qualified service personnel for the
installation/removal/repair of the unit.
E-1
IMPORTANT SAFETY INSTRUCTIONS
CAUTIONS FOR USE
Open a window or door periodically to ventilate the room, especially when using gas
1
appliances. Insufficient ventilation may cause oxygen shortage.
Do not operate the buttons with wet hand. It may cause electric shock.
2
For safety, turn the circuit breaker off when not using the unit for an extended period of
3
time.
Check the outdoor unit mounting rack periodically for wear and to make sure it is firmly
4
in place.
Do not put anything on the outdoor unit nor step on it. The object or the person may fall
5
down or drop, causing injury.
This unit is designed for residential use. Do not use for other applications such as in a
6
kennel or greenhouse to raise animals or grow plants.
Do not place a vessel with water on the unit. If water penetrates into the unit, electrical
7
insulations may deteriorate and cause electric shock.
Do not block the air inlets nor outlets of the unit. It may cause insufficient performance
8
or troubles.
Be sure to stop the operation and turn the circuit breaker off before performing any
9
maintenance or cleaning. A fan is rotating inside the unit and you may get injured.
Do not splash or pour water directly on the unit. Water can cause electrical shock or
10
equipment damage.
This appliance is not intended for use by young children or infirm persons without
11
supervision.
Young children should be supervised to ensure that they do not play with the appliance.
CAUTIONS FOR LOCATION / INSTALLATION
• Make sure to connect the air conditioner to power supply of the rated voltage and
frequency.
Use of a power supply with improper voltage and frequency can result in equipment
damage and possible fire.
• Do not install the unit in a place where inflammable gas may leak. It may cause fire.
Install the unit in a place with minimal dust, fumes and moisture in the air.
• Arrange the drain hose to ensure smooth drainage. Insufficient drainage may cause wetting
of the room, furniture etc.
• Make sure a leak breaker or a circuit breaker is installed, depending on the installation
location, to avoid electrical shock.
E-2
ADDITIONAL NOTES ON OPERATION
OPERATING TEMPERATURE RANGE
INDOOR TEMP. OUTDOOR TEMP.
COOLING
HEATING
D.B. = Dry-bulb W.B. = Wet-bulb
upper limit
lower limit
upper limit
lower limit
32˚C D.B.43˚C D.B.
23˚C W.B. -
21˚C D.B.21˚C D.B.
15˚C W.B. -
27˚C D.B.24˚C D.B.
-18˚C W.B.
20˚C D.B.-8.5˚C D.B.
--9.5˚C W.B.
WHEN POWER FAILURE OCCURS
This air conditioner has a memory function to store settings when a power failure occurs.
After power recovery, the unit will automatically re-start in the same settings which were active before
the power failure, except for timer settings.
If the timers were set before a power failure, they will need to be re-set after power recovery.
PREHEATING FUNCTION
In the HEAT operation, the indoor fan may not start for two to five minutes after the unit is turned on
to prevent cold air from blowing out of the unit.
DE-ICING FUNCTION
• When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an
automatic de-icer provides heat for about 5 to 10 minutes to remove the ice. During de-icing, the
inside and outside fans stop operating.
• After de-icing is completed, the unit automatically resumes operation in the HEAT mode.
• The built-in protective device may prevent the unit
from operating when used
out of this range.
• Condensation may form on
the air outlet if the unit operates continuously in the
COOL or DRY mode when
humidity is over 80 percent.
ENGLISH
HEATING EFFICIENCY
• The unit employs a heat pump that draws heat from the outside air and releases it into the room.
The outside air temperature therefore greatly affects the heating efficiency.
• If the heating efficiency is reduced due to low outside temperatures, use an additional heater.
• It takes time to warm up and heat the entire room because of the forced air circulation system.
TIPS ON SAVING ENERGY
Below are some simple ways to save energy when you use your air conditioner.
SET THE CORRECT TEMPERATURE
• Setting the thermostat 1°C higher than the desired temperature in the COOL mode and 2°C lower
in the HEAT mode will save approximately 10 percent in power consumption.
• Setting the temperature lower than necessary during cooling operation will result in increased
power consumption.
BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS
• Blocking direct sunlight during cooling operation will reduce power consumption.
• Close the windows and doors during cooling and heating operations.
SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR
CIRCULATION
KEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATION
MAKE MOST OF THE TIMER OFF FUNCTION
DISCONNECT THE POWER CORD WHEN THE UNIT IS NOT USED FOR AN
EXTENDED PERIOD OF TIME
• The indoor unit still consumes a small amount of power when it is not operating.
E-3
PART NAMES
INDOOR UNIT (AY-AP7FHR/AY-AP7FHR-WH/AY-AP9FHR/AY-AP9FHR-WH)
1
1 Inlet (Air)
2
2 Open Panel
3
3 Air Filters
4 AUX. Button
4
5 Indicator
5
6 Receiver Window
6
7 Power Supply Cord
8 Vertical Adjustment Louvre
7
9 Horizontal Adjustment Louvres
8
0 Outlet (Air)
9
q Remote Control
0
q
OUTDOOR UNIT
w PLASMACLUSTER Lamp (blue)
w
e TURBO Lamp (green )
r TIMER Lamp (orange )
e
t OPERATION Lamp (red )
r
t
y
y Inlet(Air)
u Refrigerant Tube and
u
i
o
Interconnecting Cord
i Drainage Hose
o Outlet(Air)
NOTE: Actual units might vary slightly from those shown above.
E-4
INDOOR UNIT (AY-AP12FHR/AY-AP12FHR-WH)
1 AUX. Button
1
2
2 Inlet (Air)
3
3 Open Panel
4 Air Filters
4
5 Indicator
6 Receiver Window
5
7 Vertical Adjustment Louvres
6
8 Horizontal Adjustment Louvres
7
9 Outlet (Air)
8
0 Power Supply Cord
9
q Remote Control
0
q
ENGLISH
OUTDOOR UNIT
w
w PLASMACLUSTER Lamp
(blue)
e TURBO Lamp (green )
r TIMER Lamp (orange )
e
t OPERATION Lamp (red )
r
t
y Inlet (Air)
y
u Refrigerant Tube and
u
i
o
Interconnecting Cord
i Drainage Hose
o Outlet (Air)
NOTE: Actual units might vary slightly from those shown above.
E-5
PART NAMES
REMOTE CONTROL
1
2
3
4
5
6
7
8
9
0
q
w
e
r
t
1 TRANSMITTER
2 DISPLAY (Liquid Crystal Display)
3 ON/OFF Button
4 TEMP. Button
5 DISPLAY Button
6 PLASMACLUSTER Button
7 ONE-HOUR OFF TIMER Button
8 MODE Button
9 TIMER ON Button (for setting the timer)
0 FAN Button
q TIMER OFF Button (for setting the timer)
w SWING Button
e TIMER CANCEL Button
r TURBO Button
t RESET Button
L.C.D. REMOTE CONTROL DISPLAY
y MODE SYMBOLS
: AUTO: HEAT
: COOL: DRY
u TURBO SYMBOL
i PLASMACLUSTER SYMBOL
o FAN SPEED SYMBOLS
: AUTO: Manual setting
p TEMPERATURE AND TIMER COUNT DOWN
INDICATOR
a TRANSMITTING SYMBOL
s TIMER ON/TIMER OFF INDICATOR
Indicates when timer on or timer off is set.
y
u
i
o
p
a
s
E-6
USING THE REMOTE CONTROL
LOADING BATTERIES Use two size-AAA (R03) batteries.
Remove the battery cover at the back
1
of the remote control.
Insert batteries in the compartment,
2
making sure the ± and — polarities
are correctly aligned.
• Lines will be indicated on the display
when batteries are properly installed.
Reinstall the battery cover.
3
Press the RESET button using a thin
4
stick.
NOTES:
• The battery life is approximately one year in normal use.
• When you replace the batteries, always change both batteries, and make sure
they are the same type.
• If the remote control does not operate properly after replacing the batteries, press
the RESET button using a thin stick.
• If you will not be using the unit for a long time, remove the batteries from the
remote control.
Remote control
cover
HOW TO USE THE REMOTE CONTROL
Point the remote control towards the
unit’s signal receiver window and
press the desired button. The unit
generates a beep when it receives
the signal.
• Make sure there is no curtain or other
object between the remote control and
the unit.
• The remote control can send signals from
up to 7 metres away.
ENGLISH
CAUTION
• Do not allow the signal receiver window to receive strong direct sunlight, since it can
adversely affect its operation. If the signal receiver window is exposed to direct sunlight,
close a curtain to block the light.
• Using a fluorescent lamp with a quick starter in the same room may interfere with
transmission of the signal.
• The unit can be affected by signals transmitted from the remote control of a television,
VCR or other equipment used in the same room.
• Do not leave the remote control in direct sunlight or near a heater. Also, protect the unit
and remote control from moisture and shock which can discolour or damage them.
E-7
BASIC OPERATION
2
Press the MODE button to select
1
the operation mode.
AUTOHEATCOOLDRY
Press the ON/OFF button to start
2
operation.
• The red OPERATION lamp ( ) on the
unit will light.
5
3
1
4
TIPS ABOUT AUTO MODE
In the AUTO mode, the temperature setting and mode are automatically selected
according to the room temperature when
the unit is turned on.
Modes and Temperature Settings
Press the TEMP. button to set the
3
desired temperature.
AUTO/DRY MODE
The temperature can be changed in 1°C
increments within the range of 2°C higher
to 2°C lower from the temperature automatically determined by the air conditioner.
COOL/HEAT MODE
The temperature can be set within the
range of 18 to 32°C.
Never attempt to adjust the vertical adjustment louvres manually.
• Manual adjustment of the vertical adjustment louvre can cause the unit to malfunction
when the remote control is used for adjustment.
• When the vertical adjustment louvre is positioned at the lowest position in the COOL or
DRY mode for an extended period of time, condensation may result.
Do not adjust the horizontal adjustment louvre to the extreme left or right in the COOL mode
with the fan speed set to "SOFT(
)" for an extended period of time.
Condensation may form on the louvres.
E-9
PLASMACLUSTER OPERATION
The Plasmacluster ion generator inside the air conditioner will release positive and
negative Plasmacluster ions into the room.
Approximately the same numbers of positive and negative ions released into the air will
reduce some airborne mold.
During operation, press the PLASMACLUSTER
1
button.
• The remote control will display " ".
• The blue PLASMACLUSTER lamp on the unit will
light up.
TO CANCEL
1
Press the PLASMACLUSTER button again.
• The PLASMACLUSTER lamp on the unit will turn
off.
NOTES:
• Use of the PLASMACLUSTER operation will be memorized, and it will be activated the next
time you turn on the air conditioner.
• To turn off the PLASMACLUSTER lamp, press the DISPLAY button.
• When the PLASMACLUSTER button is pressed while the unit is not operating, the
PLASMACLUSTER operation will be performed without accompanying air conditioning mode
(eg, HEATING or COOLING). The mode symbol of the remote control will go off and the fan
speed can not be set AUTO.
E-10
TURBO OPERATION
In this operation, the air conditioner fan works at "extra high" speed with a setting
temperature of 15°C in COOL and DRY modes and 32°C in HEAT mode to rapidly cool
or heat the room.
Press the TURBO button during operation.
1
• The remote control will display " ".
• The temperature display will go off.
• The green TURBO lamp ( ) on the unit will light
up.
TO CANCEL
Press the TURBO button again.
• TURBO operation will also be cancelled when the
operation mode is changed, or when the unit is
turned off.
1
• The green TURBO lamp ( ) on the unit will turn
off.
NOTES:
• You cannot set the temperature or fan speed during TURBO operation.
• After the unit has run for 30 minutes in TURBO operation, the fan setting will become the
"HIGH" speed, and temperature setting will become 18°C in COOL and DRY modes.
• To turn off the TURBO lamp, press the DISPLAY button.
ONE-HOUR OFF TIMER
When the ONE-HOUR OFF TIMER is set, the unit will automatically turn off after one
hour.
Press the ONE-HOUR OFF TIMER button.
1
• The remote control will display “ ”.
• The orange TIMER lamp ( ) on the unit will light
up.
• The unit will stop operating after one hour.
TO CANCEL
Press the CANCEL button.
• The orange TIMER lamp ( ) on the unit will turn
off.
1
NOTES:
• The ONE-HOUR OFF TIMER operation has priority over TIMER ON and TIMER OFF
operations.
• If the ONE-HOUR OFF TIMER is set while the unit is not operating, the unit will operate for
an hour at the formerly set condition.
• If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER is
activated, press the ONE-HOUR OFF TIMER button again during operation.
Alternatively, turn the unit off by pressing the
ON/OFF button.
• The red OPERATION lamp ( ) and the orange
TIMER lamp ( ) on the unit will turn off.
ENGLISH
E-11
TIMER OPERATION
TIMER OFF
The unit will turn off automatically according to your setting.
Timer duration can be set from a minimum half an hour (30 minutes) to a maximum
of 12 hours.
Up to 9.5 hours, you can set in half-hour (30-minute) increments, and from 10 to 12
hours, in 1-hour increments.
Point the remote control at the signal receiver window on the unit.
Press the TIMER OFF ( ) button and set
1
the time as desired.
• The time setting will change as you press the
button as follows,
0.5h1.0h1.5h10h11h12h
Hold the button down to speed through the
settings.
) on the unit
1
• The orange TIMER lamp (
will light.
• The unit will generate a beep when it receives the signal.
• The time setting will count down to show the
remaining time.
Display shown when you
set the unit to ture off 2.5
hours later.
TIPS ABOUT TIMER OFF OPERATION
When the TIMER OFF is set, the temperature
setting is automatically adjusted to prevent
the room from becoming excessively cold
while you sleep. (Auto Sleep function)
COOL/DRY MODE:
• One hour after the timer operation begins,
the temperature setting rises 1°C higher
than the original temperature setting.
HEAT MODE:
• One hour after the timer operation begins,
the temperature setting drops 3°C lower
than the original temperature setting.
E-12
TO CANCEL TIMER
Press the CANCEL button.
• The orange
TIMER lamp
(
) on the
unit will turn
off.
TO CHANGE TIMER SETTING
Press the TIMER button which you wish to
change, (TIMER OFF or TIMER ON) and
change the time setting.
TIMER ON
The unit will turn on automatically according to your setting.
Timer duration can be set from a minimum of half an hour (30 minutes) to a
maximum of 12 hours.
Up to 9.5 hours, you can set in half-hour (30 minute) increments, and from 10 to 12
hours, in 1-hour increments.
Point the remote control at the signal reciever window
on the unit.
Press the TIMER ON ( ) button.
1
• The time setting will change as you press the
button as follows.
0.5h1.0h1.5h10h11h12h
Hold the button down to speed through the setting.
• The orange TIMER lamp (
1
light.
• The unit will generate a beep when it receives
the signal.
• The time setting will count down to show the
remaining time.
) on the unit will
ENGLISH
Select the mode, temperature and fan speed setting as desired.
• When the temperature is set with the TIMER ON, the
temperature will show in the display for 5 seconds
and then return to the time display.
• If you do not change the setting, the unit will operate
Display shown when you
set the unit to reach the
desired room temperature
6.5 hours later.
NOTES ON TIMER SETTING AND OPERATION
• The latest time setting will be memorized and will appear on the remote control display
the next time you set the TIMER OFF or TIMER ON.
• The TIMER OFF and TIMER ON can not be set together.
Only the most recent TIMER setting will be valid.
• While ONE-HOUR OFF TIMER is set, the TIMER OFF and TIMER ON setting are
unavailable.
• If the ONE-HOUR OFF TIMER is set while the TIMER OFF or TIMER ON is activated,
the TIMER ON or TIMER OFF setting will be cancelled.
using the most recent settings.
• The unit will turn on prior to the set time to allow the
room to reach the desired temperature by the programmed time. (Awaking function)
E-13
AUXILIARY MODE
Use this mode when the remote control is not available.
TO TURN ON
Lift the front panel of the indoor unit and press the
AUX. button on the operation panel.
• The red OPERATION lamp (
light and the unit will start operating in the AUTO
mode.
• The fan speed and temperature setting are set to
AUTO.
) on the unit will
TO TURN OFF
Press the AUX. button on the operation panel again.
• The red OPERATION lamp (
turn off.
) on the unit will
NOTE:
If the AUX. button is pressed during normal operation, the unit will turn off.
(AY-AP7FHR/AY-AP7FHR-WH)
(AY-AP9FHR/AY-AP9FHR-WH)
(AY-AP12FHR/AY-AP12FHR-WH)
E-14
MAINTENANCE
Be sure to disconnect the power cord from the wall outlet or turn off the circuit
breaker before performing any maintenance.
CLEANING THE FILTERS
1
2
3
2
1
3
The air filters should be cleaned every two weeks.
TURN OFF THE UNIT
1
REMOVE THE FILTERS
2
1 Lift the open panel.
2 Push the air filters up slightly to un-
lock them.
3 Pull the air filters down to remove
them.
CLEAN THE FILTERS
3
Use a vacuum cleaner to remove dust.
If the filters are dirty, wash them with
warm water and a mild detergent. Dry
filters in the shade before reinstalling.
REINSTALL THE FILTERS
4
1 Reinstall the filters in the original po-
sitions.
2 Close the open panel.
3 Push the arrow-marked points shown
left firmly to lock it in place.
ENGLISH
CLEANING THE UNIT AND THE REMOTE CONTROL
• Wipe them with a soft cloth.
• Do not directly splash or pour water on them, or it can cause electrical shock or
equipment damage.
• Do not use hot water, thinner, abrasive powders or strong solvents.
MAINTENANCE AFTER AIR
CONDITIONER SEASON
Operate the unit in the COOL
1
mode, temperature setting 32°C,
for about half a day to allow the
mechanism to thoroughly dry.
Stop the operation and unplug the
2
unit. Turn off the circuit breaker, if
you have one exclusively for the air
conditioner.
Clean the filters, then reinstall
3
them.
E-15
MAINTENANCE BEFORE
AIR CONDITIONER SEASON
Make sure that the air filters are
1
not dirty.
Make sure that nothing obstructs
2
the air inlet or outlet.
Check the outdoor mounting rack
3
periodically for wear and to make
sure it is firmly in place.
BEFORE CALLING FOR SERVICE
The following conditions do not denote equipment malfunctions
UNIT DOES NOT OPERATE
The unit will not operate if it is turned on immediately
after it is turned off. The unit will not operate
immediately after the mode is changed. This is to
protect the internal mechanisms. Wait 3 minutes
before operating the unit.
UNIT DOES NOT SEND OUT WARM AIR
The unit is preheating or de-icing.
ODORS
Carpet and furniture odors that entered into the
unit and the air conditioner's inner component
odors at the early stage of installation may be sent
out from the unit.
CRACKING NOISE
The unit may produce a cracking noise. This sound
is generated by the friction of the front panel and
other components expanding or connecting due to a
temperature change.
A LOW BUZZING NOISE EMITTED
This is a sound emitted when the unit is generating
Plasmacluster ions.
SWISHING NOISE
The soft, swishing noise is the sound of the refrigerant flowing inside the unit.
WATER VAPOUR
• In the COOL and DRY operation, water vapour
can sometimes be seen at the air outlet due to
the difference between the room air temperature and the air discharged by the unit.
• In the HEAT operation, water vapour may flow
out of the outdoor unit during de-icing.
ODOR EMITTED FROM THE
PLASMACLUSTER AIR OUTLET
This is the smell of ozone generated from the
Plasmacluster Ion generator. The ozone
concentration is very small, posing no adverse
effect on your health. The ozone discharged into
the air rapidly decomposes, and its density in the
room will not increase.
If the unit appears to be malfunctioning, check the following points before calling for
service.
IF THE UNIT FAILS TO OPERATE
Check to see if the circuit breaker has tripped or the fuse has blown.
IF THE UNIT FAILS TO COOL (OR HEAT) THE ROOM EFFECTIVELY
Check the filters. If dirty, clean
them.
Make sure windows and doors
are closed tightly.
Check the outdoor unit to make
sure nothing is blocking the air inlet or outlet.
A large number of people in the
room can prevent the unit from
achieving the desired temperature.
Check the thermostat is proper
setting.
Check whether any heat-generating appliances are operating in the room.
IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL
Check whether the remote control batteries have become old
and weak.
Try to send the signal again with
the remote control pointed properly towards the unit’s signal receiver window.
Check whether the remote control batteries are installed with
the polarities properly aligned.
Please call for service when OPERATION lamp and TIMER lamp on the indicator panel blink.
E-16
ENGLISH
Attenzione: Il dispositivo è
contrassegnato da questo
simbolo, che segnala di non
smaltire le apparecchiature
elettriche ed elettroniche
insieme ai normali rifiuti
domestici. Per tali prodotti è
previsto un sistema di
raccolta a parte.
A. Informazioni sullo smaltimento per gli utenti (privati)
1. Nell'Unione europea
Attenzione: Per smaltire il presente dispositivo, non utilizzare il normale bidone della
spazzatura!
Le apparecchiature elettriche ed elettroniche usate devono essere gestite a parte e in
conformità alla legislazione che richiede il trattamento, il recupero e il riciclaggio
adeguato dei suddetti prodotti.
In seguito alle disposizioni attuate dagli Stati membri, i privati residenti nella UE
possono conferire gratuitamente le apparecchiature elettriche ed elettroniche usate a
centri di raccolta designati*.
In alcuni paesi*, anche il rivenditore locale può ritirare gratuitamente il vecchio prodotto se
l'utente acquista un altro nuovo di tipologia simile.
*) Per maggiori informazioni si prega di contattare l'autorità locale competente.
Se le apparecchiature elettriche o elettroniche usate hanno batterie o accumulatori, l'utente
dovrà smaltirli a parte preventivamente in conformità alle disposizioni locali.
Lo smaltimento corretto del presente prodotto contribuirà a garantire che i rifiuti siano
sottoposti al trattamento, al recupero e al riciclaggio necessari prevenendone il
potenziale impatto negativo sull'ambiente e sulla salute umana, che potrebbe derivare
da un'inadeguata gestione dei rifiuti.
2. In paesi che non fanno parte dell'UE
Se si desidera eliminare il presente prodotto, contattare le autorità locali e informarsi
sul metodo di smaltimento corretto.
Per la Svizzera: Le apparecchiature elettriche o elettroniche usate possono essere
restituite gratuitamente al rivenditore, anche se non si acquista un prodotto nuovo.
Altri centri di raccolta sono elencati sulle homepage di
www.swico.cho di www.sens.ch.
. Informazioni sullo smaltimento per gli utenti commerciali
B
1. Nell'Unione europea
Se il prodotto è impiegato a scopi commerciali, procedere come segue per eliminarlo.
Contattare il proprio rivenditore SHARP che fornirà informazioni circa il ritiro del
prodotto. Potrebbero essere addebitate le spese di ritiro e riciclaggio. Prodotti piccoli
(e quantitativi ridotti) potranno essere ritirati anche dai centri di raccolta locali.
Per la Spagna: Contattare il sistema di raccolta ufficiale o l'ente locale preposto al
ritiro dei prodotti usati.
2. In paesi che non fanno parte dell'UE
Se si desidera eliminare il presente prodotto, contattare le autorità locali e informarsi
sul metodo di smaltimento corretto.
IT
ITALIANO
Grazie per aver acquistato il condizionatore d’aria SHARP. Leggete attentamente questo
manuale prima di usare il prodotto.
INDICE
• IMPORTANTI ISTRUZIONI PER
LA SICUREZZA .......................................... I-1
• ULTERIORI NOTE RIGUARDANTI
IL FUNZIONAMENTO ................................. I-3
• SUGGERIMENTI PER
RISPARMIARE ENERGIA .......................... I-3
• NOMI DEI COMPONENTI .......................... I-4
• USO DEL TELECOMANDO ....................... I-7
• FUNZIONI DI BASE .................................... I-8
• REGOLAZIONE DELLA DIREZIONE
DEL FLUSSO D’ARIA ................................. I-9
Non tirate o deformate il cavo di alimentazione. Se si tira o si usa erratamente il cavo,
1
l’unità si può danneggiare e provocare scosse elettriche.
Fate attenzione a non esporvi direttamente all’uscita dell’aria per un lungo periodo di
2
tempo. Potrebbe danneggiare la vostra salute.
Nel caso si usi il condizionatore d’aria in presenza di neonati, bambini, persone anziane,
3
persone costrette a stare a letto o persone con handicap fisici, assicuratevi prima che la
temperatura della stanza sia confortevole per tali persone.
Non inserite mai oggetti nell’unità. Ciò potrebbe portare a lesioni a causa dell’alta velocità
4
di rotazione dei ventilatori interni.
Collegate correttamente il condizionatore d’aria a terra. Non collegate il cavo a terra al
5
tubo del gas, al tubo dell’acqua, al parafulmini o al cavo a terra del telefono. Un collegamento a terra incompleto potrebbe causare scossa elettrica.
In caso di anomalie del condizionatore d’aria (ad esempio, odore di bruciato), interrompete
6
subito l’uso e SPEGNETE l’interruttore di circuito.
L’apparecchio deve essere installato in conformità con i regolamenti di connessione
7
elettrica nazionali. Un collegamento scorretto del cavo può provocare il surriscaldamento
del cavo di alimentazione, della spina e della presa elettrica e causare un incendio.
Se è danneggiato il cavo di alimentazione, bisogna far sostituire lo stesso dal fabbricante
8
o da un centro di assistenza o da una persona qualificata per evitare eventuali rischi.
Sostituite il cavo di alimentazione solo con un altro specificato dal produttore.
ITALIANO
AVVERTIMENTI PER L’INSTALLAZIONE/RIMOZIONE/
RIPARAZIONE
• Non cercate di installare/rimuovere/riparare l’unità senza assistenza. Un uso errato causerà
scosse elettriche, perdite d’acqua, incendi e così via. Consultate il vostro rivenditore o
dell’altro personale di servizio qualificato per l’installazione/rimozione/riparazione dell’unità.
I-1
IMPORTANTI ISTRUZIONI PER LA SICUREZZA
PRECAUZIONI PER L’USO
Aprite una finestra o una porta periodicamente per ventilare la stanza, specialmente
1
quando si usano apparecchi a gas. Una ventilazione insufficiente potrebbe causare mancanza di ossigeno.
Non toccate i tasti con mani bagnate. Ciò potrebbe provocare una scossa elettrica.
2
Per sicurezza, spegnete l’interruttore del circuito quando non usate l’unità per un lungo
3
periodo di tempo.
Controllate la cremagliera di montaggio dell’unità esterna periodicamente ed assicuratevi
4
che sia ben fissata.
Non urtate l’unità esterna e non collocate alcun oggetto sopra di essa, poiché potrebbe
5
cadere causando lesioni personali.
Questa unità è stata progettata per l’uso in aree residenziali. Non usatela in canili o serre
6
per allevare animali o coltivare piante.
Non collocate contenitori d’acqua sull’unità. Se l’acqua penetra nell’unità, l’isolamento
7
elettrico si potrebbe rovinare causando una scossa elettrica.
Non bloccate gli sbocchi d’uscita ed entrata dell’aria dell’unità. Ciò potrebbe compro-
8
metterne il funzionamento o provocare guasti.
Assicuratevi di spegnere l’apparecchio e l’interruttore di circuito prima di eseguire lavori
9
di manutenzione o pulitura. Il ventilatore che gira all’interno dell’unità potrebbe provocarvi
lesioni.
Non spruzzate o gettate acqua direttamente sull’unità. L’acqua potrebbe causare una
10
scossa elettrica o danni all’apparecchio.
Questo apparecchio non deve essere usato da bambini o persone inferme senza super-
11
visione.
Assicuratevi che i bambini non giochino con l’apparecchio.
PRECAUZIONI PER IL LUOGO DI MONTAGGIO/
INSTALLAZIONE
• Assicuratevi di collegare il condizionatore d’aria ad una presa di corrente di voltaggio e
frequenza giusta.
L’uso di una presa di corrente dal voltaggio e frequenze errate potrebbe risultare dannoso
all’apparecchio e provocare un incendio.
• Non installate l’unità in un luogo dove ci potrebbero essere perdite di gas infiammabile.
Ciò potrebbe provocare incendi.
Non collocate l’unità in luoghi nei quali l’aria contiene polvere, fumi oppure umidità in misura
eccessiva.
• Sistemate il tubo di drenaggio in modo tale da assicurare un drenaggio corretto. Un drenaggio
insufficiente potrebbe far fuoriuscire acqua nella stanza, bagnare i mobili e così via.
• Assicuratevi di installare un interruttore differenziale o magnetotermico a seconda del luogo
d’installazione, per evitare scosse elettriche.
I-2
ULTERIORI NOTE RIGUARDANTI IL FUNZIONAMENTO
INTERVALLO DELLA TEMPERATURA DI ESERCIZIO
TEMP. INTERNA TEMP. ESTERNA
RAFFREDDAMENTO
RISCALDAMENTO
B.A. = Bulbo asciutto B.B. = Bulbo bagnato
limite32°C B.A.43°C B.A.
superiore23°C B.U. -
limite21°C B.A.21°C B.A.
inferiore15°C B.U. -
limite27°C B.A.24°C B.A.
superiore -18°C B.U.
limite20°C B.A.-8,5°C B.A.
inferiore --9,5°C B.U.
SE SI VERIFICA UN GUASTO DELL’ALIMENTAZIONE
Se si verifica un guasto dell’alimentazione, il condizionatore d’aria è dotato di una funzione di memoria
che memorizza le impostazioni.
Dopo il ripristino dell’alimentazione, l’unità riprenderà il funzionamento con le stesse impostazioni di
prima, fatta eccezione per il funzionamento con il timer.
Se i timer sono stati impostati prima del guasto dell’alimentazione, dovranno essere reimpostati dopo
il ripristino dell’alimentazione.
FUNZIONE DI PRERISCALDAMENTO
Nel modo di RISCALDAMENTO, il ventilatore interno potrebbe non funzionare per due – cinque minuti dopo l’accensione dell’unità per evitare che esca aria fredda.
FUNZIONE DI SBRINAMENTO
• Quando sullo scambiatore di calore dell’unità esterna si forma del ghiaccio nel modo di funzionamento
RISCALDAMENTO, un sistema di sbrinamento automatico fornisce calore per circa 5-10 minuti per
eliminare il ghiaccio. Durante lo sbrinamento, i ventilatori interni ed esterni si fermano.
• Una volta completato lo sbrinamento, l’unità riprende il funzionamento automaticamente nel modo
RISCALDAMENTO.
• Il sistema di protezione incorporato potrebbe interrompere
il funzionamento dell’unità
quando la si utilizza fuori da
questo intervallo.
•
Si potrebbe formare della
condensa sull’uscita dell’aria
se l’unità opera in modo
continuo nel modo RINFRESCAMENTO o DEUMIDIFICAZIONE quando l’umidità è
al di sopra dell’80%.
ITALIANO
EFFICIENZA DEL RISCALDAMENTO
• L’unità usa una pompa di calore che raccoglie calore dall’aria esterna e lo diffonde nella stanza. Di
conseguenza, la temperatura dell’aria esterna influisce notevolmente sull’efficacia del riscaldamento.
• Se la capacità di riscaldamento è notevolmente ridotta a causa di una bassa temperatura esterna,
utilizzate un riscaldatore addizionale.
•
Per riscaldare tutto l’ambiente occorrerà del tempo, in quanto l’unità adotta un sistema a circolazione forzata.
SUGGERIMENTI PER RISPARMIARE ENERGIA
Qui di seguito sono presentati alcuni semplici metodi per risparmiare energia durante l’uso del condizionatore d’aria.
IMPOSTATE LA TEMPERATURA CORRETTA
•
Impostando il termostato 1°C in più della temperatura desiderata nel modo RINFRESCAMENTO (e 2°C
in meno nel modo RISCALDAMENTO) si risparmierà circa il 10 percento di energia.
• Impostando una temperatura più bassa del necessario durante l’operazione di raffreddamento, si
consumerà più energia.
RIPARATE DALLA LUCE SOLARE DIRETTA ED EVITATE CORRENTI D’ARIA
• Evitando la luce solare diretta durante l’operazione di raffreddamento si risparmierà energia.
• Chiudete le finestre e le porte durante le operazioni di raffreddamento e riscaldamento.
IMPOSTATE LA GIUSTA DIREZIONE DEL FLUSSO D’ARIA PER OTTENERE
LA MIGLIOR CIRCOLAZIONE D’ARIA
MANTENETE IL FILTRO PULITO PER GARANTIRE UN FUNZIONAMENTO PIÙ EFFICACE
RICAVATE IL MASSIMO VANTAGGIO DALLA FUNZIONE DI TIMER DISATTIVATO
DISINSERITE IL CAVO DI ALIMENTAZIONE QUANDO L’UNITÀ NON VIENE
USATA PER UN LUNGO PERIODO DI TEMPO
• L’unità interna continua a consumare una piccola quantità di energia quando non è in funzione.
NOTA: Le unità effettive potrebbero differire leggermente da quelle illustrate sopra.
I-4
UNITÀ INTERNA (AY-AP12FHR/AY-AP12FHR-WH)
1
2
3
4
5
6
7
8
9
0
q
1 Tasto AUX.
2 Entrata (dell’aria)
3 Pannello aperto
4 Filtri dell’aria
5 Indicatore
6 Finestra di ricezione
7 Deflettori di regolazione
verticale
8 Deflettori di regolazione
orizzontale
9 Uscita (d’aria)
0 Cavo d’alimentazione
q Telecomando
UNITÀ ESTERNA
w
w Spia PLASMACLUSTER
(blu)
e Spia TURBO (verde )
r Spia TIMER (arancione )
e
t Spia di FUNZIONAMENTO
r
t
y
u
i
o
(rossa )
y Entrata (dell’aria)
u Tubo refrigerante e cavo
di interconnessione
i Tubo di drenaggio
o Uscita (d’aria)
ITALIANO
NOTA: Le unità effettive potrebbero differire leggermente da quelle illustrate sopra.
I-5
NOMI DEI COMPONENTI
TELECOMANDO
1
2
3
4
5
6
7
8
9
0
q
w
e
r
t
1 TRASMETTITORE
2 DISPLAY (display a cristalli liquidi)
3 Tasto d’ACCENSIONE/SPEGNIMENTO
4 Tasto TEMP.
5 Tasto DISPLAY
6 Tasto PLASMACLUSTER
7 Tasto TIMER DI SPEGNIMENTO DOPO
UN’ORA
8 Tasto MODE (MODO)
9 Tasto TIMER ATTIVATO
(per impostare il timer)
0 Tasto FAN (VENTILATORE)
q Tasto TIMER DISATTIVATO
(per impostare il timer)
w Tasto SWING (ROTAZIONE)
e Tasto CANCEL (ANNULLA)
r Tasto TURBO
t Tasto RESET
DISPLAY LDC DEL TELECOMANDO
y SIMBOLI DEL MODO
: AUTOMATICO: RISCALDAMENTO
: RINFRESCA-: DEUMIDIFI MENTO CAZIONE
u SIMBOLO TURBO
i SIMBOLO PLASMACLUSTER
o SIMBOLI DI VELOCITÀ DEL VENTILATORE
: AUTO-: Impostazione manuale
MATICO
p INDICATORE CONTEGGIO TIMER E TEMPERATURA
a SIMBOLO DI TRASMISSIONE
s INDICATORE TIMER ATTIVATO/DISATTIVATO
Indica quando il timer è attivato o disattivato.
y
u
i
o
p
a
s
I-6
USO DEL TELECOMANDO
INSERIMENTO DELLE BATTERIE
Utilizzatedue batterie di dimensioni AAA (R03).
Rimuovete il coperchio delle batterie
1
sul retro del telecomando.
Inserite le batterie nel comparto, assi-
2
curandovi che le polarità ± e — siano
allineate correttamente.
• Quando le batterie vengono installate
correttamente, le linee verranno indicate sul display.
Reinserite il coperchio delle batterie.
3
Premete il tasto RESET utilizzando un
4
bastoncino sottile.
NOTE:
• In condizioni di uso normali, le batterie durano circa un anno.
• Quando cambiate le batterie, utilizzate sempre due batterie dello stesso tipo.
• Se il telecomando non funziona correttamente dopo avere sostituito le batterie,
premere il tasto RESET utilizzando un bastoncino.
• Se non intendete usare l’unità per un lungo periodo di tempo, togliete le batterie dal
telecomando.
Coperchio del
telecomando
ITALIANO
COME USARE IL TELECOMANDO
Puntate il telecomando verso la finestra di ricezione del segnale
dell’unità e premete il tasto desiderato. L’unità emette un segnale acustico “bip” quando riceve il segnale.
• Assicuratevi che non ci siano una tenda
o altri oggetti tra il telecomando e l’unità.
• Il telecomando può inviare segnali fino ad
una distanza di 7 metri.
PRECAUZIONI
• Evitate di esporre la finestra di ricezione alla luce solare diretta, in quanto ne può danneggiare il funzionamento. Se la finestra di ricezione del segnale è esposta alla luce solare
diretta, chiudete la tenda per bloccare la luce.
• L’uso di una lampada fluorescente con una reattanza d’accensione rapida nello stesso
locale può interferire con la trasmissione del segnale.
• L’unità può essere influenzata da segnali trasmessi dal telecomando di un televisore,
videoregistratore o altre attrezzature usate nella stessa stanza.
• Non lasciate il telecomando esposto alla luce solare diretta o vicino ad un radiatore. Inoltre,
proteggete l’unità e il telecomando da umidità e scosse che potrebbero scolorirli o danneggiarli.
I-7
FUNZIONI DI BASE
Premete il tasto MODE per selezio-
1
nare il modo di funzionamento.
AUTO- RISCALDA- RINFRESCA- DEUMIDIFI-
MATICO MENTO
Premete il tasto d’ACCENSIONE/
2
SPEGNIMENTO per accendere
MENTOCAZIONE
l’unità.
2
• La spia rossa di FUNZIONAMENTO
( ) sull’unità si illuminerà.
5
3
1
4
SUGGERIMENTI SUL
MODO AUTOMATICO
Nel modo AUTOMATICO l’impostazione e
il modo della temperatura vengono selezionati automaticamente in base alla temperatura della stanza nel momento in cui
l’unità viene accesa.
Modo e impostazioni della temperatura
Temperatura della
stanza
all’avvio
SottoRISCALDA21°CMENTO
Da 21°CDEUMIDIFI- Temperatura dela 24°CCAZIONEla stanza all’avvio
Da 24°CRINFRESa 26°CCAMENTO
Da 26°CRINFRESa 28°CCAMENTO
SopraRINFRESCA28°CMENTO
Funzionamento automatico
Modo
Impostazione
della temperatura
23°C
24°C
25°C
26°C
Premete il tasto TEMP. per impos-
3
tare la temperatura desiderata.
MODO AUTOMATICO/
DEUMIDIFICAZIONE
La temperatura può essere cambiata in
incrementi di 1°C entro l’intervallo di 2°C
superiore e 2°C inferiore alla temperatura
determinata automaticamente dal condizionatore dell’aria.
MODO RINFRESCAMENTO/
RISCALDAMENTO
La temperatura può essere impostata in
un intervallo compreso tra 18 e 32°C.
Premete il tasto FAN per impostare
4
la velocità del ventilatore desiderata.
AUTO- MODE- BASSO ALTO
MATICO RATO
• Nel modo DEUMIFICAZIONE, la velocità
del ventilatore è preselezionata su AUTOMATICO e non può essere cambiata.
Per spegnere l’unità, premete nuova-
5
mente il tasto d’ACCENSIONE/
SPEGNIMENTO.
• La spia rossa di FUNZIONAMENTO ( )
sull’unità si spegnerà.
I-8
Loading...
+ 64 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.