[Service Information]

 

 

 

 

 

 

CHANGEINAUDINTERFACEHARNESSWIRING.

 

 

 

 

 

1.Model Name:

AR-5132

2.General:

Because the 2P connector harness for the AUD interface harness counter in the control

 

panel unit is too long, it may get caught when the cabinet is being put on during repair.

 

Therefore the changes below have been made to the wiring method.

 

 

LCD control PWB

 

 

 

AUD interface harness

 

White

 

 

 

DHAI-2530FCZZ

 

Wire so it catches

Red

on the boss.

Door SW

OP PWB

Panel side

To OPC PWB

Fastening band

As shown in the diagram above, bend connector C away from fastening band "a", and fasten the harness for connectors B & C 40mm from fastening band a with "a" fastening band.

3.Action: From the 1st lot of 1997 July production.

1/2

 

 

Green

SHARP CORPORATION

Reprography Division

C

 

Ref.

Model

 

 

 

 

Current parts

 

New parts

 

 

Effec-

Inter-

 

 

 

 

 

 

 

 

 

 

 

 

Version

 

P/G No.

 

 

 

 

 

Parts name

tive

change-

Note

No.

name

 

 

 

 

 

Price

 

 

 

 

Parts code

 

Parts code

 

time

ability

 

 

 

 

 

 

 

 

rank

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBNDJ0013FCZZ

 

Q’ty change:

 

 

1st lot

 

 

 

AR-5132

All

 

2

 

 

AA

Fastening band

----

 

 

 

 

(Q’ty: 2)

 

2 3

 

’97/7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Interchange>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Interchangeable.

 

 

 

 

 

 

4. Not interchangeable.

 

 

 

 

 

 

 

 

 

 

2. Current type can be used in place of new type.

 

5. Interchangeable if replaced with same types of

 

New type cannot be used in place of current type.

 

related parts in use.

 

 

 

3. Current type cannot be used in place of new type.

6. Others.

New type can be used in place of current type.

Parts marked with ‘‘ ’’ is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.