AN-PH7LP1
収納部
AN-PH7LP2
収納部
AN-PH7LP2
AN-PH7LP1
ランプ1
ランプ2
ON(電源入)ボタン
ENTER(決定)
ボタン
MENU(メニュー)
ボタン
H&VLENSSHIFT
(縦横レンズシフト)
ボタン
LAMP UNIT (LAMP/CAGE MODULE)
Compartment for
AN-PH7LP1
Compartment for
AN-PH7LP2
AN-PH7LP2
AN-PH7LP1
For Lamp 1
For Lamp 2
ON button
ENTER button
MENU button
H&V LENS
SHIFT
button
FOR PROJECTOR
Model AN-PH7LP1/AN-PH7LP2
INSTALLATION MANUAL
CAUTION:
• Potential hazard of glass particles if lamp ruptures. Please have a Sharp Authorized Projector Dealer or
Service Center* replace lamp if rupture occurs.
• Do not remove the lamp unit directly after operation of the projector. The lamp may be extremely hot. Wait at
least one hour after the power cord is disconnected to allow the surface of the lamp unit to fully cool before
removing the lamp unit.
■
It is recommended that the lamp be replaced when the remaining lamp life becomes 5% or less, or when you notice a significant deterioration in the picture and color quality. The lamp life (percentage) can be checked with the on-screen display.
IMPORTANT NOTE TO U.S. CUSTOMERS:
The lamp included with this projector is backed by a 90-day parts and labor limited warranty. All service of this
projector under warranty, including lamp replacement, must be obtained through a Sharp Authorized Projector
Dealer or Service Center*. For the name of the nearest Sharp Authorized Projector Dealer or Service Center*,
please call toll-free: 1-888-GO-SHARP (1-888-467-4277).
Hg LAMP CONTAINS MERCURY For State Lamp Disposal Information
www.lamprecycle.org or 1-800-BE-SHARP
U.S.A. ONLY
4 Remove the lamp unit.
• Loosen the securing screws (two for each lamp)
from the lamp unit. Hold the lamp unit by the
handle and pull it in the direction of the arrow.
At this time, keep the lamp unit horizontal and
do not tilt it.
5 Insert the new lamp unit.
• Press the lamp unit firmly into the lamp unit
compartment. Fasten the securing screws.
• Be sure that AN-PH7LP1 and AN-PH7LP2 are
respective type.
6 Replace the lamp unit cover.
• Align the lamp unit cover and slide it to close.
Then tighten the user service screw to secure
the lamp unit cover.
* Confirm the name of the Dealer or Service Center referring to your projector operation manual.
Removing and Installing the
Lamp Unit
• Ensure the lamp unit is removed using the handle.
Ensure the glass surface of the lamp unit or the
inside of the projector are not touched.
• To avoid injury to yourself and damage to the lamp,
be sure to carefully follow the steps below.
• Do not loosen other screws except for the lamp unit
cover and lamp unit.
(Only the silver screws are loosened.)
1 Press on the projector or
on the remote control to put the projector into standby mode.
• Wait until the cooling fan stops.
Warning!
• Do not remove the lamp unit from the projector
right after use. The lamp and parts around the
lamp will be very hot and may cause burn or
injury.
2 Disconnect the power cord.
• Unplug the power cord from the AC socket.
• Leave the lamp until it has fully cooled down
(about 1 hour).
3 Remove the lamp unit cover.
• Loosen the user service screw (1) that secures the lamp unit cover. Remove the lamp
unit cover (2).
• If the lamp unit and lamp unit cover are not correctly installed, the power will not turn on, even if
the power cord is connected to the projector.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
• Make sure to reset the lamp timer only when replacing the lamp. If you reset the lamp timer and
continue to use the same lamp, this may cause the
lamp to become damaged or explode.
1 Connect the power cord.
•
Plug the power cord into the AC socket of the projector.
2 Reset the lamp timer.
For Lamp 1
• When you reset the timer for AN-PH7LP1, while
simultaneously holding down
press
• “LAMP 1 100%” is displayed, indicating that the
lamp timer is reset.
For Lamp 2
• When you reset the timer for AN-PH7LP2, while
simultaneously holding down
press
• “LAMP 2 100%” is displayed, indicating that the
lamp timer is reset.
on the projector.
on the projector.
and ,
and ,
Printed in China
9NK5010058300
06P12-CH-NM
シャーププロジェクター用
ランプ交換ユニット
形名
ランプ交換説明書ランプ交換説明書
ランプ交換説明書
ランプ交換説明書ランプ交換説明書
ランプユニットに関しての注意
∫ ランプには、内部圧力の高い水銀ランプ(高輝度放電ランプ(H I D ランプ))が使われています。当ランプは衝撃やキズ、使用
時間の経過による劣化などで、大きな音をともなって破裂したり、不点灯状態となって寿命が尽きたりする特性があります。ま
た、当ランプは、個体差や使用条件によって破裂や不点灯にいたるまでの時間に大きな差があります。
∫ ランプが破裂したときは、プロジェクター内部にガラスの破片が飛び散ったり、ランプ内部のガスがプロジェクターの排気
孔から出たりすることがあります。当ランプ内部のガスには水銀が含まれていますので破裂した場合は十分な換気をしてく
ださい。万一吸い込んだり、目に入ったり口に入った場合には、すみやかに医師にご相談ください。
∫ ランプが破裂したときは、サービスマンまたは販売店に内部の点検を依頼してください。
∫ ランプを廃棄する際は
この高輝度放電ランプ(H I D ランプ)は、微量な水銀を含有しています。これらの含有物は、環境考慮の観点から法的に規制さ
れている場合があります。廃棄やリサイクルについては、関連法規およびお住まいの地域条例などに従って処理してください。
AN-PH7LP1/AN-PH7LP2AN-PH7LP1/AN-PH7LP2
AN-PH7LP1/AN-PH7LP2
AN-PH7LP1/AN-PH7LP2AN-PH7LP1/AN-PH7LP2
ランプ交換のしかた
4 ランプユニットを取り外す
∫
ランプユニットの固定ネジ(それぞれ2ヶ所)をゆる
め、取っ手をつかんでランプユニットを水平に保ちな
がら傾けな い ようにして 矢印の 方 向 に 引 き 出します。
5 新しいランプユニットを挿入する
∫ ランプユニットをしっかりとランプユニット収納部に
押し込みます。固定ネジをしめます。
∫ ランプ ユニットを交換するときは、AN-PH7LP1、
AN-PH7LP2、それぞれの収納部に合ったランプユ
ニットを使用してください。
6 ランプユニットカバーを取り付ける
∫
ランプユニットカバーを本体に合わせてからスライド
させランプユニットカバーを取り付けます。ランプ 交
換用ネジを閉め、ランプユニットカバーを固定します。
∫ 電源コードが接続されていてもランプユニットとランプユ
ニットカバーが正しく取り付けられていないと、電源が入
りませ ん 。
∫ 取っ手をつかんで、ランプ ユニットを 取り外してくだ
さい。ランプユニットのガラス表面やプロジェクター
本体の内部には触れないでください。
∫ ケガやランプの破損を防ぐため、手順にそって作業を
行ってください 。
∫
ランプユニットカバーとランプユニット以外のネジは絶
対に外さないでください。(銀色のネジ以外はゆるめない
でくださ い 。)
1 本体の また はリモコンの を押
しプロジェクターを待機状態にする
∫ 冷却ファンが止まるまで待ちます。
∫
ランプユニットは、操作直後にプロジェクター
から取り外さ な い でくださ い 。ランプおよび
その周辺が高温になっていることがあり、や
けどの原因となります。
2 電源コードをプロジェクターから取り外す
∫ 電源コードをAC電源ソケットから外します。
ララ
∫
ラ
ララ
まま
ま
まま
3 ランプユニットカバーを取り外す
∫ ランプユニットカバーを固定しているランプ交換用ネ
ジをゆるめます(1)。矢印の方向にスライドさせて
ランプユニットカバーを取り外します(2)。
ンン
ププ
ユユ
ニニ
ッッ
トト
ン
プ
ユ
ンン
ププ
ユユ
すす
。。
す
。
すす
。。
がが
ニ
ッ
ト
が
ニニ
ッッ
トト
がが
十十
分分
冷冷
ええ
十
十十
るる
分
冷
え
る
分分
冷冷
ええ
るる
まま
ま
まま
でで
で
でで
((
(
((
約約
約
約約
ランプ使用時間をリセットする
ランプ交換を行ったときは、ランプ使用時間をリセットしてく
ださい。
∫ ランプ使用時間のリセットは、ランプ交換時以外は行わな
いでください。ランプ使用時間をリセットし て 、規定以上
ランプを使用すると破裂や故障の原因になります。
1 電源コードをプロジェクターに接続する
∫ 電源コードをプロジェクターのAC電源ソケットに接
続します。
2 ランプ使用時間をリセットする
ランプ1
∫
AN-PH7LP1側をリセットするときは、本体の
と を同時に押しながら、 を押します。
∫ ランプ使用時間がリセットされ、「LAMP1 100%」
11
時時
間間
))
放放
置置
)
))
放
放放
置
置置
しし
し
しし
1
時
間
11
時時
間間
が表示されます。
ランプ2
∫
AN-PH7LP2側をリセットするときは、本体の
と を同時に押しながら、 を押します。
∫ ランプ使用時間がリセットされ、「LAMP2 100%」
が表示されます。