This INSTALLATION AND OPERATION
MANUAL explains the proper use of your new
Sharp Air Conditioner. Read these instructions
carefully before installing or operating your air
conditioner. The INSTALLATION AND OPERATION MANUAL should be kept in a safe
place for handy reference.
• PARTS NAMES ...................................10
• COOLING OPERATION ......................11
TO CHANGE TEMPERATURE SETTING..........
•
TO CHANGE FAN SPEED AND OPERATION MODE..
•
• ENERGY SAVER.................................13
TO CHANGE AIR FLOW DIRECTION .......
•
• ON TIMER OPERATION .....................14
• OFF TIMER OPERATION....................15
• USING THE REMOTE CONTROL.......16
CLEANING AND MAINTENANCE ........ 18
BEFORE CALLING FOR SERVlCE...... 19
PAGE
11
12
13
As an ENERGY STAR Partner, Sharp Electronics has determined that this product (AF-S80CX) meets the
ENERGY STAR guidelines for energy efficient air conditioners. To meet these guidelines, air conditioners
must be at least 15% more efficient than the minimum Federal standard.
FOR YOUR PROTECTION
To aid in answering questions if you call for service or for reporting loss or theft, please record
below the model and serial number located on the right side of the unit.
MODEL NUMBER
SERIAL NUMBER
DATE OF PURCHASE
Dealer Name
Address
City
State
Zip
Telephone
TO PHONE: Dial 1-800-BE-SHARP (237-4277) for:
SERVICE (for your nearest Sharp Authorized Servicer)
PARTS (for your Authorized Parts Distributor)
ACCESSORIES
ADDITIONAL CUSTOMER INFORMATION
TO WRITE: For service problems, warranty information, missing items and other assistance:
Sharp Electronics Corporation
Customer Assistance Center
1300 Naperville Drive
Romeoville, IL 60446-1091
Please provide the following information when you write or call: model number, serial number,
date of purchase, your complete mailing address (including zip code), your daytime telephone
number (including area code) and description of the problem.
2
CONSUMER LIMITED WARRANTY
CONSUMER LIMITED WARRANTY
SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "Product"),
when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option,
either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to
the purchaser for parts or labor for the period(s) set forth below.
This warranty does not apply to any appearance items of the Product nor to the additional excluded item(s) set forth below nor
to any Product the exterior of which has been damaged or defaced, which has been subjected to improper voltage or other misuse,
abnormal service or handling, or which has been altered or modified in design or construction.
In order to enforce the rights under this limited warranty, the purchaser should follow the steps set forth below and provide proof
of purchase to the servicer.
The limited warranty described herein is in addition to whatever implied warranties may be granted to purchasers by law. ALL
IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE ARE LIMITED
TO THE PERIOD(S) FROM THE DATE OF PURCHASE SET FORTH BELOW. Some states do not allow limitations on how long
an implied warranty lasts, so the above limitation may not apply to you.
Neither the sales personnel of the seller nor any other person is authorized to make any warranties other than those described
herein, or to extend the duration of any warranties beyond the time period described herein on behalf of Sharp.
The warranties described herein shall be the sole and exclusive warranties granted by Sharp and shall be the sole and exclusive
remedy available to the purchaser. Correction of defects, in the manner and for the period of time described herein, shall constitute
complete fulfillment of all liabilities and responsibilities of Sharp to the purchaser with respect to the Product, and shall constitute
full satisfaction of all claims, whether based on contract, negligence, strict liability or otherwise. In no event shall Sharp be liable,
or in any way responsible, for any damages or defects in the Product which were caused by repairs or attempted repairs performed
by anyone other than an authorized servicer. Nor shall Sharp be liable or in any way responsible for any incidental or consequential
economic or property damage. Some states do not allow the exclusion of incidental or consequential damages, so the above
exclusion may not apply to you.
THIS WARRANTY GIVES YOU SPECIFlC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM
STATE TO STATE.
Your Product Model Number & Description:
Warranty Period for this Product:
Additional Item(s) Excluded From
Warranty Coverage (If any):
Where to Obtain Service:
What to Do to Obtain Service:
TO OBTAIN SUPPLY, ACCESSORY OR PRODUCT INFORMATION, GO TO OUR WEBSITE AT www.sharp-usa.com
AF-S80CX, AF-R80CX, or AF-R85CX Room Air Conditioner. Be sure to
have this information available when you need service for your Product.
One (1) year parts and labor from date of purchase. The warranty
period continues for a total of five (5) years from date of purchase for
the Sealed Cooling System parts; labor and service are not provided
free of charge for this additional period.
Appearance items of the Product, knobs, filter, or accessories, mounting
kit, seals, or any printed materials.
From a Sharp Authorized Servicer located in the United States. To find the
location of the nearest Sharp Authorized Servicer, call Sharp Toll Free at
1-800-BE-SHARP.
Contact your Sharp Authorized Servicer to obtain in-home service for this
Product. The Servicer will come to your home, and if it is necessary to
remove the Product, the Servicer will reinstall it. Be sure to have Proof of
Purchase available.
OR CALL 1-800-BE-SHARP.
SHARP ELECTRONICS CORPORATION
Sharp Plaza, Mahwah, New Jersey 07430-2135
3
INSTALLATION INSTRUCTIONS
Before beginning installation, read these instructions carefully.
Use the enclosed MOUNTING KIT for proper installation.
CHECK WINDOW AREA
The mounting kit is designed for wooden sill double or single hung sash-type windows.
Minimum opening
(Without mounting kit)
19 11/16" (500mm)
Window opening from stool to lower
sash bottom must be 14
or more.
27
/32" (377mm)
Mounting kit fully closed
LOCATION
21 5/ 8" (600mm)
Mounting kit fully opened
7
33
/16" (900mm)
Lower sash bottom
Stool
• The air conditioner should be installed on a firm foundation to minimize noise and vibration.
For safe installation, repairs, replacement and secure positioning, make sure foundation is
solid and level.
• The room air conditioner must be installed in an area within reach of a properly rated
grounded outlet.
• Use of extension cords of any kind is not recommended.
• Never place any obstacles around air inlet.
4
ACCESSORIES
No.
AccessoriesQ'ty
INSTALLATION INSTRUCTIONS
1
1
2
3
4
5
6
7
8
9
10
11
Right closure assembly1
Left closure assembly1
Window sash foam seal1
Window sash foam seal1
(adhesive type)
Bottom gasket1
Screws (L=1", 25.4mm)7
Screws (L= 13/32", 10mm)6
Base pan angle2
Remote control1
Battery2
Remote control hook1
2
3
4
5
10
6
6
7
8
2
11
2
7
9
SUGGESTED TOOLS
1. Screw driver (medium size Phillips)
2. Tape measure or ruler
3. Knife or scissors
5
INSTALLATION INSTRUCTIONS
INSTALLATION
WARNING: Make sure the unit is turned off and unplugged before working.
Cut the window sash foam seal (adhesive
type) to the proper length and attach it to
1
the underside of the window sash.
Insert the right closure assembly and the
left closure assembly into the top angle
2
and the bottom channels.
Secure the right and left closure to the
cabinet with six of the provided screws.
13
/32", 10mm)
(L=
Jamb
Sill
Sash
Window sash foam seal
(adhesive type)
Closure assembly
Open the window sash and place the air
conditioner on the sill.
3
Balance the unit on the sill and close the
window sash securely behind the top
angle.
WARNING:
At this step, make sure the unit is inclined
approximately 1 cm (
If the unit is not properly inclined, the water
collected in the bottom tray during operation will not drain properly and may flow into
the room where the air conditioner is installed.
Insert the bottom gasket into the space
between the window sill and the bottom of
4
the unit to seal outside air.
3
/8") to the back.
sill
unit
incline backwards approximately
1cm (3/8")
6
If there is space between the bottom
channel and the sill, fill the gap with a thin
board or other hard filler.
Bottom gasket
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.