In the interests of user-safety (Required by safety regulations in some countries) the set should
be restored to its original condition and only parts identical to those specified should be used.
This document has been published to be used
for after sales service only.
The contents are subject to change without notice.
Page 2
AFS120FX
AFS120FX
PREFACE
This SERVICE MANUAL provides various servicing information, including the mechanical and electrical parts, etc. This room air conditioner was
manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.
Service Manual
SAFETY PRECAUTIONS
1) When servicing the unit, set the POWER SWITCH to OFF and unplug the power cord.
2) Inspect the service cord for damage or wear.
If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit.
3) After servicing the unit, make an insulation resistance test to protect the customer from being exposed to shock hazards.
INSULATION RESISTANCE TEST
1) Unplug the power cord and connect a jumper lead between the two (2) live pins.
2) The grounding conductor (yellow/green) is to be open.
3) Measure the resistance value with an ohm meter between the jumped lead and each exposed metallic part on the equipment at all the positions
(except OFF) of the ROTARY SWITCH or POWER SWITCH.
4) The value should be over 1MΩ.
i
Page 3
AFS120FX
CHAPTER 1. PRODUCT SPECIFICATION
Service Manual
[1] SPECIFICATION
1. AF-S60FX
Cooling CapacityBTU/h6000
Moisture RemovalPint/h1.9
Electrical Data
PhaseSingle
Rared frequencyHz60
Rated voltageVolts115
Rated currentAmps4.9
Rated inputWatts560
Power factor%96
EERBTU/Wh10.7
Compressor
Type(Hermetically sealed rotary type)
Model, Motor Output39R141BD-04P, 570
REFRIGERANT SYSTEM
Evaporator Louver fin, Grooved tube, 7mm, hair pin
CondenserLouver fin, Grooved tube, 7mm, hair pin
Control O.D. x I.D x Length x Q'ty(mm) Capil-
lary Tube
Refrigerant Volume R-22 (OZ) Factory Charge 12.7
NET DIMENSIONS
Width Height DepthInch (mm)18.5" (470) x 12.6" (320) x 16.3" (415)
Net WeightLbs46.3
GROSS DIMENSIONS
Width Height DepthInch (mm)22.0" (560) x 14.8" (375) x 18.7" (472)
Gross WeightLbs57.3
FAN SYSTEM
Indoor side (Evaporator)Centrifugal fan
Outdoor side (Condenser)Propeller fan
Air Flow rate (Indoor side)CFMHigh / Med / Low
OTHERS
Safety devices Compressor: Over load
Air filterPolypropylene net
Power cord lengthft6.0
Power plug type125V, 15A
2.5 x 1.3 x 1000 x 1
500/440/386
Fan motor: Internal thermal protector
AFS120FX
1 – 1
Page 4
AFS120FX
2. AF-R80FX
Cooling CapacityBTU/h8000
Moisture RemovalPint/h2.1
Electrical Data
PhaseSingle
Rared frequencyHz60
Rated voltageVolts115
Rated currentAmps7.6
Rated inputWatts820
Power factor%96
EERBTU/Wh9.8
Compressor
Type(Hermetically sealed rotary type)
Model, Motor Output39R191CD-05s, 760
REFRIGERANT SYSTEM
Evaporator Louver fin, Grooved tube, 7mm, hair pin
CondenserLouver fin, Grooved tube, 7mm, hair pin
Control O.D. x I.D x Length x Q'ty(mm) Capillary Tube
Refrigerant Volume R-22 (OZ) Factory Charge 16.9
NET DIMENSIONS
Width Height DepthInch (mm)18.5" (470) x 12.6" (320) x 16.3" (415)
Net WeightLbs46.3
GROSS DIMENSIONS
Width Height DepthInch (mm)22.0" (560) x 14.8" (375) x 18.7" (472)
Gross WeightLbs50.7
FAN SYSTEM
Indoor side (Evaporator)Centrifugal fan
Outdoor side (Condenser)Propeller fan
Air Flow rate (Indoor side)CFMHigh / Med / Low
OTHERS
Safety devices Compressor: Over load
Air filterPolypropylene net
Power cord lengthft6.0
Power plug type125V, 15A
2.5 x 1.1 x 1000 x 2
700/630/560
Fan motor: Internal thermal protector
1 – 2
Page 5
3. AF-S80FX
Cooling CapacityBTU/h8000
Moisture RemovalPint/h2.1
Electrical Data
PhaseSingle
Rared frequencyHz60
Rated voltageVolts115
Rated currentAmps6.8
Rated inputWatts740
Power factor%94
EERBTU/Wh10.8
Compressor
Type(Hermetically sealed rotary type)
Model, Motor Output2R11S3R126A6B, 665
REFRIGERANT SYSTEM
Evaporator Louver fin, Grooved tube, 7mm, hair pin
CondenserLouver fin, Grooved tube, 7mm, hair pin
Control O.D. x I.D x Length x Q'ty(mm) Capillary Tube
Refrigerant Volume R-22 (OZ) Factory Charge 16.9
NET DIMENSIONS
Width Height DepthInch (mm)18.5" (470) x 12.6" (320) x 16.3" (415)
Net WeightLbs54.0
GROSS DIMENSIONS
Width Height DepthInch (mm)22.0" (560) x 14.8" (375) x 18.7" (472)
Gross WeightLbs61.7
FAN SYSTEM
Indoor side (Evaporator)Centrifugal fan
Outdoor side (Condenser)Propeller fan
Air Flow rate (Indoor side)CFMHigh / Med / Low
OTHERS
Safety devices Compressor: Over load
Air filterPolypropylene net
Power cord lengthft6.0
Power plug type125V, 15A
2.5 x 1.1 x 1000 x 2
700/630/560
Fan motor: Internal thermal protector
AFS120FX
1 – 3
Page 6
AFS120FX
4. AF-S85FX
Cooling CapacityBTU/h8000
Moisture RemovalPint/h2.1
Electrical Data
PhaseSingle
Rared frequencyHz60
Rated voltageVolts115
Rated currentAmps6.8
Rated inputWatts740
Power factor%94
EERBTU/Wh10.8
Compressor
Type(Hermetically sealed rotary type)
Model, Motor Output2R11S3R126A6B, 665
REFRIGERANT SYSTEM
Evaporator Louver fin, Grooved tube, 7mm, hair pin
CondenserLouver fin, Grooved tube, 7mm, hair pin
Control O.D. x I.D x Length x Q'ty(mm) Capillary Tube
Refrigerant Volume R-22 (OZ) Factory Charge 16.9
NET DIMENSIONS
Width Height DepthInch (mm)18.5" (470) x 12.6" (320) x 16.3" (415)
Net WeightLbs54.0
GROSS DIMENSIONS
Width Height DepthInch (mm)22.0" (560) x 14.8" (375) x 18.7" (472)
Gross WeightLbs61.7
FAN SYSTEM
Indoor side (Evaporator)Centrifugal fan
Outdoor side (Condenser)Propeller fan
Air Flow rate (Indoor side)CFMHigh / Med / Low
OTHERS
Safety devices Compressor: Over load
Air filterPolypropylene net
Power cord lengthft6.0
Power plug type125V, 15A
2.5 x 1.1 x 1000 x 2
700/630/560
Fan motor: Internal thermal protector
1 – 4
Page 7
5. AF-R100FX
Cooling CapacityBTU/h10000
Moisture RemovalPint/h2.5
Electrical Data
PhaseSingle
Rared frequencyHz60
Rated voltageVolts115
Rated currentAmps9.3
Rated inputWatts1020
Power factor%96
EERBTU/Wh9.8
Compressor
Type(Hermetically sealed rotary type)
Model, Motor Output44R241AG-FES, 950
REFRIGERANT SYSTEM
Evaporator Louver fin, Grooved tube, 7mm, hair pin
CondenserLouver fin, Grooved tube, 7mm, hair pin
Control O.D. x I.D x Length x Q'ty(mm) Capillary Tube
Refrigerant Volume R-22 (OZ) Factory Charge 19.4
NET DIMENSIONS
Width Height DepthInch (mm)18.9" (480) x 14.4" (365) x 22.6" (575)
Net WeightLbs72.7
GROSS DIMENSIONS
Width Height DepthInch (mm)22.1" (560) x 17.1" (435) x 24.6" (625)
Gross WeightLbs83.7
FAN SYSTEM
Indoor side (Evaporator)Centrifugal fan
Outdoor side (Condenser)Propeller fan
Air Flow rate (Indoor side)CFMHigh / Med / Low
OTHERS
Safety devices Compressor: Over load
Air filterPolypropylene net
Power cord lengthft6.0
Power plug type125V, 15A
2.5 x 1.3 x 1150 x 2
820/710/610
Fan motor: Internal thermal protector
AFS120FX
1 – 5
Page 8
AFS120FX
6. AF-S100FX
Cooling CapacityBTU/h10000
Moisture RemovalPint/h2.5
Electrical Data
PhaseSingle
Rared frequencyHz60
Rated voltageVolts115
Rated currentAmps8.4
Rated inputWatts920
Power factor%94
EERBTU/Wh10.8
Compressor
Type(Hermetically sealed rotary type)
Model, Motor Output2P14S126B1G, 855
REFRIGERANT SYSTEM
Evaporator Louver fin, Grooved tube, 7mm, hair pin
CondenserLouver fin, Grooved tube, 7mm, hair pin
Control O.D. x I.D x Length x Q'ty(mm) Capillary Tube
Refrigerant Volume R-22 (OZ) Factory Charge 19.4
NET DIMENSIONS
Width Height DepthInch (mm)18.9" (480) x 14.4" (365) x 22.6" (575)
Net WeightLbs77.1
GROSS DIMENSIONS
Width Height DepthInch (mm)22.1" (560) x 17.1" (435) x 24.6" (625)
Gross WeightLbs88.1
FAN SYSTEM
Indoor side (Evaporator)Centrifugal fan
Outdoor side (Condenser)Propeller fan
Air Flow rate (Indoor side)CFMHigh / Med / Low
OTHERS
Safety devices Compressor: Over load
Air filterPolypropylene net
Power cord lengthft6.0
Power plug type125V, 15A
2.5 x 1.3 x 1150 x 2
820/710/610
Fan motor: Internal thermal protector
1 – 6
Page 9
7. AF-R120FX
Cooling CapacityBTU/h12000
Moisture RemovalPint/h3.4
Electrical Data
PhaseSingle
Rared frequencyHz60
Rated voltageVolts115
Rated currentAmps11.1
Rated inputWatts1230
Power factor%95
EERBTU/Wh9.8
Compressor
Type(Hermetically sealed rotary type)
Model, Motor Output44R291AG-FES, 1075
REFRIGERANT SYSTEM
EvaporatorLouver fin, Grooved tube, 7mm, hair pin
CondenserLouver fin, Grooved tube, 7mm, hair pin
Control O.D. x I.D x Length x Q'ty(mm) Capillary Tube
Refrigerant Volume R-22 (OZ) Factory Charge 26.8
NET DIMENSIONS
Width Height DepthInch (mm)18.9" (480) x 14.4" (365) x 22.6" (575)
Net WeightLbs74.9
GROSS DIMENSIONS
Width Height DepthInch (mm)22.1" (560) x 17.1" (435) x 24.6" (625)
Gross WeightLbs85.9
FAN SYSTEM
Indoor side (Evaporator)Centrifugal fan
Outdoor side (Condenser)Propeller fan
Air Flow rate (Indoor side)CFMHigh / Med / Low
OTHERS
Safety devicesCompressor: Over load
Air filterPolypropylene net
Power cord lengthft6.0
Power plug type125V, 15A
2.5x1.1x800x1+2.5x1.1x1000x1+2.5x1.1x1050x2
820/710/610
Fan motor: Internal thermal protector
AFS120FX
1 – 7
Page 10
AFS120FX
8. AF-S120FX
Cooling CapacityBTU/h12000
Moisture RemovalPint/h3.4
Electrical Data
PhaseSingle
Rared frequencyHz60
Rated voltageVolts115
Rated currentAmps10.1
Rated inputWatts1110
Power factor%93
EERBTU/Wh10.8
Compressor
Type(Hermetically sealed rotary type)
Model, Motor OutputQK164CDB, 1054
REFRIGERANT SYSTEM
EvaporatorLouver fin, Grooved tube, 7mm, hair pin
CondenserLouver fin, Grooved tube, 7mm, hair pin
Control O.D. x I.D x Length x Q'ty(mm) Capillary Tube
Refrigerant Volume R-22 (OZ) Factory Charge 26.8
NET DIMENSIONS
Width Height DepthInch (mm)18.9" (480) x 14.4" (365) x 22.6" (575)
Net WeightLbs77.2
GROSS DIMENSIONS
Width Height DepthInch (mm)22.1" (560) x 17.1" (435) x 24.6" (625)
Gross WeightLbs88.2
FAN SYSTEM
Indoor side (Evaporator)Centrifugal fan
Outdoor side (Condenser)Propeller fan
Air Flow rate (Indoor side)CFMHigh / Med / Low
OTHERS
Safety devicesCompressor: Over load
Air filterPolypropylene net
Power cord lengthft6.0
Power plug type125V, 15A
2.5x1.1x800x1+2.5x1.1x1000x1+2.5x1.1x1050x3
820/710/610
Fan motor: Internal thermal protector
1 – 8
Page 11
9. AF-S125FX
Cooling CapacityBTU/h12000
Moisture RemovalPint/h3.4
Electrical Data
PhaseSingle
Rared frequencyHz60
Rated voltageVolts115
Rated currentAmps10.1
Rated inputWatts1110
Power factor%93
EERBTU/Wh10.8
Compressor
Type(Hermetically sealed rotary type)
Model, Motor OutputQK164CDB, 1054
REFRIGERANT SYSTEM
EvaporatorLouver fin, Grooved tube, 7mm, hair pin
CondenserLouver fin, Grooved tube, 7mm, hair pin
Control O.D. x I.D x Length x Q'ty(mm) Capillary Tube
Refrigerant Volume R-22 (OZ) Factory Charge 26.8
NET DIMENSIONS
Width Height DepthInch (mm)18.9" (480) x 14.4" (365) x 22.6" (575)
Net WeightLbs77.2
GROSS DIMENSIONS
Width Height DepthInch (mm)22.1" (560) x 17.1" (435) x 24.6" (625)
Gross WeightLbs88.2
FAN SYSTEM
Indoor side (Evaporator)Centrifugal fan
Outdoor side (Condenser)Propeller fan
Air Flow rate (Indoor side)CFMHigh / Med / Low
OTHERS
Safety devicesCompressor: Over load
Air filterPolypropylene net
Power cord lengthft6.0
Power plug type125V, 15A
The figure below is a brief description of the important components and their function in what is called the refrigeration system.
This will help to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle.
[2] TROUBLESHOOTING GUIDE
In general, possible trouble is classified in three kinds. One is called Starting Failure which is caused from an electrical defect, another is ineffective
Air Conditioning caused by a defect in the refrigeration circuit and improper application, and the other is called the Structure Damage.
ROOM AIRCONDITIONER VOLTAGE LIMITS:
NAMEPLATE RATINGMINIMUMMAXIMUM
115V103V122V
3 – 1
Page 17
1. Fail to start, Fail to start motor
AFS120FX
Press the PO WER but to n, then
thefan button on the Control
panel. Do th e lamp s li ght?
Check wiring.
Ch eck th e fa n ca pa citor.
Ch eck wh eth er the fan
is blocked.
Ch eck wh eth er the
blower is blocked.
Ch eck th e vo lta ge
between P1, P2, P3 on
ma in PCB and N o n
power cord.
Re pl ace the motor.
2. Abnormal noise
NoYes
Re pl ace the displ ay boa rd.
Any one of three no voltage
When tur ni ng the power on .
Yes
Is th er e a beep s ound from
the u nit?
No
Ch eck ci rcu it b re ake r
and fuse.
Check thepower cord.
Ch eck th e tr an sform er.
Re pl ace the fuse on mai n P CB.
Re pl ace the mai n PCB.
Ch eck whether the ai r- out
frame is vibrati ng or there is
so meth in g bloc k in g swi ng .
Check thepipe.
Ch eck whether the fan is
blocked.
Ch eck whether the bl owe r
is bl ocke d.
Re pl ace the motor.
Yes
Wh en op er ati ng in FAN
ONLY, is therestill same
noise?
Rechargerefrigerant.
Replace the capillary tube.
Ch eck whether the pi pes ar e
No
vib r ating or comi ng into
co ntact with other pi pe s or
compressor
Yes
Check whether the noise
is from in sid e t he pipe.
Check therubber isolator
under the compressor.
Re pl ace the compressor.
No
3 – 2
Page 18
AFS120FX
3. No/ineffective cooling
Ch eck wheth er the in do or
outl et/i nlet o f the un it is
blocked or the vent. door is
open.
Ch eck wheth er the ou tdoor
outl et or i nl et of the un it is
blocked.
Ch eck wheth er the ai r filte r
or Evap . or Con d. i s dirty.
Ch eck whet her the Evap. is
frosting and thecompressor
stops frequently.
Yes
Ch eck l ea kage.
Re cyc le refri ge rant a nd
braze the lea kage p oi nt.
Yes
No
Wh eth er the di splay panel
displa y one of the following
sig n al ?
""
No
Wh eth er the comp re ssor
ca n st a rt in cooling mode
even if it soon stops?
No
Re pl ace the main PCB.
Ch eck the sp ee d o f moto r.
Yes
No
voltage
indica tes r oom temp
se nsor failure.
indica tes i ndoor pipe
se nsor failure.
In di cate s the air f ilte r
needs to cle aning.
Ch eck tempe ratur e setting.
Check wiring.
Ch eck compr ess or
capacitor.
Check soft start module
(if fitted).
Ch eck the volta ge be tween
Compressorrelay on main
PCBand N on power cord.
Vacu um and rec harge.
Check the fancapacitor.
Repl ace the mot or.
PROBLEMPOSSIBLE CAUSEREMEDY
No display on panel or
any one of the buttons
failure.
Stop instantly after startup.
Fan motor will not run.Transformer (Discharge
Transformer (Discharge
transformer before testing)
Display board or main PCB
failure
Battery failureCheck the voltage of battery. Replace batteries if the voltage is lower than 2.3V.
RefrigerantThe amount of the refrigerant is too much, making the compressor load too big. Recy-
CompressorThe compressor is seized. Replace after checking for the reason.
transformer before testing)
No powerCheck voltage at electrical outlet. Correct if none.
Power supply cordCheck voltage at the power cord terminal on Main PCB. Replace the power cord if
Wire disconnected or connection loose
Main PCB failureSelect fan speed and Check the voltage on main PCB. Replace the main PCB if no
Capacitor (Discharge capacitor before testing)
Will not rotateFan blade hitting shroud or blower hitting scroll. Realign assembly. Check fan motor
Check resistance between the two input/output lines on transformer. Replace the
transformer if either of the input/output is open or the transformer is damaged.
Check the voltage of display board. Replace the display board if it is +5V else replace
the main PCB. Remote control failure.
cle and recharge the refrigerant after checking for the reason.
Check resistance between the two input/output lines on transformer. Replace the
transformer if either of the input/output is open or the transformer is damaged.
none.
Connect wire. Refer to wiring diagram for terminal identification. Repair or replace
loose terminal.
voltage in all three.
Test capacitor. Replace if not within +/-10% of manufacture's rating. Replace if
shorted, open or damaged.
bearings. Replace the motor if motor shaft do not rotate.
Re pl ace the compressor.
3 – 3
Page 19
AFS120FX
PROBLEMPOSSIBLE CAUSEREMEDY
Fan motor noise.FanReplace the fan if cracked, out of balance, or partially missing.
BlowerReplace the blower if cracked, out of balance, or partially missing.
Loose screwsTighten them.
Worn bearingsReplace the motor if knocking sounds continue when running or loose, or the motor
The compressor not to
stop even the room temperature has got to the
setting temperature.
Compressor will not run
while fan motor runs.
Insufficient cooling.Air filterClean or replace if restricted.
Excessive noise.Copper tubingRemove the cabinet and carefully rearrange tubing not to contact cabinet, compressor ,
The unit starts and stops
frequently.
No cooling.No powerCheck the voltage. Call an electrician if no within the limit.
Room temperature sensorCheck and replace if the temperature is open or damaged.
Main PCBCheck and replace the main PCB if the relay on PCB is shorted or damaged.
VoltageCheck voltage. Call Supply Authority if not within limits.
WiringCheck the wire connections, if loose, repair or replace the terminal. If wires are off,
Main PCB failureCheck voltage of main PCB. Replace the main PCB if open.
Capacitor (Discharge capaci-
tor before testing)
Room temp sensorCheck the temperature setting if not at the coolest (in cooling mode) or the warmest (in
CompressorCheck the compressor for open circuit or ground. If open or grounded, replace the
Vent. DoorClose if open.
Unit undersizedDetermine if the unit is properly sized for the area to be cooled or heated.
Condenser and EvaporatorClean or replace if restricted.
Fan motorCheck the fan capacitor and replace if not within +/-10% of manufactures rating.
Room structureTake proper measures to make the door and windows sealed well if gap is found.
Air flowClean or remove if any barrier is found to block the inlet/outlet wind flow of the unit.
SunlightAdd a awning if the condenser is exposed to the sunlight.
Less refrigerantCheck the tubes for reasons of leakage. Recycle the refrigerant, correct the leakage
Capillary tubeRegulate the flow if capillary tube and make the evaporating temperature appropriate if
CompressorThe inlet and outlet valve of the compressor is damaged, making the low pressure
Heat sourcesReduce if too many.
Power supplyThe input power supply voltage is too low. Call an electrician if not within limits.
Main PCBCheck and replace the main PCB if the relay on PCB is shorted or damaged.
Outdoor temperatureWhen the outdoor temperature is too high, the compressor will protect.
WiringCheck the terminals. Repair and correct if loose.
Temperature settingCheck and adjust the temperature setting.
Mode settingCheck and adjust the mode setting.
Main PCBCheck the voltage of main PCB. Replace the main PCB when the unit failure in heating
hums or noise appears to be internal while running.
refer to wiring diagram for identification, and replace. Check wire locations. If not per
wiring diagram, correct.
Check the capacitor. Replace if not within +/-10% of manufacturers rating. Replace if
shorted, open, or damaged.
heating mode). Set it if not.
compressor.
points and recharge.
the evaporator is frosted. Replace if blocked. Repair joint if leaking.
connected with the high pressure. The refrigerating system can not produce high pressure and low pressure. Replace the compressor after checking for the reason.
shroud and barrier.
mode.
3 – 4
Page 20
AFS120FX
— MEMO —
3 – 5
Page 21
REPLACEMENT PARTS LIST
Room Air Conditioner
AFS120FX
MODELS
CONTENTS
[1] Chassis Lower shutter frame
(Small)
[2] Electric control system Cabinet
and shutter Front panel ass'y
(Small)
[3] Airflow system Refrigerant
system (Small)
[4] Accessories (Small)
[5] Others (Small)
AF-S60FX
AF-R80FX
AF-S80FX
AF-S85FX
[7] Electric control system Cabinet
and shutter Front panel ass'y
(Medium)
[8] Airflow system Refrigerant
system (Medium)
[9] Accessories (Medium)
[10] Others (Medium)
INDEX
AF-R100FX
AF-S100FX
AF-R120FX
AF-S120FX
AF-S125FX
[6] Chassis Lower shutter frame
(Medium)
To have your order filled promptly and correctly, please furnish the
following information.
1. MODEL NUMBER 2. REF. No.
3. P ART NO. 4. DESCRIPTION
★ MARK: SPARE PARTS-DELIVERY SECTION
Parts marked with "" are important for maintaining the safety of the set. Be sure to replace these
parts with specified ones for
SHARP CORPORATION
“HOW TO ORDER REPLACEMENT PARTS”
For U.S.A. only
Contact your nearest SHARP Parts Distributor to order.
For location of SHARP Parts Distributor,
Please call Toll-Free;
1-800-BE-SHARP
This document has been published to be used
for after sales service only.
The contents are subject to change without notice.
8 LPLTMA216JBPZBRIn sta l lation board for e-parts
9 DPWBFA421JBKZBADisplay board
10 HPNLCA881JBFAAMControl box
10 HPNLCA880JBEAADdisplay panel
11 RH-HXA050JBZZAMEvaporator temp sensor
12 RH-HXA049JBZZAMIndoor temp sensor
16 LANGKA199JBFAADConnection bar to cabinet
17 GCAB-A301JBTABFCabinet
18 LANGKA198JBTAANUpper shutter frame
20 GWAKPA174JBFABCFront panel (included in 47)
21 PFILMA213JBEAAGAir filter (included in 47)
22 GWAK-A325JBFAAXPanel frame (included in 47)
23 MLOV-A422JBFAAQHorizontal louver (included in 47)
24 MLOV-A423JBFAADVertical louver A (included in 47)
24 MLOV-A424JBFAADVertical louver B (included in 47)
24 MJNTPA123JBFAADLouver link
7
Page 28
AFS120FX
[8] Airflow system Refrigerant system (Medium)
34
43
32
31
27
28
33
30
29
26
42
39
37
36
25
Air flow system
NO.PARTS CODE
PRICE
RANK
NEW
MARK
PART
RANK
[8] Airflow system Refrigerant system (Medium)
25 PKESSA101JBFZARLower fan shell
26 NFANSA048JBFAARCentrifugal fan
27 MLEVPA022JBFAADFresh air door
28 PKESSA102JBFZAPMed fan shell
29 PSEL-C855JBEZADWater proof rubberring
No part of this publication may be reproduced,
stored in retrieval systems, or transmitted in any
form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without
prior written permission of the publisher.
SHARP CORPORATION
Appliance Systems Group
Quality Assurance Department