ROOM AIR CONDITIONER
AF-A18CE
INSTALLATION AND OPERATION
MANUAL
КОМНАТНЫЙ КОНДИЦИОНЕР
РУКОВОДСТВО ПО УСТАНОВКЕ
И ЭКСПЛУАТАЦИИ
CONTENTS
PART NAMES AND DIMENSIONS ...... E-1
INSTALLATION INSTRUCTIONS ........ E-1
OPERATION INSTRUCTIONS ............. E-6
MODES OF OPERATION..................... E-7
CLEANING AND MAINTENANCE ....... E-9
BEFORE CALLING FOR SERVlCE ..... E-10
AF-A24CE
PAGE
ENGLISH
СОДЕРЖАНИЕ
НАИМЕНОВАНИЕ ЧАСТЕЙ
И РАЗМЕРЫ ........................................ R-1
ИНСТРУКЦИИ ПО УСТАНОВКЕ ....... R-1
ИНСТРУКЦИИ ПО ЭКСПЛУАТАЦИИ ...
РЕЖИМЫ РАБОТЫ ............................ R-7
ОЧИСТКА И УХОД.............................. R-9
ПРЕЖДЕ ЧЕМ ОБРАЩАТЬСЯ
В СЛУЖБУ СЕРВИСНОГО
ОБСЛУЖИВАНИЯ .............................. R-10
This INSTALLATION AND OPERATION MANUAL explains the proper use of your new SHARP Air
Conditioner. Read these instructions carefully before installing or operating your air conditioner. The
INSTALLATION AND OPERATION MANUAL should be kept in a safe place for handy reference.
В настоящем РУКОВОДСТВЕ ПО УСТАНОВКЕ И ЭКСПЛУАТАЦИИ объясняется, как правильно
пользоваться Вашим новым кондиционером SHARP. Пожалуйста, перед установкой и
эксплуатацией Вашего кондиционера внимательно прочтите эти инструкции. Это РУКОВОДСТВО
следует хранить в удобном месте для будущих консультаций.
СТРАНИЦА
R-6
РУССКИЙ
PART NAMES AND DIMENSIONS
1
B
DIMENSIONS
MODEL
A (mm)
B (mm)
C (mm)
D (mm)
E (mm)
2
A
AF-A18CE, AF-A24CE
4
3
5
D
660
425
729 (center 740)
294
40 (center 51)
Front panel
6
7
8
9
E
C
10
Grille
Air filter (behind the grille)
Up/Down air flow adjustment louvers
Left/Right air flow adjustment louvers
Cabinet
Ventilation lever
Control panel
Stopper screws
(on left and right)
Power cord
We reserve the right to change the materials and specifications without notice.
INSTALLATION INSTRUCTIONS
ITEMS PACKED WITH THIS UNIT
Accessories
GOLD SCREW (2.5cm/1")
GOLD SCREW (1.2cm/0.5")
DRAIN JOINT
BOTTOM GASKET
WRENCH
The long GOLD SCREW ( ) is used to secure the cabinet to the mounting frame.
The short GOLD SCREW( ) is used to secure the front panel to the unit.
The DRAIN JOINT ( ) is attached to the outlet on the back of the unit.
Cut off the blockage of the drain joint, if outside water drainage is necessary in high humidity
district, or if you do not prefer the splashing sound of the non-drain function.
See page E-3 for detail installation instructions.
Q'ty
8
1
1
1
1
ENGLISH
E-1
INSTALLATION INSTRUCTIONS
LOCATION
The appliance shall be installed in accordance with national wiring regulations.
Improper connection may cause the power cord and electrical outlet to overheat or fire.
Install the air conditioner to the opening dimensions shown below.
Never install the unit where any of the air inlet is blocked.
The air conditioner should be installed with a strong external support to minimize noise and
vibration, and for the purpose of safe installation, repair, replacement and secure positioning.
Avoid installing the air conditioner where it is exposed to direct sunlight.
43.5~44.5 cm
More than 40cm(16")
Air outlet
(17 1/8"~17 1/2")
More than 20 cm
(8")
More than 20cm(8")
67~68 cm
(26 3/8"
8~20 cm(3"~8")
~26 3/4"
More than 20 cm(8")
)
More than 40cm
(16")
Air inlet
More than 20cm(8")
Air inlet
Air inlet
Air outlet
Air inlet
POWER CABLING
GROUNDING
WARNING : THIS APPLIANCE MUST BE
GROUNDED.
Fit a disconnect switch, having a contact separation of
at least 3mm in all poles, to the electricity power line.
Connect the brown wire of the power supply cord to the
live terminal, and the grounding wire (green and yellow)
to the grounding terminal of the electrical outlet. The
remaining wire should be connected to the neutral
terminal of the electrical outlet.
FUSE
For safe, trouble free operation, connect the power
cord of the unit to a properly rated independent circuit
with a time delay fuse or a circuit breaker. See chart
for proper amp ratings for each model.
AF-A18CE
AF-A24CE
20 amp.
25 amp.
About 1cm
(3/8")
Grounding wire
(green&yellow)
Live
(brown)
Neutral
(blue)
Maximum Permissible
System Impedance
0.18 ( AF-A18CE )
0.13 ( AF-A24CE )
E-2