Sharp AU-X08CR, AY-X13CR, AY-X10CR, AE-X13CR, AE-X10CR Service Manual

...
1
AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR
S3214AYX13CR/
SPLIT TYPE
ROOM AIR CONDITIONERS
In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its original condition and only parts identical to those specified should be used.
SER VICE MANU AL
Page
SPECIFICATIONS ............................................................................................................................................. 2
EXTERNAL DIMENSIONS .................................................................................................................................4
WIRING DIAGRAMS ......................................................................................................................................... 6
ELECTRICAL PARTS.........................................................................................................................................9
BLOCK DIAGRAM ............................................................................................................................................10
MICROCOMPUTER CONTROL SYSTEM .......................................................................................................12
FUNCTIONS .................................................................................................................................................... 19
FUNCTION AND OPERATION OF PROTECTIVE PROCEDURES ............................................................... 25
BREAKDOWN DIAGNOSIS PROCEDURE .................................................................................................... 27
REFRIGERATION CYCLE ............................................................................................................................. 30
PERFORMANCE CURVES ............................................................................................................................. 32
DISASSEMBLING PROCEDURE.................................................................................................................... 33
OPTION ........................................................................................................................................................... 41
REPLACEMENT PARTS LIST ........................................................................................................................ 42
REFRIGERANT PIPING INSTALLATION/SERVICE MANUAL FOR AIR CONDITIONERS USING R-410A.. 49
TABLE OF CONTENTS
INDOOR UNIT
AH-X08CR/10CR/13CR AY-X08CR/10CR/13CR
OUTDOOR UNIT
AU-X08CR/10CR/13CR AE-X08CR/10CR/13CR
MODELS
SHARP CORPORATION
New Refrigerant : R-410A
2
AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR
SPECIFICATIONS
MODEL
I
NDOOR UNIT
OUTDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
ITEMS AH-X08CR AU-X08CR AH-X10CR AU-X10CR AH-X13CR AU-X13CR Cooling capacity
(Min. ~ Max.)
kW 2.2(0.9 _ 2.7) 2.8(0.9 _ 3.3) 3.6(0.9 _ 4.0)
Moisture removal Liters/h 0.6 0.7 1.3
Electrical data
Phase Single Rated frequency Hz 50 Rated voltage range V 198 to 264 Rated voltage V 220 - 240 Rated current A 3.4 _ 3.1 4.3 _ 4.0 5.5 _ 5.1 Rated input W 730 930 1200 Power factor % 98 _ 98 98
_
97 99 _ 98
Type Hermetically sealed rotary type
Compressor Model DA89X1F-20F
Oil charge Ester oil VG68 370ml Evaporator Bare tube type Grooved tube type Grooved tube type
Refrigerant system Condenser Louver Fin and Grooved tube type
Control Capillary tube Refrigerant volume
640g 690g 660g
(R-410A)
Noise level
High dB(A) 33 43 36 43 38 48
(at cooling)
Med. dB(A) 29 32 33 ­Low dB(A) 27 27 29 -
Fan system
Drive Direct drive Air flow quantity High m3/min. 7.5 28 8.7 28 9.3 30 (at cooling) Med. m3/min. 6.8 7.8 8.1
Low m3/min. 6.0 6.0 6.6
Fan
Cross flow fan Propeller fan Cross flow fan Propeller fan Cross flow fan Propeller fan
Connections
Refrigerant coupling Flare type Refrigerant tube size Gas, Liquid 3/8", 1/4" Drain piping mm O.D ø 18
Others
Compressor: Compressor thermistor
Safety device Fan motors: Thermal fuse
Fuse, Micro computer control
Air filters Polypropylene net (Washable)
Width mm 815 780 815 780 815 780
Net dimensions Height mm 278 540 278 540 278 540
Depth mm 198 269 198 269 198 269
Net weight kg 9 30 9 30 10 33 Note: The condition of star " " marked item are ‘ISO5151’ : 1994(E), condition T1.
3
AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR
MODEL
I
NDOOR UNIT
OUTDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
ITEMS AY-X08CR AE-X08CR AY-X10CR AE-X10CR AY-X13CR AE-X13CR Cooling capacity
(Min. ~ Max.)
kW 2.2(0.9 _ 2.7) 2.8(0.9 _ 3.3) 3.6(0.9 _ 4.0)
Heating capacity
(Min. ~ Max.)
kW 3.2(0.9 _ 3.6) 3.7(0.9 _ 5.0) 4.8(1.0 _ 6.2)
Moisture removal(at cooling) Liters/h 0.7 0.8 1.3
Electrical data
Phase Single Rated frequency Hz 50 Rated voltage range V 198 to 264 Rated voltage V 220 - 240
Cool A 3.4 _ 3.1 4.3 _ 4.0 5.5 _ 5.1
Rated current Heat A 4.2 _ 3.9 4.9 _ 4.5 6.8 _ 6.2
Cool W 730 930 1200
Rated input Heat W 910 1050 1480
Cool % 98 _ 98 98 _ 97 99 _ 98
Power factor Heat % 98 _ 97 97 _ 97 99 _ 99
Type Hermetically sealed rotary type
Compressor Model DA89X1F-20F
Oil charge Ester oil VG68 370ml Evaporator Louver Fin and Grooved tube type
Refrigerant system Condenser Corrugate Fin and Grooved tube type
Control Capillary tube Refrigerant volume
750g 770g 870g (R-410A) De-lce system Micro computer controled reversed systems
Noise level
High dB(A) 33 43 36 43 38 48
(at cooling)
Med. dB(A) 29 32 33 ­Low dB(A) 27 27 29 -
Fan system
Drive Direct drive Air flow quantity High m3/min. 7.5 28 9.8 27.7 9.3 30 (at cooling) Med. m3/min. 6.8 8.2 8.1
Low m3/min. 6.0 6.1 6.6
Fan
Cross flow fan Propeller fan Cross flow fan Propeller fan Cross flow fan Propeller fan
Connections
Refrigerant coupling Flare type Refrigerant tube size Gas, Liquid 3/8", 1/4" Drain piping mm O.D ø 18
Others
Compressor: Compressor thermistor
Safety device Fan motors: Thermal fuse
Fuse, Micro computer control
Air filters Polypropylene net (Washable)
Width mm 815 780 815 780 815 780
Net dimensions Height mm 278 540 278 540 278 540
Depth mm 198 269 198 269 198 269
Net weight kg 9 33 10 33 10 37 Note: The condition of star " " marked item are ‘ISO5151’ : 1994(E), condition T1.
4
AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR
EXTERNAL DIMENSIONS
Figure E-1. INDOOR UNIT
Figure E-2. OUTDOOR UNIT
Length unit (mm)
815
278
198
1100
Remote controller
58
18.5
22
140
INVERTER AIR CONDITIONER
269
179.5
182.5
136
81
780
70
540
310
335
540
12
37.5
4.5
58
158
16
5
AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR
Figure E-3. INSTALLATION DIMENSIONS
815 (unit size)
More than 50mm
E
Center of wall hole: Leftward piping
Center of wall hole: Backward piping
Outline of indoor unit
55 95
80 55
AJ
IF
E
D
D
FA
C
J
H
I
GB
21
278 (unit size)
38
Ceiling
E
Loading...