SHARP 32R-S50, 32R-S400, 36R-S50, 36R-S400 Service Manual

32R-S50, 32R-S400 36R-S50, 36R-S400
SERVICE MANUAL
COLOR TELEVISION
Chassis No. SN-92M
P
I
P
/
M
T
S
S
T
E
R
E
O
32R-S50, 32R-S400
MODELS
36R-S50, 36R-S400
In the interests of user-safety (Required by saf ety regulations in some countries ) the set should be restored to its original condition and only parts identical to those specified should be used.
CONTENTS
Page
» ELECTRICAL SPECIFICATIONS .........................................................................................................1
» IMPORTANT SERVICE SAFETY PRECAUTION ................................................................................. 2
» LOCATION OF USER'S CONTROL .....................................................................................................4
» INSTALLATION AND SERVICE INSTRUCTIONS ................................................................................6
» CHASSIS LAYOUT .............................................................................................................................12
» BLOCK DIAGRAM ..............................................................................................................................14
» SCHEMATIC DIAGRAMS ...................................................................................................................16
» PRINTED WIRING BOARD ASSEMBLIES ........................................................................................37
» REPLACEMENT PARTS LIST ............................................................................................................41
» PACKING OF THE SET ......................................................................................................................53
ELECTRICAL SPECIFICATIONS
POWER INPUT..................................................... 120V AC 60 Hz
POWER RATING
32R-S50/S400................................................................... 140W
36R-S50/S400................................................................... 165W
PICTURE SIZE
32R-S50/S400......................................... 3,073cm2 (476sq inch)
36R-S50/S400......................................... 3,905cm2 (605sq inch)
CONVERGENCE ............................................................. Magnetic
SWEEP DEFLECTION .................................................... Magnetic
FOCUS ............................................... Hi-Bi-Potential Electrostatic
INTERMEDIATE FREQUENCIES
Picture IF Carrier Frequency ..................................... 45.75 MHz
Sound IF Carrier Frequency...................................... 41.25 MHz
Color Sub-Carrier Frequency .................................... 42.17 MHz
(Nominal)
AUDIO POWER
OUTPUT RATING .............. 3.0W + 3.0W (at 10% distortion and
Dual CH Operate)
SPEAKER
SIZE ............................................................... 12 x 6 cm (2 pcs.)
VOICE COIL IMPEDANCE .............................. 6 ohm at 400 Hz
ANTENNA INPUT IMPEDANCE
VHF/UHF.....................................................75 ohm Unbalanced
TUNING RANGES
VHF-Channels...............................................................2 thru 13
UHF-Channels ............................................................ 14 thru 69
CATV Channels...........................................................1 thru 125
(EIA, Channel Plan U.S.A.)
Specifications are subject to change without prior notice.
SHARP CORPORATION
This document has been published to be used for after sales service only. The contents are subject to change without notice.
1
32R-S50, 32R-S400 36R-S50, 36R-S400
Ë
Service work should be performed only by qualified service technicians who are thoroughly familiar with all safety checks and the servicing guidelines which follow:
IMPORTANT SERVICE SAFETY PRECAUTION
WARNING
1. For continued safety, no modification of any circuit should be attempted.
2. Disconnect AC power before servicing.
3. Semiconductor heat sinks are potential shock hazards when the chassis is operating.
4. The chassis in this receiver has two ground systems which are separated by insulating material. The non­isolated (hot) ground system is for the B+ voltage regulator circuit and the horizontal output circuit. The isolated ground system is for the low B+ DC v oltages and the secondary circuit of the high voltage transformer. To prevent electrical shock use an isolation transformer between the line cord and power receptacle, when servicing this chassis.
CAUTION: FOR CONTINUED PROTECTION AGAINST A RISK OF FIRE, REPLACE
5A 125V
ONLY WITH SAME TYPE 5A­125V FUSE.
SERVICING OF HIGH VOLTAGE SYSTEM AND PICTURE TUBE
When servicing the high voltage system, remove the static charge by connecting a 10k ohm resistor in series with an insulated wire (such as a test probe) between the pic­ture tube ground and the anode lead. (AC line cord should be disconnected from AC outlet.)
1. Picture tube in this receiver employs integral implosion protection.
2. Replace with tube of the same type number for continued safety.
3. Do not lift picture tube by the neck.
4. Handle the picture tube only when wearing shatterproof goggles and after discharging the high voltage anode completely.
X-RADIATION AND HIGH VOLTA GE LIMITS
1. Be sure all service personnel are aware of the procedures and instructions covering X-radiation. The only potential source of X-ray in current solid state TV receivers is the picture tube. Howe ver , the picture tube does not emit measurable X-Ray radiation, if the high voltage is as specified in the "High Voltage Check" instructions. It is only when high voltage is excessive that X­radiation is capable of penetrating the shell of the picture tube including the lead in the glass material. The important precaution is to keep the high voltage below the maximum level specified.
2. It is essential that ser vicemen have available at all times an accurate high voltage meter. The calibration of this meter should be checked periodically.
3. High voltage should always be kept at the rated value
no higher. Operation at higher voltages may cause a failure of the picture tube or high voltage circuitry and;also, under certain conditions, may produce radiation in exceeding of desirable levels.
4. When the high voltage regulator is operating properly there is no possibility of an X-radiation problem. Every time a color chassis is serviced, the brightness should be tested while monitoring the high voltage with a meter to be certain that the high voltage does not exceed the specified value and that it is regulating correctly.
5. Do not use a picture tube other than that specified or make unrecommended circuit modifications to the high voltage circuitry.
6. When trouble shooting and taking test measurements on a receiver with excessiv e high voltage, av oid being unnecessarily close to the receiver. Do not operate the receiver longer than is necessary to locate the cause of excessive voltage.
2
2
2
2
IMPORTANT SERVICE SAFETY PRECAUTION
1.5k ohm 10W
0.15µF
TEST PROBE
TO EXPOSED METAL PARTS
CONNECT TO KNOWN EARTH GROUND
(Continued)
32R-S50, 32R-S400 36R-S50, 36R-S400
BEFORE RETURNING THE RECEIVER (Fire & Shock Hazard)
Before returning the receiver to the user, perform the following safety checks.
1. Inspect all lead dress to make certain that leads are not pinched or that hardware is not lodged between the chassis and other metal parts in the receiver.
2. Inspect all protective devices such as non-metallic control knobs, insulating materials, cabinet backs, adjustment and compartment covers or shields, isolation resistor-capacity networks, mechanical insulators, etc.
3. To be sure that no shock hazard exists, check for leakage current in the following manner.
Plug the AC cord directly into a 120 volt AC outlet, (Do not use an isolation transformer for this test).
Using two clip leads, connect a 1.5k ohm, 10 watt resistor paralleled by a 0.15µF capacitor in series with all exposed metal cabinet parts and a known earth ground, such as electrical conduit or electrical ground connected to earth ground.
Use an AC voltmeter ha ving with 5000 ohm per volt, or higher, sensitivity to measure the A C v oltage drop across the resistor.
Connect the resistor connection to all exposed metal parts having a return to the chassis (antenna, metal cabinet, screw heads, knobs and control shafts, escutcheon, etc.) and measure the AC voltage drop across the resistor. AII checks must be repeated with the AC line cord plug connection reversed. (If necessary, a non­polarized adapter plug must be used only for the purpose of completing these check.) Any current measured must not exceed 0.5 milliamp . Any measurements not within the limits outlined above indicate of a potential shock hazard and corrective action must be taken before returning the instrument to the customer.
234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121
234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121
SAFETY NOTICE
Many electrical and mechanical parts in television receivers have special safety-related characteristics. These characteristics are often not evident from visual inspection, nor can protection afforded by them be necessarily increased by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in this manual; electrical components having such features are identified by " å" and shaded areas in the Replacement Parts Lists and Schematic Diagrams.
234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121
For continued protection, replacement parts must be identical to those used in the original circuit. The use of substitute replacement parts which do not have the same safety characteristics as the factory recommended replacement parts shown in this service manual, may create shock, fire, X-radiation or other hazards.
3
32R-S50, 32R-S400 36R-S50, 36R-S400
Front Panel
LOCATION OF USER'S CONTROL
(32R-S50, 36R-S50)
POWER
Press On. Press again Off.
POWERCH– VOL +
VOLUME UP/DO WN
(+) Increases sound. (–) Decreases sound.
Basic Remote Control Functions
POWER
Press On. Press again Off.
REMOTE KEYPAD
Accesses any channel from keypad.
FLASHBACK
Returns to previous channel.
VOLUME UP/DOWN
(+) Increases sound. (–) Decreases sound.
• In menu mode, changes or selects the TV adjustments.
MUTE
Press Mutes sound. Press again Restores sound.
• CLOSED CAPTION appears when sound is muted.
POWERCH– VOL +
MENU
SENSOR AREA FOR REMOTE CONTROL
MENU
VIDEO/AUDIO TERMINALS
IN 2
(VIDEO/AUDIO terminals are also provided on the rear.)
CHANNEL UP/DOWN – MENU
'
( ) Selects next higher channel. ( ) Selects next lower channel.
"
• Press both at the same time to access the MAIN MENU screen.
Infrared Transmitter Window
INPUT
Press Switch to e xternal video input mode. Press again Switch to TV mode.
CHANNEL UP/DOWN
( ) Selects next higher channel.
'
( ) Selects next lower channel.
"
• Moves the “
” mark of the MENU
screen.
MENU
Press Accesses MAIN MENU. Press again → Exits MAIN MENU.
DISPLAY
Press Displa ys receiving channel for four seconds. Press again → Removes display.
• Temporarily displays receiving channel when in Closed Caption mode.
TV
4
LOCATION OF USER'S CONTROL (Continued)
(32R-S400, 36R-S400)
Front Panel
32R-S50, 32R-S400 36R-S50, 36R-S400
POWER
Press On. Press again Off.
POWERCH– VOL +
VOLUME UP/DO WN
(+) Increases sound. (–) Decreases sound.
Basic Remote Control Functions
POWER
Press On. Press again Off.
REMOTE KEYPAD
Accesses any channel from keypad.
FLASHBACK
Returns to previous channel.
PERSONAL PREFERENCE
With the Personal Preference buttons, you can program your favorite programs by using the 4 categories A, B, C and D. The channels can be accessed quickly by using these buttons.
VOLUME UP/DO WN
(+) Increases sound. (–) Decreases sound.
In menu mode, changes or selects the TV adjustments.
MENU
Press Accesses MAIN MENU. Press again → Exits MAIN MENU.
CATV/DVD-TV/VCR MODE SELECT SWITCH
In TV/VCR position, sends power and channel select commands (Channel up/down and Random Access buttons) to the TV and VCR control. In CATV/DVD position, sends power and channel select commands to a cable TV converter and DVD control.
DVD/VCR CONTROL
POWERCH– VOL +
MENU
SENSOR AREA FOR REMOTE CONTROL
POWER
TV
DVD VCR
DISPLAY
INPUT
1 2 3 4 5 6 7 8 9
FLASHBACK
PERSONAL PREFERENCE
A B C D
VOL
MENU MUTE
REW PLAY FF
PA USE
PIP
SWAP FREEZE MOVE SELECT
TV CA TV • VCR DVD
0
CH
CH
STOP REC
ENTER
100
VOL
+
CATV TV
DVD VCR
CH/SKIP
MENU
VIDEO/AUDIO TERMINALS
IN 2
(VIDEO/AUDIO terminals are also provided on the rear.)
CHANNEL UP/DOWN
'
( ) Selects next higher channel. ( ) Selects next lower channel.
"
Press both at the same time to access the MAIN MENU screen.
Infrared Transmitter Window
DISPLAY
Press Displa ys receiving channel for four seconds. Press again Removes display.
Temporarily displays receiving channel when in Closed Caption mode.
INPUT
Press Switch to external video INPUT 1 mode. Press 2 times Switch to external video INPUT 2 mode. Press 3 times Switch back to the original TV mode.
ENTER
Used in some instances where a Cable Converter Box requires an enter command after selecting channels, when using the REMOTE KEYPAD button.
CHANNEL UP/DOWN
'
( ) Selects next higher channel. ( ) Selects next lower channel.
"
Moves the
mark of the MENU
screens.
MUTE
Press Mutes sound. Press again → Restores sound.
CLOSED CAPTION appears when sound is muted.
PIP FUNCTION
With the VIDEO inputs, you can watch two pictures at the same time.
Note:
The above shaded buttons on the Remote Control glow in the dark. To use the glow-in-the-dark display on the remote control, place it under a fluorescent light or other lighting.
The phosphorescent material contains no radioactive or toxic material, so it is safe to use.
The degree of illumination will vary depending on the strength of lighting used.
The degree of illumination will decrease with time and depending on the temperature.
The time needed to charge the phosphorescent display will vary depending on the surrounding lighting.
Sunlight and fluorescent lighting are the most effective when charging the display.
5
32R-S50, 32R-S400 36R-S50, 36R-S400
INSTALLATION AND SERVICE INSTRUCTIONS
Note: (1)When performing any adjustments to resistor controls and transformers use non-metallic
screwdrivers or TV alignment tools.
(2)Before performing adjustments, the TV set must be on at least 15 minutes.
CIRCUIT PROTECTION
The receiver is protected by a 5.0A fuse (F701), mounted on PWB-A, wired into one side of the AC line input.
X-RADIATION PROTECTOR CIRCUIT TEST
After service has been performed on the horizontal deflection system, high voltage system, B+ system, test the X-Radiation protection circuit to ascertain proper operation as follows:
1. Apply 120V AC using a variac transformer for accurate input voltage.
2. Allow for warm up and adjust all customer controls for normal picture and sound.
3. Receive a good local channel.
4. Connect a digital voltmeter to TP653 and make sure that the voltmeter reads 13.8 ±0.7V (32R-S50, 32R­S400)/13.2 ± 0.7V(36R-S50, 36R-S400).
5. Apply external 17.0V DC (32R-S50, 32R-S400)/
16.2V DC (36R-S50, 36R-S400) at TP653 by using an external DC supply, TV must be shut off.
6. To reset the protector, unplug the AC cord and plug the AC cord power on. Now make sure that normal picture appears on the screen.
7. If the operation of the horizontal oscillator does not stop in step 5, the circuit must be repaired before the set is returned to the customer.
HIGH VOLTAGE CHECK
High voltage is not adjustable but must be checked to verify that the receiver is operating within safe and efficient design limitations as specified checks should be as follows:
1. Connect an accurate high voltage meter between ground and anode of picture tube.
2. Operate receiver for at least 15 minutes at 120V AC line voltage, with a strong air signal or a properly tuned in test signal.
3. Enter the service mode and select the service adjustment "S19" and Bus data "01" (Y-mute on).
4. The voltage should be approximately 32.8kV(32R­S50, 32R-S400)/33.4kV(36R-S50, 36R-S400) (at zero beam). If a correct reading cannot be obtained, check circuitry for malfunctioning components. After the voltage test, make Y-mute off to the normal mode.
6
32R-S50, 32R-S400 36R-S50, 36R-S400
For adjustments of this model, the bus data is conver ted to various analog signals by the D/A converter circuit.
Note: There are still a few analog adjustments in this series such as focus and master screen voltage.
Follow the steps below whenever the service adjustment is required. See "Table-B" to determine, if serv­ice adjustments are required.
1. Service mode
Before putting unit into the service mode, check that customer adjustments are in the normal mode. Use the reset function in the video adjustment menu to ensure customer controls are in their proper (reset) position.
2. Service number selection
Once in the service mode, press the Ch-up or Ch­down button on the remote controller or at the set. The service adjustment number will vary in increments of one, from "S01" to "P07". Select the item you wish to adjust.
3. Data number selection
Press the V ol-up or v ol-down button to adjust the data number.
DATA NUMBER
SERVICE ADJUSTMENT NUMBER
To enter the ser vice mode and exit serv­ice mode.
While pressing the V ol-up and Ch-up b uttons at the same time, plug the AC cord into a wall socket. Now the TV set is switched on and enters the service mode. To exit the service mode, turn the television off by pressing the power button.
CHANNEL
S01
Figure A.
55(085)
02
7
32R-S50, 32R-S400 36R-S50, 36R-S400
SERVICE
NUMBER
S01 PICTURE 5E 00-7F S02 TINT 46 00-7F S03 COLOUR 32 00-7F S04 BRIGHTNESS 40 00-7F S05 SHARPNESS 28 00-3F Must be set to "24" S06 Vert. PHASE 00 00-07 Must be set to "00" S07 Hor. PHASE 12 00-1F S08 RF AGC 23 00-3F S09 Vert. AMPLITUDE 20 00-3F S10 PIF VCO 2C 00-7F S11 R CUT-OFF 00 00-FF S12 G CUT -OFF 00 00-FF S13 B CUT-OFF 00 00-FF S14 G GAIN 7F 00-FF S15 B GAIN 7F 00-FF S16 TRAP 00 00,01 Must be set to "01" S17 4B 00-3F S18 CC POSITION 17 00-FF S19 MUTE 00 00,01,03 S20 ENERGY SAVE OFFSET 20 00-3F Must be set to "23" S21 PERIOD ADJ. 7A 00-FF Must be set to "7A" S22 F AO V OLUME STEP 25 00-32 S23 TUNER 00 00,01 Must be set to "00" S24 FAV. COLOR RTONE-G F9 00-FF S25 FAV. COLOR RTONE-B EB 00-FF S26 FAV. COLOR BTONE-G 02 00-FF S27 FAV. COLOR BTONE-B 08 00-FF S28 COLOR TEMP LOW-G E1 00-FF S29 COLOR TEMP LOW-B AE 00-FF S30 COLOR TEMP ML-G F A 00-FF S31 COLOR TEMP ML-B E7 00-FF S32 COLOR TEMP HIGH-G 08 00-FF S33 COLOR TEMP HIGH-B 14 00-FF OP1 OPTION1 00 00-FF Must be set to "B1" for 32R-S50/36R-S50
OP2 OPTION2 00 00-FF Must be set to "C7" for 32R-S50/36R-S50 M01 INPUT LEVEL 0A 00-0F
M02 ST VCO 20 00-3F M03 FILTER 1C 00-3F M04 WIDE BAND 20 00-3F M05 SPECTRAL 1B 00-3F P01 PIP Y -LEVEL 30 00-7F P02 PIP TINT 29 00-3F Must be set to "29" for 32R-S400/36R-S400 P03 PIP COLOR 2E 00-7F P04 PIP Y-OFFSET 09 00-1F Must be set to "09" for 32R-S400/36R-S400 P05 PIP H-POSITION 0A 00-FF Must be set to "0A" for 32R-S400/36R-S400 P06 PIP BGPM 00 00-0F Must be set to "00" for 32R-S400/36R-S400 P07 PIP FREERUN 0B 00-0F Must be set to "0B" for 32R-S400/36R-S400
ADJUSTMENT ITEM
INITIAL V ALUE
DA T A
ADJUSTMENT CONTENTS
RANGE
"00" : NORMAL, "01" : Y-MUTE, "03" : V-STOP & Y-MUTE
Must be set to "B7" for 32R-S400/36R-S400 Must be set to "E7" for 32R-S400/36R-S400
Table - A
Holding down both the VOL-up/CH-down buttons on the TV set at service mode for more than 2 seconds will automatically write the above initial values into IC2101.
PART REPLACED
IC2001 IC201
IC2101
CRT IC3001
IC1801
NECESSARY UNNECESSARY
ADJUSTMENT
X
X
X X X
NOTES
X
Data is stored in IC2101. The adjustment is needed to compensate for characteristics of parts
including IC201 and MTS level (M01). Holding down both the V OL-up/CH-down buttons on the TV set in the
service mode for more than 2 seconds will automatically write the above initial values into IC2101. Then perform a complete adjustment.
Adjust items related to picture tube only. Adjust items related to MTS only (M01~M05).
Adjust items related to P-IN-P only (P01~P07).
Table - B
8
Ë
SERVICE ADJUSTMENT
32R-S50, 32R-S400 36R-S50, 36R-S400
VCO Adjustment
1. Connect a digital voltmeter between pin (44) of IC201 and ground.
2. Receive a good local channel.
3. Enter the service mode and select the service adjustment "S10".
4. Adjust the data so that digital voltmeter reads 2.2V.
5. Adjustment is completed, remove the voltmeter, return to "normal" mode.
RF AGC Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "S08".
3. Set the data value to point where no noise or beat appears.
4. Select another channel to confirm that no noise or beat appears. Note 1 : You will have to come out of the service
mode to select another channel.
Note 2 : Setting the data to "00" will produce a black
raster.
White Balance Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "S03" and set to "00" (minimum color)(Record original data code under adjustment "S03" before changing). "S03" does not have to be adjusted, if you selected a B/W picture or monoscope pattern.
3. Alternately adjust the ser vice adjustment data of "S14" and "S15" until a good grey scale with normal whites is obtained.
4. Select the service adjustment "S03" and adjust data to obtain normal color level.
Sub-Picture Adjustment
1. Receive a good local channel.
2. Make sure the customer picture control is set to maximum.
3. Enter the service mode and select the service adjustment "S01".
4. Adjust the data value to achieve normal contrast range.
Screen Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "S03" and set the data value to "00" to set the color level to minimum. (Record original data code under adjustment "S03" before changing) You may skip this step, if you selected a B/W picture or monoscope pattern.
3. Select the service adjustment "S19" and adjust the data value to "01", this turn off the luminance signal (Y-mute).
4. Select the service adjustment "S04" and adjust data value to "4B".
5. Adjust the master screen control until the raster darkens to the point where raster is barely seen.
6. Adjust the service adjustments "S11" red, "S12" green and "S13" blue to obtain a good grey scale with normal whites at low brightness level.
7. Select the service adjustment "S19" and reset data to "00". Select the service adjustment "S03" and reset data to obtain normal color level.
8. Reset the master screen control to obtain normal brightness range.
Sub-Tint Adjustment
1. Receive a good local channel.
2. Set customer tint control to center of it's range.
3. Enter the service mode and select the service adjustment "S02".
4. Adjust "S02" data value to obtain normal flesh tones.
Sub-Color Adjustment
1. Receive a good local channel.
2. Make sure the customer color control is set to center position .
3. Enter the service mode and select service adjustment "S03".
4. Adjust "S03" data value to obtain normal color level.
Sub-Brightness Adjustment
1. Receive a good local channel.
2. Make sure the customer brightness control is set to center position.
3. Enter the service mode and select the service adjustment "S04".
4. Adjust "S04" data value to obtain normal br ightness level.
9
32R-S50, 32R-S400 36R-S50, 36R-S400
Vertical-Size and Linearity Adjustments
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "S09".
3. While obser ving the top and bottom of the screen, adjust "S09" data value to proper vertical size.
4. Using the R502 control adjust for the best linearity.
Vertical Phase Adjustment
1. Enter the service mode and select the service adjustment "S06".
2. Adjust data value to "00". Note: This must be set "00" when changed data
retrace line will appear .
Horizontal Position Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "S07".
3. Adjust "S07" data value so that picture is centered.
Caption Position Adjustment (Horizontal)
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "S18".
3. A black text box appears on the screen. (see
B.
below)
4. Adjust "S18" data value so that text box is positioned in the center of the screen.
Figure
3.58MHz T rap Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "S16".
3. This is a two position adjustment, "00" is ON, "01" is OFF.
4. Adjust data value to "01" for normal viewing.
Sharpness and Audio Balance Adjustments
1. Receive a good local channel.
2. Enter the service mode and select the service adjustments "S05" for sharpness and "S17" for audio balance.
» Sharpness Adjustment
3. Adjust data value to "24"(center of data range) for sharpness adjustment.
» Audio Balance Adjustment
4. Adjust data value to "20"(center of data range) for Audio balance adjustment.
Vertical Center Adjustment
1. Receive a good CATV channel.
2. Adjust the S502 so that the picture is centered.
Side Pincushion Adjustment
1. Receive a good CA TV channel or crosshatch pattern signal.
2. Adjust the R676 so that the outer most line on the screen is straight.
Horizontal Size Adjustment
1. Receive a good CA TV channel or crosshatch pattern signal.
2. Adjust the R678 so that the best horizontal size.
Energy Save Offset Adjustment
1. Enter the service mode and select the service adjustment "S20".
2. Adjust data value to "23".
Note : This position is used to preset the level for the
energy save function.
Other Adjustments
1. Enter the service mode.
2. Adjust the following data values as listed below.
SERVICE ADJUST DATA
POSITION ITEM
S05 SHARPNESS 24 S06 V-PHASE 00 S16 TRAP 01 S20 E-SAVE 23 S21 TIMER 7A S23 TUNER SETUP 00 S22 FAO 25 S28 COL. TEMP. LOW -G E1 S29 COL. TEMP. LOW-B AE S30 COL. TEMP. ML-G F A S31 COL. TEMP. ML-B E7 S32 COL. TEMP. ML-B 08 S33 COL. TEMP. HIGH-G 14
(Hex)
Figure B.
SERVICE 32R-S50, 32R-S400,
POSITION 36R-S50 36R-S400
OP1 B1 B7 OP2 C7 E7
10
32R-S50, 32R-S400 36R-S50, 36R-S400
Ë
MTS ADJUSTMENT
MTS Level Adjustment
1. Feed the following monaural signal to pin (14) of IC3001.
Monaural signal : 300Hz, 245mVrms
2. Connect the rms voltmeter to pin (39) of IC3001.
3. Enter the service mode and select the service adjustment "M01".
4. Adjust the data so that the rms voltmeter reads 490 ±10 mVrms.
MTS VCO Adjustment
1. Keep the unit in no-signal state.
2. Connect the frequency counter to pin (39) of IC3001.
3. Connect a capacitor (100µF, 50V) in between positive(+) side of C3005 and ground.
4. Enter the service mode and select the service adjustment "M02"
5. Adjust the data so that the frequency counter reads
62.94 ±0.75kHz.
Filter Adjustment
1. Feed the following stereo pilot signal to pin (14) of IC3001 . Stereo pilot signal: 9.4kHz, 600mVrms.
2. Enter the service mode and select the service adjustment "M03".
3. Adjust the data until "OK" appears in position on the screen. Make sure the "OK" is displayed almost at the center of the data range.
Separation Adjustment
1. Connect the rms voltmeter to pin (39) of IC3001.
2. Receive the following composite stereo signal 1. Composite stereo signal: 30% modulation, left channel only, noise reduction on, 300Hz
3. Enter the service mode and select the service adjustment "M04".
4. Adjust the data until the AC voltage reading of the RMS voltmeter is minimum.
5. Receive the following composite stereo signal 2. Stereo signal: 30% modulation, left channel only, noise reduction on, 3kHz
6. Enter the service mode and select the service adjustment "M05".
7. Adjust the data until the AC voltage reading of the RMS voltmeter is minimum.
8. Take the above steps 1 thru 7 again for fine adjustment.
Ë
P-IN-P ADJUSTMENT
(Only for 32R-S400, 36R-S400)
P-IN-P Y-LEVEL Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "P01".
3. Adjust "P01" data value to obtain normal contrast level.
P-IN-P TINT Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "P02".
3. Adjust data value to "29".
P-IN-P COLOR Adjustment
1. Receive a good local channel.
2. Make sure the customer color control is set to center position.
3. Enter the service mode and select service adjustment "P03".
4. Adjust "P03" data value to obtain normal color level.
P-IN-P Y-OFF SET Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "P04".
3. Adjust data value to "09".
P-IN-P H-POSITION Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "P05".
3. Adjust data value to "0A".
P-IN-P BURST GATE PULSE (for MAIN)
1. Receive a good local channel.
2. Enter the service mode and select the service adjustment "P06".
3. Adjust data value to "00".
P-IN-P FREERUN
1. Receive a good local channel.
2. Enter the service mode and select service adjustment "P07".
3. Adjust data value to "0B".
11
32R-S50, 32R-S400 36R-S50, 36R-S400
MODELS 32R-S50, 36R-S50 CHASSIS LAYOUT
H
G
F
E
D
C
B
A
654321
12
MODELS 32R-S400, 36R-S400 CHASSIS LAYOUT
H
G
F
32R-S50, 32R-S400 36R-S50, 36R-S400
E
D
C
B
A
654321
13
32R-S50, 32R-S400 36R-S50, 36R-S400
MODELS 32R-S50, 36R-S50 BLOCK DIAGRAM
H
G
F
E
D
C
B
A
654321
14
Loading...
+ 31 hidden pages