Shark ION F80 Cord-Free MultiFLEX UF280 Series, ION F80 Cord-Free MultiFLEX IF280 Series Owner's Manual

TM/MC
ION
Cord-Free MultiFLEX Sans Cordon, MultiFLEX Sin Cable, MultiFLEX
Série/Serie
TM
MC
MC
IF280/UF280
Series
OWNER'S GUIDE GUIDE D’UTILISATION MANUAL DEL PROPIETARIO
IMPORTANT SAFETY INSTRUCTIONS
FOR HOUSEHOLD USE ONLY • PLEASE READ CAREFULLY BEFORE USE If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit,
contact a qualified electrician. DO NOT force into outlet or try to modify to fit.
WARNING
To reduce the risk of fire, electric shock, injury, or property damage:
THE DUOCLEAN® FLOOR NOZZLE, WAND, AND HANDVAC CONTAIN ELECTRICAL CONNECTIONS:
1. This vacuum consists of a motorized nozzle,
wand, and handvac. These components contain electrical connections, electrical wiring, and
QUICK
moving parts that potentially present risk to the us er.
2. Before each use, carefully inspect all parts for
START
any damage. If a part is damaged, discontinue use.
GUIDE
3. Use only identical replacement parts.
4. This vacuum contains no serviceable parts.
5. Use only as described in this manual. DO NOT use the vacuum for any purpose other
than those described in this manual.
6. With the exception of filters, DO NOT expose any parts of the vacuum to water or other liquids.
GENERAL USE
7. This vacuum is not intended for use by anyone
with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the vacuum.
8. Always turn o the vacuum before connecting or disconnecting any current carrying hoses, motorized nozzles, chargers, batteries, or other electrical or mechanical parts.
9. DO NOT handle plug or vacuum with wet hands.
10. DO NOT use without dust cup, filters, and brushrolls in place.
11. Only use Shark® branded filters and accessories. Failure to do so will void the warranty.
12. DO NOT put any objects into nozzle or accessory openings. DO NOT use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce airflow.
13. DO NOT use if nozzle or accessory airflow is restricted. If the air paths or the motorized floor nozzle become blocked, turn the vacuum o and remove the battery. Remove all obstructions before you reinsert the battery and turn on the unit again.
14. Keep nozzle and all vacuum openings away from hair, face, fingers, uncovered feet, or loose clothing.
15. DO NOT use if vacuum is not working as it should, or has been dropped, damaged, left outdoors, or dropped into water.
16. Use extra care when cleaning on stairs.
17. DO NOT leave the vacuum unattended while
powered on.
18. When powered on, keep the vacuum moving over the carpet surface at all times to avoid damaging the carpet fibers.
19. DO NOT place vacuum on unstable surfaces such as chairs or tables.
20. DO NOT use to pick up:
a) Liquids b) Large objects c) Hard or sharp objects (glass, nails, screws,
or coins)
d) Large quantities of dust (including drywall,
fireplace ash, or embers). DO NOT use as an attachment to power tools for dust collection.
e) Smoking or burning objects (hot coals,
cigarette butts, or matches)
f) Flammable or combustible materials (lighter
fluid, gasoline, or kerosene)
g) Toxic materials (chlorine bleach, ammonia,
or drain cleaner)
21. DO NOT use in the following areas: a) Poorly lit areas b) Wet or damp surfaces c) Outdoor areas d) Spaces that are enclosed and may contain
explosive or toxic fumes or vapors (lighter fluid, gasoline, kerosene, paint, paint thinners, mothproofing substances, or flammable dust)
22. Turn o the vacuum before inserting or
removing the battery, as well as before plugging in or unplugging the charger.
23. Turn o the vacuum and remove the battery
before any adjustment, cleaning, maintenance or troubleshooting.
24. During cleaning or routine maintenance, DO NOT cut anything other than hair, fibers, or
string wrapped around the brushroll.
25. Allow all filters to air-dry completely before replacing in the vacuum to prevent liquid from being drawn into electric parts.
26. DO NOT modify or attempt to repair the vacuum or the battery yourself, except as indicated in this manual. DO NOT use the battery or vacuum if it has been modified or damaged.
BAT TERY PACK
27. The battery is the power source for the
vacuum. Carefully read and follow all charging instructions.
28. To prevent unintentional starting, ensure the vacuum is powered o before picking up or carrying the vacuum. DO NOT carry the appliance with your finger on the power switch.
®
29. Use only Shark
or YLS0483A-T2880802. Use of incorrect charger may create a risk of fire when used with ION Power Pack Battery XBAT200.
30. Keep the battery away from all metal objects
such as paper clips, coins, keys, nails, or screws. Shorting the battery terminals increases the risk of fire or burns.
31. Under abusive conditions, liquid may be
ejected from the battery. Avoid contact with this liquid, as it may cause irritation or burns. If contact occurs, flush with water. If liquid contacts eyes, seek medical help.
32. Battery should not be stored at temperatures
below 37.4°F (3°C) or above 104°F (40°C) to maintain long-term battery life.
33. DO NOT charge battery at temperatures
below 50°F (10°C) or above 104°F (40°C).
34. Store the appliance indoors. DO NOT use
or store it below 37.4°F (3°C). Ensure the appliance is at room temperature before operating.
35. DO NOT expose the battery to fire or
temperatures above 265°F (130°C) as it may cause explosion.
chargers YLS0243A-T288080
SAVE THESE INSTRUCTIONS
sharkclean.comsharkclean.com
3
(Click)
ASSEMBLY
YOUR ION POWER PACK BATTERY
Your ION Power Pack Battery does not come fully charged. Prior to first use, charge completely. During first
use, discharge fully to condition your ION Power Pack Battery. Failure to do so may cause LED indications to work incorrectly.
RECYCLING THE ION POWER PACK BATTERY
When your ION Power Pack Battery needs to be replaced, dispose of it or recycle it in accordance with local ordinances or regulations. In some areas, it is illegal to place spent lithium-ion batteries in the trash or in a municipal solid waste stream. Return spent power packs to an authorized recycling center or to retailer for recycling. Contact your local recycling center for information on where to drop o the spentpower pack.
RUNTIMES PER FULLY-CHARGED BATTERY
MODE AND SETTINGS ION POWER ION BOOST
HANDVAC ONLY Up to 40 Minutes Up to 12 Minutes
BARE FLOOR (Wand/Nozzle Connected) Up to 32 Minutes Up to 11 Minutes
CARPET (Wand/Nozzle Connected) Up to 26 Minutes Up to 10 Minutes
NOTE: See enclosed Quick Start Guide for number of ION Power Pack batteries included with your vacuum.
LED BATTERY POWER AND CHARGING INDICATORS
2
(Click)
1
(Click)
1. Insert wand into floor nozzle.
2. Insert handheld vacuum into wand.
3. Insert battery into handheld vacuum.
For proper operation, ensure all components are firmly connected.
NOTE: A complete charge takes approximately 3.5 hours. The ION Power Pack, like all lithium-ion products, will naturally decrease in capacity over time from the 100% capacity of a new battery.
sharkclean.com sharkclean.com
Charging
Low Charge
Nearly Full
NOTE: Full charge takes approximately 3.5 hours.
Mid Charge
Full Charge
In Use
Full Charge
Nearly Empty
Mid Charge
No Charge
Low Charge
CHARGING THE ION POWER PACK BATTERY
ION
SMART RESPONSE™ TECHNOLOGY
USING THE ION POWER PACK CHARGER
OR
OUT OF THE VACUUMIN THE VACUUM
USING THE ION POWER PACK CHARGING DOCK
Surface Settings Power Button Suction Settings
CARPET
For carpets.
FLOOR
For bare floors and small area rugs.
21
ION POWER
For everyday cleaning.
ION BOOST
1-minute boost of increased
Press for a timed
suction for high-trac
areas and heavy messes.
To use ION BOOST
mode for longer
than 1-minute, you
can re-press the
ION BOOST
button when the
1-minute period ends.
You can end
ION BOOST
mode prior to
the 1-minute
by pressing the
ION BOOST button.
Press and
hold ION BOOST
for manual control of the mode for as
long as you need it.
Connect ION Power Pack Battery Charger to the Charging Dock by inserting the charger plug into the port. Turn plug clockwise to lock.
NOTE: Not all units come with the charging dock. See enclosed Quick Start Guide for your configuration.
Place battery onto dock, then connect charger to wall outlet.
PLEASE NOTE: Use of ION BOOST Mode will drain your ION Power Pack faster. NOTE: Select Carpet setting for stuck-on dirt and debris. NOTE: For deep cleaning pe r ASTM F 608 (embed ded dir t in carpets) please selec t CARPET and ION BOOST settings.
sharkclean.comsharkclean.com
VERSATILE CLEANING
USING THE MULTIFLEXTM WAND
FLOOR MULTIFLEX REACHABOVE FLOOR MULTIFLEX STORAGE
Wand
Release
(Click)
Press the Power button, then choose your Surface setting and your Suction setting. Place your foot gently on the floor nozzle and tilt the handle back.
For low furniture, take advantage of the MultiFlex™ wand. See next page.
NOTE: Brushrolls will only engage when the handle is tilted back.
Press the Wand Release button to disconnect the handheld vacuum. Attach accessory, then press the power button.
Stand the vacuum upright. Step on the Floor Nozzle Release pedal and pull the wand up to disconnect it
from the floor nozzle. Attach accessory, then press the power button.
Press the MultiFLEX Wand button to position the wand to a lower angle for ease of use under low furniture.
Press the MultiFLEX Wand button and hold it down while folding the handheld vacuum forward. Use the handle to carry the vacuum.
(Click)
To take the vacuum out of storage mode, press the MultiFlex up the handheld vacuum.
TM
Wand button while lifting
NOTE: All accessories are compatible with both the handvac and the wand.
sharkclean.comsharkclean.com
MAINTAINING YOUR VACUUM
MAINTAINING YOUR VACUUM
EMPTYING THE DUSTCUP
Wand
Release
Disconnect the hand vacuum from the wand.
2
CLEANING THE FILTERS
To clean filters, rinse with water only to prevent damage from cleaning chemicals. Allow all filters to air-dry completely for at least 24 hours before replacing them in the vacuum to prevent liquid from being drawn
1
into electricparts.
IMPORTANT: DO NOT use soap when cleaning the filters.
FILTER COVER
FILTER
PRE-MOTOR
FILTER
FRAME
POST-MOTOR
FILTER
PRE-MOTOR FILTER POST-MOTOR FILTER
Remove cover and frame. Slide filter o frame. Rinse with water. Air-dry completely for at least 24 hours before reinserting. Tap o loose dirt between washes as needed.
Remove cover and filter. Rinse filter with water. Air-dry completely for at least 24 hours before reinserting. Tap o loose dirt between washes as needed.
FILTER COVER
Press the dust cup Empty button.
NOTE: To order filters and other parts, visit sharkaccessories.com.
sharkclean.comsharkclean.com
MAINTAINING YOUR VACUUM
MAINTAINING YOUR VACUUM
ACCESSING BRUSHROLLS CLEANING BRUSHROLLS
Open the brushroll garage by sliding back the release buttons. To close, insert the tabs on the lid into the slots on the nozzle, then press down both sides.
BRUSHROLL
Run scissors along the guide on the brushroll to remove any string, hair, or debris.
CHECKING FOR BLOCKAGES
Turn o vacuum and remove battery.
Remove the handheld vacuum from the wand and check all intake openings to the dust cup.
Turn o vacuum and remove battery.
Remove the hand vacuum and floor nozzle from the wand and check the wand for blockages.
To close the garage door lid, insert the tabs on the lid into the slots on the nozzle, then press down on both sides of the lid until it clicks securely into place.
NOTE: If the headlights are flashing, the brushroll garage lid is not clicked securely into place on both sides . The lights will flash and the brushrolls will not spin until both sid es of the lid are securely clicked into place.
SOFT ROLLER
Pull out roller by the tab. Remove any string, carpet fibers, or hair, and remove debris from the roller housing. water. Air-dry completely for at least 24 hours before reinserting
Reinsert roller by sliding it into the front of the floor nozzle until it clicks into place.
Wash the roller as needed, using only
.
Turn o vacuum and remove battery.
Remove the floor nozzle from the wand. Tilt neck of floor nozzle back to straighten the airway to remove blockages.
sharkclean.comsharkclean.com
Loading...
+ 14 hidden pages