SGS Thomson Microelectronics ST21S07ACWR, ST21S07ACW, ST21S07ACTR Datasheet

1/10February 2001
FULLY COMPLIANT WITH SCSI , SC SI-2
AND EMERGING SCSI-E STANDARDS
PROVIDES ACTIVE TERMINATION FOR
NINE SIGNAL LINES
LOW DROPOUT (0.5V) VREGS:2.85V
FACTORY TRIMMED TERMINATI ON 110
POWER DOWN MODE ISOLATES
TERMINATION RESISTORS FROM THE BUS
FULLY SUPPORTS ACTI VELY NEGATED
SCSI SIGNALS
COMPATIBLE TO THE DS2107, DS2107A
AND DS21S07
ONBOARD THERMAL SHUTDOWN
CIRCUITRY
AVAILABLE IN SO-16L AND TSSOP20
SCSI BUS HOT PLUG-COMPATIBLE
DESCRIPTION
The SCSI-2 and SCSI-3 standards recommend the use of active terminations at both ends of every cable segment in a SCSI system with a single-ended drivers and reveivers. The ST21S07A SCSI terminator, which is fully
compliant with these standands, enables the designer to gain the benefits of active termination: greater immunity to voltages drop on the TERMPWR (TERMination PoWeR) line, enhanced high level noise immunity, intrinsic TERMPWR decouplig, and very low quiescent current consumption. The ST21S07A integrates a regulator and nine precise switched 110 termination resistors into a monolithic IC. The ST21S07A can be electri cally isolatesd from the SCSI bus without physical removal from the SCSI device.
ORDERING CODES
(*) Avai l abl e on reque st
Type Temperature Range Package Comments
ST21S07ACW 0 to 70 °C SO-16L (Tube) 49parts per tube / 25tube per box
ST21S07ACWR 0 to 70 °C SO-16L (Tape & Reel) 1000 parts per reel
S21S07ACTR (*) 0 to 70 °C TSSOP20 (Tape & Reel) 2500 parts per reel
ST21S07A
SCSI TERMINATOR
SOP TSSOP
ST21S07A
2/10
PIN CONFIGURATION
PIN DESCRIPTION
PlN N°
(TSSP20)
PlN N°
(SO-16L)
SYMBOL NAME AND FUNCTION
1 1 TERMPWR1 Termina tion Power 1: Should be connected to the SCSI TERMPWR line.
Must be decoupled with either a 2.2µF or 4.7µF. See Fig. 2.
2 HS-GND Heat Sink Ground: Internally connected to the mounting pad. Should be
either grounded or electrically isolated from the other circuitry. 32R1Signal Termination 1: 110 Termination 43R2Signal Termination 2: 110 Termination 54R3Signal Termination 3: 110 Termination 65R4Signal Termination 4: 110 Termination 76R5Signal Termination 5: 110 Termination 8 HS-GND Heat Sink Ground: Internally connected to the mounting pad. Should be
either grounded or electrically isolated from the other circuitry. 97V
REF1
Reference Voltage 1: Must be external connected directly to the V
REF2
pin. Must be decoupoled with 4.7µF capacitor as shown in Figure 2
10 8 GND Ground: Signal groud: 0V 11 9 TERMPWR Termination Power21: Should be connected to the SCSI TERMPWR line.
Must be decoupled with either a 2.2µF or 4.7µF. See Fig. 2.
12 HS-GND Heat Sink Ground: Internally connected to the mounting pad. Should be
either grounded or electrically isolated from the other circuitry.
13 10 R6 Signal Termination 6: 110 Termination 14 11 R7 Signal Termination 7: 110 Termination 15 12 R8 Signal Termination 8: 110 Termination 16 13 R9 Signal Termination 9: 110 Termination 17 14 NC Not connected: Do not connect any signal to this pin 18 HS-GND Heat Sink Ground: Internally connected to the mounting pad. Should be
either grounded or electrically isolated from the other circuitry.
19 15 V
REF2
Reference Voltage 2: Must be external connected directly to the V
REF1
pin. Must be decoupoled with 4.7µF capacitor
20 16 PD
Power Down: When tied low, the ST21S07A enters a power down mode.
Contains an internal 60K pull-up. Strap low to deactivate the ST21S07A,
leave open circuited to activate the ST21S07A
SO-16L TSSOP20
ST21S07A
3/10
ABSOLUTE MAXIMUM RATINGS
Absolute Maximum Ratings are those values beyond which damage to the device may occur. Functional operation under these condition is not implied.
RECOMMENDED OPERATING CONDITIONS
DC CHARACTERISTICS (T
A
= 0 to 70°C, unless otherwise specified.)
REGULATOR CHARACTERISTICS (T
A
= 0 to 70°C, unless otherwise specified.)
Note 1: TERMPWR = 4V to 5.5V Note2: Si gnal Lines = 0V to T ER M PWR Note3: Al l signal lines = 0V Note 4: Al l s i gnal lines open Note 5: PD
= 0V Note 6: Gua ranteed by design; not production t ested Note 7: R
1
through R9 only
Note 8: R
1
through R9 and PD
Note 9: V
SIGNAL
= 0.2V
Symbol Parameter Value Unit
V
PIN
Voltage on Any Pin Relative to Ground
-1 to 7 V
T
stg
Storage Temperature Range
-55 to +150 °C
T
op
Operating Junction Temperature Range
0 to +70 °C
Symbol Parameter Test Conditions Min. Typ. Max. Unit
V
TP
TERMPWR Voltage 4 5.5 V
V
PDA
PD Active -0.3 0.8 V
V
PDI
PD Inactive 2 VTP+0.3 V
Symbol Parameter Test Conditions Min. Typ. Max. Unit
I
TP
TERMPWR Current (note 1, 3)
(note 1, 4) 1.5
250
8
mA mA
I
PD
Power Down Current (note 1, 2, 5) 70 150 µA
R
TERM
Termination Resistance (note 1, 2) 108 110 112
T
SD
Die Thermal Shutdown (note 1, 6) 150 170 °C
C
PD
Power Down Termniatio N Capacitance
(note 1, 2, 5, 6) 3 5 pF
H
PD
Power Down Hysteresis (note 1) 280 mV
I
IH
Input Leackage High (note 1, 8) -1 µA
I
IL
Input Leackage Low (note 1, 7) 1 µA
Symbol Parameter Test Conditions Min. Typ. Max. Unit
V
REF
Output Voltage (note 1, 2) 2.79 2.85 2.93 V
v
DROP
Drop-out Voltage (note 3, 6) 0.3 0.75 V
LI
REG
Line Regulation (note 1, 4) 0.25 2 %
LO
REG
Load Regulatio (note 1, 2) 0.5 3 %
I
LIM
Current Limit (note 1) 450 mA
I
SINK
Sink Current (note 1) 200 mA
I
OUT
Output Current (note9) 25.2 mA