ST21S07A
3/10
ABSOLUTE MAXIMUM RATINGS
Absolute Maximum Ratings are those values beyond which damage to the device may occur. Functional operation under these condition is
not implied.
RECOMMENDED OPERATING CONDITIONS
DC CHARACTERISTICS (T
A
= 0 to 70°C, unless otherwise specified.)
REGULATOR CHARACTERISTICS (T
A
= 0 to 70°C, unless otherwise specified.)
Note 1: TERMPWR = 4V to 5.5V
Note2: Si gnal Lines = 0V to T ER M PWR
Note3: Al l signal lines = 0V
Note 4: Al l s i gnal lines open
Note 5: PD
= 0V
Note 6: Gua ranteed by design; not production t ested
Note 7: R
1
through R9 only
Note 8: R
1
through R9 and PD
Note 9: V
SIGNAL
= 0.2V
Symbol Parameter Value Unit
V
PIN
Voltage on Any Pin Relative to Ground
-1 to 7 V
T
stg
Storage Temperature Range
-55 to +150 °C
T
op
Operating Junction Temperature Range
0 to +70 °C
Symbol Parameter Test Conditions Min. Typ. Max. Unit
V
TP
TERMPWR Voltage 4 5.5 V
V
PDA
PD Active -0.3 0.8 V
V
PDI
PD Inactive 2 VTP+0.3 V
Symbol Parameter Test Conditions Min. Typ. Max. Unit
I
TP
TERMPWR Current (note 1, 3)
(note 1, 4) 1.5
250
8
mA
mA
I
PD
Power Down Current (note 1, 2, 5) 70 150 µA
R
TERM
Termination Resistance (note 1, 2) 108 110 112 Ω
T
SD
Die Thermal Shutdown (note 1, 6) 150 170 °C
C
PD
Power Down Termniatio N
Capacitance
(note 1, 2, 5, 6) 3 5 pF
H
PD
Power Down Hysteresis (note 1) 280 mV
I
IH
Input Leackage High (note 1, 8) -1 µA
I
IL
Input Leackage Low (note 1, 7) 1 µA
Symbol Parameter Test Conditions Min. Typ. Max. Unit
V
REF
Output Voltage (note 1, 2) 2.79 2.85 2.93 V
v
DROP
Drop-out Voltage (note 3, 6) 0.3 0.75 V
LI
REG
Line Regulation (note 1, 4) 0.25 2 %
LO
REG
Load Regulatio (note 1, 2) 0.5 3 %
I
LIM
Current Limit (note 1) 450 mA
I
SINK
Sink Current (note 1) 200 mA
I
OUT
Output Current (note9) 25.2 mA