PETROL GENERATOR
PAGE 3
PAGE 2
WARRANTY
This generator is covered by a 24 month warranty from the initial date of purchase. This is a domestic warranty provided directly by SGS Engineering. Please keep a recipt of your pucr­chase as this may be required as proof of purchase.
You will invalidate your warranty if the product is found to have been misused, tampered with, modified, overloaded or used for a commercial application for which it was not de­signed. The warranty will also be rendered invalid if the main­tenance prodcedure has not been followed.
You must contact SGS Engineering prior to returning any product. This warranty does not effect your statutory rights.
TABLE OF CONTENTS
WARRANTY 2 TABLE OF CONTENTS 3 UNDERSTANDING THE GENERATOR GENERATOR SAFETY 4 EXHAUST GAS PRECAUTIONS 5 EARTHING THE GENERATOR 5 COMPONENTS LOCATION DIAGRAM 6 PREPARING YOUR GENERATOR FIXING THE WHEELS 8 FILLING THE GENERATOR WITH OIL 9 FILLING THE GENERATOR WITH PETROL 10 STARTING THE GENERATOR Pull start. 11 Electric start. 12 USING THE GENERATOR OPERATING THE GENERATOR 15 SHUTTING DOWN THE GENERATOR 16 TROUBLESHOOTING, MAINTENANCE & SERVICING TROUBLESHOOTING STARTING A GENERATOR 17 GENERATOR TROUBLESHOOTING Generator will not start. 18 Generator is difficult to start. 18 No electrical output. 19 Engine making “revving” sounds 19 MAINTENANCE SCHEDULE 20 MAINTENANCE INSTRUCTIONS Spark plug maintenance. 21 Air filter maintenance. 21 Engine oil maintenance. 22 Fuel filter maintenance. 22 Draining the fuel. 23 Draining the oil. 23 CERTIFICATE OF CONFORMITY 24
WWW.SGS-ENGINEERING.COM CALL FOR ASSISTANCE: 01332 576 850
PAGE 5
PAGE 4
EXHAUST GAS PRECAUTIONS
• Always ensure that there is adequate ventilation when using the generator.
• Always position the generator so that the exhaust is point­ing away from people or animals.
• Never use the generator indoors or in an enclosed area. (i.e workshop, garage, lockup etc)
EARTHING THE GENERATOR
• In most situations the frame of a portable generator need not be grounded (connected to earth) and the frame may serve as the earth.
• An earth connector lug is fitted to the generator, for use if required to connect to an earth. This connection should only be undertaken after full consultation with a competent, qualified electrician.
• Earth spike not provided as not required for general use.
Exhaust fumes can be fatal!
GENERATOR SAFETY
Only use outdoors.
Never use during wet conditions.
Do not smoke whilst handling fuels.
In emergency, switch engine switch to ‘off’.
Always operate on level ground!
If in doubt about anything, contact us on (+44) 01332 576 850.
Always consult this manual for effective product knowledge.
WWW.SGS-ENGINEERING.COM CALL FOR ASSISTANCE: 01332 576 850
PAGE 7
PAGE 6
GENERATOR COMPONENTS LOCATION DIAGRAM
230 V
output
12 V
charging
outputs
Handle (certain
models only)
Fuel tank
Air filter box
Engine switch
Wheels (certain models only)
Pull start
115 V
output
GENERATOR COMPONENTS LOCATION DIAGRAM
Choke selector
Spark
plug
Carburettor
adjustment
screw
Oil filler cap
Fuel gauge
WWW.SGS-ENGINEERING.COM CALL FOR ASSISTANCE: 01332 576 850
PAGE 9
PAGE 8
FIXING THE WHEELS (SPG3000, SPG6500)
1. Push the axle through the wheel.
2. Slot the wheel and axle on the frame.
3. Insert split pin through axle hole and spread pin.
DO NOT tip the generator on its side to fit the wheels.
FILLING THE GENERATOR WITH OIL
1. Remove the oil reservoir filter cap.
2. Fill with 10W30 oil to the centre line of the dipstick.
3. Wipe up any oil spillages with a rag.
4. Re-insert the oil reservoir filler cap.
Tip: When filling with oil, use a funnel with a hose. NEVER tip the generator onto its side to fill with oil.
ONLY USE 10w30 GRADE OIL. Other oils will pre­vent the generator from starting.
WWW.SGS-ENGINEERING.COM CALL FOR ASSISTANCE: 01332 576 850