SGS SC50H, SC24H Owner's Manual

FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.
OWNER’S MANUAL
SC24H & SC50H AIR COMPRESSOR
PAGE 3
PAGE 2
MAIN COMPONENTS
1. Main compressor
2. Pressure switch
3. Outlet Valve
4. Regulating Valve
5. Pressure gauge
6. One-way Valve
7. Drain cock
8. Wheels
9. Discharge pipe
10. Air tank resevoir
11. Safety valve
12. Fan cover
SPECIFICATION
LIST OF GOODS
ITEM LIST OF GOODS QTY
1 Air Compressor 1 2 Air Filter 1 3 Breather Pipe 1 4 Wheel 2 5 Wheel Axis 2 6 Rubber Gasket 1 or 2 7 Instruction Manual 1
ITEM DATA
Model SC24H SC50H
Power 1.5 kW / 2.5 HP
Voltage 230 V
Frequency 50 Hz
Motor Poles 2 P
Rated Speed 2850 rpm
Current 7.5 A
Delivery 9.6 CFM
Discharge Pressure 115 PSI / 0.8 MPa
Restart Pressure 70 PSI / 0.5 MPa
Tank Capacity 24 L 50 L
Dimensions
600x290x645 mm 770x330x730 mm
Air Outlet Size 1/4”
Net Weight 30 kg 38 kg
Noise Information LWA 97 dB
12.
WWW.SGS-ENGINEERING.COM
1. 2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
PAGE 5
PAGE 4
TRAINING: Prior to use, all users must become familiar with the instructions given in this manual. In particular, become familiar with the ON/OFF control for stopping the compressor in the event of an emergency.
ALWAYS USE EYE PROTECTION: When operating the air com­pressor, always use eye protection such as goggles, and make sure that other people in the work area are also using eye protection. Eye protectors must provide protection from flying particles both from the front and from the side.
PROTECT YOUR HEARING: Hearing protection should be worn when operating this compressor, use ear plugs or ear defenders.
NEVER TOUCH MOVING PARTS: Never place your hand near any moving parts on the air compressor or operate with the covers removed.
PROTECT YOUR SELF AGAINST ELECTRIC SHOCK: Never oper­ate the air compressor in wet or damp locations.
DRESS PROPERLY: Loose clothing or jewellery may be caught in moving parts. Always tie long hair back, and wear suitable clothing.
SAFETY PRECAUTIONSWARNING SYMBOLS
READ THIS INSTRUCTION MANUAL CARE­FULLY BEFORE OPERATING OR ADJUSTING THE COMPRESSOR.
Risk of electric shock. The compressor must be disconnected from the mains supply before maintenance or removing any covers. Do not use in a damp environment.
Risk of accidental start-up. The compressor could start automatically in the event of a power cut and subsequent reset. Do not carry the compressor while it is connected to the power source, or when the tank is filled with compressed air.
This compressor contains surfaces which may reach a high temperature during operation. Never operate with the motor housing re­moved.
Air and condensation water can burst from the compressor when the drain plug is removed.
Wear a safety goggles and ear protectors when using this compressor.
This compressor produces a high sound level during operation. Ear protection should be worn.
WWW.SGS-ENGINEERING.COM
PAGE 7
PAGE 6
DISCONNECT THE AIR COMPRESSOR: Always disconnect the air com-
pressor from the mains power supply and decompress before performing
maintenance, changing any parts and when not in use.
MAINS POWER CABLE PRECAUTIONS: Never pull on the cable when
removing the plug from the mains socket, or lift the compressor by the
mains cable.
AVOID UNINTENTIONAL STARTING: When connecting the air compres-
sor to the mains supply make sure the red button on top of the air com-
pressor is in the OFF (down) position.
STORE THE AIR COMPRESSOR PROPERLY: When not in use the air com-
pressor should be stored in a secure, dry place out of the reach of children.
Always lock up the storage area.
MAINTAIN THE AIR COMPRESSOR WITH CARE: If the air compressor is
damaged in any way, have it repaired by a qualified engineer.
DO NOT USE EXTENSION LEADS: Using extension leads can cause your
compressor motor to burn out. Only use extension hoses.
DO NOT WELD TO THE PRESSURE VESSEL
Do not weld or modify the pressure vessel in any manner.
SAFETY PRECAUTIONS
KEEP VISITORS/CHILDREN AWAY: Do not allow visitors/children to han-
dle the air compressor or attachments and ensure that any people in the
work area are suitably dressed.
KEEP THE WORK AREA CLEAN: Cluttered areas mean accidents, so clear
the work area of all unnecessary tools, debris and furniture.
DO NOT TOUCH HOT SURFACES: During operation, the motor, con-
nections, compressor body, cylinder head and tubes may get hot, do not
touch.
DO NOT DIRECT AN AIR STREAM AT THE BODY: Do not direct the air
stream at people or animals, as injury may result. Compressed air can cause
soft tissue damage and propel dirt and other particles at high speed.
BREATHING AIR: This compressor should not be used to supply breathing
quality air. Never use it as breathing apparatus.
STAY ALERT: Watch what you are doing, use common sense, and do not
operate the air compressor when you are tired. The air compressor should
not be used if you are under the influence of alcohol, drugs or any medica-
tion that makes you drowsy.
DISPOSAL INFORMATION
The air compressor should be disposed of in a safe an environmentally
friendly manner. Contact your local Council for disposal assistance.
SAFETY PRECAUTIONS