SFA Sanicom FF03-P95 User Manual

1. Description
Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance level, and is safe and reliable, provided all the rules for installation and maintenance in this notice are strictly followed. Especially those indicated by:
Failure to comply with this instruction could endanger the safety of persons
Indication that a risk of electrical origin exists
Electrical installation must be carried out by a professional electrician.
2. List of Accessories included
25 x 40
A B C D
E F G H
I
x2
x1 x2 x2
x1
x1 x2 x2
x1
Hose clip
Hose clip
Inlet Cover
Hose clip Screw
Plug
Elbow
Hose clip
Flexible inlet connector
For any additional information, please contact our customer service department.
32 x 50 50 x 70
40 x 60
Please also see “10 golden rules” for correct Saniflo installation on www.saniflo.co.uk
3. Dimensions and overall measurements
4. How it works
The Sanicom contains 1 pump. The tank is equipped with a sensor tube which controls the automatic activation of the motor when waste enters the unit. As soon as the waste enters the tank, the pump starts.
5. Performance Curve & Height and Length of the discharge pipe
Flow Rate - litre/min
Vertical Height - Metres
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
12 11 10
9 8 7 6 5 4 3 2 1 0
max 10m
3
7
4m
3m
2m
1m
5m
6m
7m
1%
Max 8m
max 20m
max 30m
max 40m
max 50m
max 60m
max 70m
max 80m
420mm
330mm
490mm
ø 60
230mm
6. Technical Data & Application
7. Installation
FITTING
The Sanicom can be fixed to the floor, preventing it from turning or moving.
1. Warning: The space in which the Sanicom is installed must be large enough to leave at least 600mm around the unit for easy maintenance. This space must be well lit, ventilated, and must never be immersed in water and must be protected from frost.
2. Isolation valves should be fitted to the inlet pipework and discharge pipework to isolate the unit in case of the need for service.
Application Commercial sink, washing machine,
dishwasher or shower* or bath*
Type FF03-P95
Maximum vertical pumping height 8m
Voltage 220 – 240 V
Frequency 50 Hz
Maximum power consumption 750 W
Maximum current consumption 3.3 A
Electrical class I
Protection index IP44
Max temp with intermittent functioning 80°
Net weight 10 kg
* In the case of bath or shower tray, make sure the waste traps are raised 15cm above floor level.
CAUTION: 1. All applications other than those described in this notice are prohibited.
2. Do not exceed an incoming flow rate greater than 80% of the flow rate stated on the design curve in any of the apparatus.
8. Connection to side inlets
Use the flexible inlet connector (A) for side inlet connections. Using a metalwork saw, saw off the desired inlet point, remove any burrs and then fix the flexible inlet connector with the hose clip (D).
We recommend the installation of a grease trap for installations with a high grease inflow.
Connection to the inlet can be made using a 40mm or 50mm pipe. To make a 50mm connection, cut off the end of sleeve (A) beforehand.