SEW MOVITRAC LTE-B Operating Instructions Manual

Drive Technology \ Drive Automation \ System Integration \ Services
Operating Instructions
MOVITRAC
®
LTE-B
Edition 09/2010 16923626 / EN
SEW-EURODRIVE—Driving the world
Operating Instructions – MOVITRAC® LTE-B
3
1 Important Notes................................................................................................. 4
1.1 Structure of the safety notes ..................................................................... 4
1.2 Application environment............................................................................ 6
1.3 Waste disposal.......................................................................................... 6
2 Safety Notes ............................................. ... ... .... ... ... ......................................... 7
2.1 Installation and startup.................................................. ............................ 7
2.2 Operation and servicing................... ... ... .... ... ... ......................................... 8
3 General specifications...................................................................................... 9
3.1 Input voltage ranges ..................................... ... ... ... ................................... 9
3.2 Product designation .................................................................................. 9
3.3 Overload capability ................................................................................. 10
3.4 Protection features.................................................................................. 10
4 Mechanical Installation................................................................................... 11
4.1 Dimensions ............................................................................................. 11
4.2 IP20 housing: mounting and dimensions of switch cabinet..................... 16
5 Electrical Installation ............................................................ ... ....................... 18
5.1 Prior to installation .................................................................................. 18
5.2 Installation...............................................................................................20
5.3 Signal terminals overview ....................................................................... 24
5.4 RJ45 Communication Socket.................................................................. 25
5.5 UL-compliant installation......................................................................... 26
5.6 Electromagnetic compatibility................................. .... ... ... ... .... ... ... ... ....... 27
6 Startup.............................................................................................................. 29
6.1 User interface.......................................................................................... 29
6.2 Easy startup..................................................................... ... .... ... ............. 30
7 Operation ......................................................................................................... 35
7.1 Drive status............................................................................................. 35
8 Service and fault codes .................................................................................. 36
8.1 Troubleshooting ...................................................................................... 36
8.2 Fault history ........................................... .... ......................................... .... 36
8.3 Fault codes ................................................ ... ... ....................................... 37
8.4 SEW electronics service .................................................................. ... .... 38
9 Parameters....................................................................................................... 39
9.1 Standard parameters .............................................................................. 39
9.2 Extended parameters.............................................................................. 40
9.3 P-15 Digital inputs function select...........................................................44
9.4 Real-time monitoring parameters (read-only) ......................................... 46
10 Technical Data................................................................................................. 48
10.1 Conformance .......................................................................................... 48
10.2 Environmental .........................................................................................48
10.3 Output power and current ratings............................................................49
11 Index................................................................................................................. 58
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
4
Operating Instructions – MOVITRAC® LTE-B
1
Structure of the safety notes
Important Notes
Operating Instructions
1 Important Notes
1.1 Structure of the safety notes
1.1.1 Meaning of the signal words
The following table shows the grading and meaning of the signal words for safety notes, notes on potential risks of damage to property, an d ot he r no te s.
1.1.2 Structure of the section safety notes
The section safety notes do not apply to a specific action, but to several actions pertain­ing to one subject. The pictograms used indicate either a general or a specific hazard.
This is the formal structure of a section safety note:
This is an example for a section safety note:
Signal Word Meaning Consequences if disregarded
DANGER Imminent danger Severe or fatal
injuries
WARNING Possible dangerous situation Severe or fatal
injuries
CAUTION Possible dangerous situation Minor injuries
NOTICE Possible damage to property Damage to the drive system or its environ-
ment
INFORMATION Useful information or tip: Simplifies
the handling of the drive system.
SIGNAL WORD
Nature and source of hazard. Possible consequence(s) if disregarded.
Measure(s) to prevent the hazard.
WARNING
Falling of suspended loads. Severe or fatal injuries.
Do not stand under the suspended load.
Secure the danger zone.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Operating Instructions – MOVITRAC® LTE-B
5
1
Structure of the safety notes
Important Notes
1.1.3 Structure of the embedded safety notes
The embedded safety notes are directly integrated in the instructions just before the description of the dangerous action.
This is the formal structure of an embedded safety note:
SIGNAL WORD Nature and source of hazard. Possible consequence(s) if disregarded. – Measure(s) to prevent the hazard.
This is an example for an embedded safety note:
DANGER Risk of crushing if the drive restarts unintentionally. Severe or fatal injuries. – De-energize the drive.
– Secure the drive against unintended restart.
Unless the information in the operating instructions is adhered to, it will be impossible to ensure:
Trouble-free operation
Fulfillment of any rights to claim under guarantee
Consequently, read the operating instructions before you start working with the unit!
The operating instructions contain important information about servicing. Therefore, keep the operating instructions close to the unit.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
6
Operating Instructions – MOVITRAC® LTE-B
1
Application environment
Important Notes
1.2 Application environment
The following applications are forbidden unless measures are expressly taken to make them possible:
Use in explosion-proof areas.
Use in environments with harmful substances: – Oils
–Acids – Gases – Vapors –Dust – Radiated interference – Other harmful environments
Use subject to mechanical vibration and shock loads in excess of the requirements in EN 50178.
If the inverter performs safety functions which have to guarantee the protection of machinery and people.
1.3 Waste disposal
Please follow the current instructions: dispose in accordance with the regulations in force:
Electronics scrap (printed-circuit boards)
Plastic (housing)
Sheet metal
Copper
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Operating Instructions – MOVITRAC® LTE-B
7
2
Installation and startup
Safety Notes
2 Safety Notes
MOVITRAC® LTE-B drive inverters may not perform safety functions without higher­level safety systems.
Do not use MOVITRAC
®
LTE-B drive inverters for any safety functions in conjunction
with hoist applications.
2.1 Installation and startup
Never install or start up damaged products. Please submit a complaint to the transport company immediately in the event of damage.
Installation, startup and service work on the unit only by trained personnel. The personnel must be trained in the relevant aspects of accident prevention and must comply with the regulations in force (e.g. EN 60204, VBG 4, DIN-VDE 0100/0113/0160).
Follow the specific instructions during installation and startup of the motor and the brake!
Make sure that preventive measures and protection devices correspond to the applicable regulations (e.g. EN 60204 or EN 50178).
Grounding the unit is a necessary protective measure. Overcurrent protection devices are a necessary protective measure.
The unit meets all requirements for reliable isolation of power and electronics connections in accordance with UL508. All connected circuits must also satisfy the requirements for reliable isolation in order to guarantee reliable isolation.
Take suitable measures to ensure that the connected motor does not start up automatically when the inverter is switched on. To do this, you can connect binary inputs DI01 through DI03 to GND.
Integral solid state short circuit protection d oes not provide branch circuit pro- tection. Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
8
Operating Instructions – MOVITRAC® LTE-B
2
Operation and servicing
Safety Notes
2.2 Operation and servicing
Dangerous voltages are present in the output terminals and the cables and motor terminals connected to them when the unit is switched on. Dangerous vo ltage s may also be present when the unit is inhibited and the motor at a standstill.
The unit is not necessarily deenergized when the LEDs and the 7-segment display are off.
Safety functions inside the unit or a mechanical blockage may cause th e motor
to stop. The removal of the source of the malfunction or a reset can result in an automatic restart of the drive. If, for safety reasons, this is not permissible for the
driven machine, disconnect the unit from the supply system before correcting the fault.
WARNING
Danger of electrical shock. High voltages are present in the terminals and within the drive for up to 10 minutes after the electrical supply has be en disc on ne ct ed .
Severe or fatal injuries.
Disconnect and isolate the MOVITRAC
®
LTE-B from the electrical supply at least
10 minutes before commencing any work on it.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Operating Instructions – MOVITRAC® LTE-B
9
3
Input voltage ranges
General specifications
3 General specifications
3.1 Input voltage ranges
Depending on model and power rating the drives are designed for direct connection to the following supplies:
MOVITRAC
®
LTE-B sizes 1, 2 (115 V input):
115 V ± 10 %, 1-phase, 50 – 60 Hz ± 5 %
MOVITRAC
®
LTE-B sizes 1, 2 and 3s (200 – 240 V):
200 V – 240 V ± 10 %, 1-phase* / 3-phase, 50 – 60 Hz ± 5 %
MOVITRAC
®
LTE-B sizes 1, 2 and 3s (380 – 480 V):
380 V – 480 V ± 10 %, 3-phase, 50 – 60 Hz ± 5 %
INFORMATION *It is also possible to connect 1-phase MOVITRAC
®
LTE-B units to 2-phases of a
200 – 240 V, 3-phase ma in s.
Products used with a 3-phase supply are designed for a maximum supply imbalance of 3 % between phases. For input supplies which have a supply imbalance greater than 3 % (typically the Indian subcontinent and parts of the Asia Pacific including China) SEW-EURODRIVE recommends that input chokes are used.
3.2 Product designation
MC LTE B 0015 2 0 1 1 00 (60 Hz)
60Hz American version only
Type
00 = Standard IP20 housing 10 = IP55 / NEMA 12 housing 20 = IP55 / NEMA 12 housing with switch 40 = IP66 / NEMA 4X housing with switch
Quadrants
1 = 1Q (without brake chopper) 4 = 4Q
Connection type
1 = 1-phase 3 = 3-phase
Interference suppression on the supply side
0 = class 0 A = class A B = class B
Mains voltage
1 = 115 V 2 = 200 – 240 V 5 = 380 – 480 V
Recommended motor power
0015 = 1.5 kW
Version B
Product type MC LTE
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
10
Operating Instructions – MOVITRAC® LTE-B
3
Overload capability
General specifications
3.3 Overload capability
All MOVITRAC® LTE-B units have a possible overload of:
150 % for 60 seconds
175 % for 2 seconds
The overload is reduced to 150 % for 7.5 seconds if the output frequency is below 10 Hz.
For motor overload adjustment see parameter P-08 in chapter "Standard parameters" (page 39).
3.4 Protection features
Output short-circuit, phase-to-phase, phase-to-ground
Output over-current
Overload protection
– Drive delivers 150 % of rated motor current for 60 seconds.
Over-voltage trip
– Set at 123 % of drive maximum rated supply voltage.
Under-voltage trip
Over temperature trip
Under temperature trip
– Drive will trip if enabled below –10 °C
Supply phase loss
– A running drive will trip if one phase of a 3-phase supply is lost for more than
15 seconds.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Operating Instructions – MOVITRAC® LTE-B
11
4
Dimensions
Mechanical Installation
4 Mechanical Installation
Inspect the MOVITRAC® LTE-B carefully prior to installation to ensure it is undam­aged.
Store the MOVITRAC
®
LTE-B in its box until required. Storage should be clean and
dry and within the ambient temperature range –40 °C to 60 °C.
Install the MOVITRAC
®
LTE-B on a flat, vertical, flame-resistant, vibration-free surface, within a suitable switch cabinet. This should be according to EN 60529 if specific Ingress Protection (IP) ratings are required.
Do not place flammable material close to the drive.
Prevent the entry of conductive or flammable foreign bodies.
The maximum ambient operating temperature is 50 °C for IP20 and 40 °C for IP55 / IP66 drives. The minimum ambient operating temperature is –10 °C.
Please observe the specific ratings employed in chapter "Environmental" (page 48).
Relative humidity must be less than 95 % (non-condensing).
•MOVITRAC
®
LTE-B units can be installed side-by-side. This gives adequate venti-
lation space between them. If the MOVITRAC
®
LTE-B is to be installed above anoth­er drive or any other heat-producing device, the minimum vertical spacin g is 150 mm. The switch cabinet should either be force-ventilated or large enough to allow natural cooling (see chapter "IP20 housing: mo un ting and dimensions of switch cabinet" on page 16).
A DIN rail mounting is supported in size 1 and 2 (IP20) drives only.
4.1 Dimensions
MOVITRAC® LTE-B is available in 3 housing versions:
Standard IP20 housing for use in switch cabinets
•IP55/NEMA 12K
•IP66/NEMA 4X The IP55 / NEMA 12 K and IP66 / NEMA 4X housing is protected against moisture and
dust. Therefore, the drives can be operated indoors under harsh conditions. Electroni­cally, the drives are identical and the only differences ar e the dimensions of the housing and the weight.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
12
Operating Instructions – MOVITRAC® LTE-B
4
Dimensions
Mechanical Installation
4.1.1 Dimensions of the IP20 housing
62741AXX 62742AXX 62743AXX
Dimension Size 1 Size 2 Size 3
A (Height) [mm] 174 220 261
[in] 6.85 8.66 10.28
B (Width) [mm] 79 104 126
[in] 3.11 4.10 4.96
C (Depth) [mm] 122.6 150 178
[in] 4.83 5.90 7.01
Weight [kg] 1.1 2.0 4.5
[lb] 2.43 4.40 10.0
a [mm] 50.0 63.0 80.0
[in] 1.97 2.48 3.15
b [mm] 162 209.0 247
[in] 6.38 8.23 9.72
c [mm] 16 23 25.5
[in] 0.63 0.91 1.02
d [mm] 5.0 5.25 7.25
[in] 0.2 0.21 0.29
Power terminal torque settings
[Nm] 1.0 1.0 1.0
[lb.in] 8.85 8.85 8.85
Recommended screw size 4 × M4 4 × M4 4 × M4
A
B
UVW
1357911246810
L1/L L2/N L3
C
acc
d
b
d
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Operating Instructions – MOVITRAC® LTE-B
13
4
Dimensions
Mechanical Installation
4.1.2 Dimensions of the IP55 / NEMA 12 housing (LTE xxx –10 and –20)
60198AXX 60200AXX 64482AXX 60497AXX
Dimension Size 1 Size 2 Size 3
Height (A) [mm] 200 310 310
[in] 7.9 12.2 12.2
Width (B) [mm] 140 165 211
[in] 5.5 6.5 8.31
Depth (C) [mm] 165 176 240
[in] 6.5 6.9 9.45
Weight [kg] 2.3 4.5 7.4
[lb] 5.1 9.9 12.4
a [mm] 128 153 196
[in] 5 6 7.72
b [mm] 6 6 7
[in] 0.23 0.23 0.28
c [mm] 25 25 25
[in] 0.98 0.98 0.98
d [mm] 142 252 251
[in] 5.6 9.9 9.88
Power terminal torque settings
[Nm] 1 1 1
[lb.in] 8.85 8.85 8.85
Control terminal torque settings
[Nm] 0.5 0.5 0.5
[lb.in] 4.43 4.43 4.43
Recommended screw size 2 × M4 4 × M4 4 × M4
A
B
C
d
b
c
a
b
XX
Y
Z
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
14
Operating Instructions – MOVITRAC® LTE-B
4
Dimensions
Mechanical Installation
4.1.3 Dimensions of the IP66 / NEMA 4X housing (LTE xxx –40)
68096AXX 68095AXX 64482AXX 60497AXX
Dimension Size 1 Size 2 Size 3
Height (A) [mm] 232 257 310
[in] 9.13 10.12 12.20
Width (B) [mm] 161 188 210.5
[in] 6.34 7.4 8.29
Depth (C) [mm] 179 186.5 228.7
[in] 7.05 7.34 9
Weight [kg] 2.8 4.6 7.4
[lb] 6.2 10.1 16.3
a [mm] 148.5 176 197.5
[in] 5.85 6.93 7.78
b [mm] 6.25 6 6.5
[in] 0.25 0.24 0.26
c [mm] 25 28.5 33.4
[in] 0.98 1.12 1.31
d [mm] 189 200 251.5
[in] 7.44 7.87 9.9
Power terminal torque settings
[Nm] 1 1 1
[lb.in] 8.85 8.85 8.85
Control terminal torque settings
[Nm] 0.5 0.5 0.5
[lb.in] 4.43 4.43 4.43
Recommended screw size 4 × M4 4 × M4 4 × M4
A
B
C
d
b
c
a
b
XX
Y
Z
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Operating Instructions – MOVITRAC® LTE-B
15
4
Dimensions
Mechanical Installation
Cable glands A suitable cable gland system must be used to maintain the appropriate IP / NEMA
rating. Cable entry holes must be drilled for this system. The recommended sizes are detailed in the table below.
Lock off for IP55 / IP66 with switching option
On the switched drive the main power isolator switch can be locked in the "off" position using a 20 mm standard shackle padlock (not supplied).
Depress the centre of the switch to open the hole to insert the padlock.
Dimension Size 1 Size 2 Size 3
X [mm] 22.3 28.2 28.2
[in] 0.88 1.11 1.11
PG PG13.5/M20 PG16/M22 PG16/M22
Y
1)
1) Glands Y and Z are flip out glands.
[mm] 22 22 22
[in] 0.87 0.87 0.87
PG PG13.5 / M20 PG13.5 / M20 PG13.5 / M20
Z
1)
[mm] 17 17
[in] 0.67 0.67
PG PG9 / M16 PG9 / M16
65207AXX
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
16
Operating Instructions – MOVITRAC® LTE-B
4
IP20 housing: mounting and dimensions of switch cabinet
Mechanical Installation
4.2 IP20 housing: mounting and dimensions of switch cabinet
For applications that require a higher IP rating than the IP20 offered by the standard housing, the drive must be mounted in a switch cabinet. The following guidelines should be observed for these applications:
The switch cabinet should be made from a thermally conductive material, unless forced ventilation is used.
When a vented switch cabinet is used, there sho uld be ventin g above and below the drive to ensure good air circulation. Air should be drawn in below the drive and expelled above the drive.
If the external environment contains contam ination particles (e.g. dust), a suitable particle filter should be fitted to the vents and forced ventilation implemented. The filter must be serviced and cleaned as and when necessary.
Environments with a high moisture, salt or chemical content should use a suitably sealed (non-vented) switch cabinet.
4.2.1 Dimensions of non-vented metal switch cabinet
Drive power rating
Sealed switch cabinet
A B C D
[mm] [in] [mm] [in] [mm] [in] [mm] [in]
Size 1 0.37 kW, 0.75 kW 115 V
0.37 kW, 0.75 kW 230 V
300 11.81 250 9.84 200 7.87 50 1.97
Size 1 1.5 kW 230 V
0.75 kW, 1.5 kW 400 V
400 15.75 300 11.81 250 9.84 75 2.95
Size 2 1.1 kW 115 V
1.5 kW 230 V
1.5 kW, 2.2 kW 400 V
400 15.75 300 11.81 300 11.81 60 2.36
Size 2 2.2 kW 230 V
4.0 kW 400 V
600 23.62 450 17.72 300 11.81 100 3.94
62736AXX
Figure 1: Switch cabinet
A
D
D
C
B
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Operating Instructions – MOVITRAC® LTE-B
17
4
IP20 housing: mounting and dimensions of switch cabinet
Mechanical Installation
4.2.2 Dimensions of vented switch cabinet
4.2.3 Dimensions of force vented switch cabinet
Drive power rating
Vented switch cabinet
A B C D
[mm] [in] [mm] [in] [mm] [in] [mm] [in]
Size 1 All ratings 400 15.75 300 11.81 150 5.91 75 2.95 Size 2 All ratings 600 23.62 400 15.75 250 9.84 100 3.94 Size 3 All ratings 800 31.5 600 23.62 300 11.81 150 5.91
Drive power rating
Force vented switch cabinet (with fan)
A B C D
Air Flow[mm] [in] [mm] [in] [mm] [in] [mm] [in]
Size 1 All ratings 300 11.81 200 7.87 150 5.91 75 2.95 > 15 m
3
/h
Size 2 All ratings 400 15.75 300 11.81 250 9.84 100 3.94 > 45 m
3
/h
Size 3 All ratings 600 23.62 400 15.75 250 9.84 150 5.91 > 80 m
3
/h
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
18
Operating Instructions – MOVITRAC® LTE-B
5
Prior to installation
Electrical Installation
5 Electrical Installation
It is essential to comply with the safety instructions in chapter 2 during installa­tion.
•MOVITRAC
®
LTE-B units should only be installed by qualified electricians and in
accordance with local and national regulations and codes of practice.
The MOVITRAC
®
LTE-B has an Ingress Protection rating of IP20. For higher IP
ratings, use a suitable enclosure or the IP55 /NEMA 12 or IP66 / NEMA 4X version.
Where the electrical supply to the drive is through a plug and socket connector, do not disconnect until 10 minutes have elapsed after turning off the supply.
Ensure correct earthing connections. See diagram in chapter "Drive and motor connection" (page 22).
The earth cable must be sufficient to carry the maximum supply fault current which normally will be limited by the fuses or motor circuit breaker.
5.1 Prior to installation
Ensure that the supply voltage, frequency and nu mber of phases (single or 3- phase) correspond to the rating of the MOVITRAC
®
LTE-B as delivered.
An isolator or similar should be installed between the power supply and the drive.
Never connect the mains power supply to the MOVITRAC
®
LTE-B output terminals
U, V orW.
The cables are only protected when slow blow HRC fuses or a motor circuit breaker (MCB) are used. See chapter "Permitted voltage supply systems" (page 20) for further information.
Do not install any type of automatic switchgear between the drive and the motor. Wherever control cabling is close to power cabling, maintain a minimum separation of 100 mm and arrange crossings at 90 °.
Ensure that screening or armoring of power cables is effected in accordan ce with the connections diagram in chapter "Drive and motor connection" (page 22).
Ensure that all terminals are tightened to the appropriate torque.
WARNING
Danger of electrical shock. High voltages are present in the terminals and within the drive for up to 10 minutes after the electrical supply has be en disc on ne ct ed .
Severe or fatal injuries.
Disconnect and isolate the MOVITRAC
®
LTE-B from the electrical supply at least
10 minutes before commencing any work on it.
WARNING
Risk of fatal injury if the hoist falls. Severe or fatal injuries.
•MOVITRAC
®
LTE-B is not designed for use as a safety device in hoist applications.
Use monitoring systems or mechanical protection devices to ensure safety.