Setra Power Patrol User Manual

Page 1
POWER PATROL
what’s inside?
•Understanding your Energy Management Needs
•Why Rogowski Coils?
•Power Patrol vs. the Competition
•About the Power Patrol
SAVE MONEY - SAVE TIME - SIMPLIFY YOUR JOB
Page 2
UNDERSTANDING YOUR APPLICATION REQUIREMENTS
The rst rule in implementing any energy management program is to dene the objectives based on the application. Whether tasked reducing the energy consumption of a hospital, properly allocating costs across a university campus or enrolling an industrial plant in a utility demand re­sponse (DR) program, the goal of the program must dene the objectives. Products like the Power Patrol give access to detailed consumption data which pro­vides a facility manager or owner the tools necessary to view baselines, set goal targets and verify the results. Designed with the versatility to meet the demands of the most stringent applications, the Power Patrol com­bines industry leading performance with unmatched congurability and ease of installation.
PERFORMANCE & VERSATILITY FOR ANY APPLICATION
Revenue Grade Metering
Accuracy is paramount in revenue grade applications - and the Power Patrol delivers. The Power Patrol meets the ANSI 12.2 standard and is a revenue grade meter. The Power Patrol can transmit data seamlessly through a Building Automation System (BAS) or Building Energy Management System (BEMS) to manage your revenue grade needs:
• Tenant Billing
• Demand Response
• Net-Metering (Renewable Energy)
• Utility Energy Billing
Energy Management Metering
Selecting a meter for non-revenue grade applications; the customer requires a nice balance of reliability, performance, versatility and ease of installation at an attractive price point. Luckily - the Power Patrol satises this requirement too. Simply attach the Power Patrol to your PC via USB cable and using Setra’s HeadStart software select type of CT’s (Patrol Flex or Split Core), communication protocol (BACnet/Modbus through Ethernet/Serial), supply voltage and you are done in minutes! To eliminate complicated part numbering schemes, our industry rst USB conguration enables the user to utilize 1 model rather than building up to 50+ part numbers with competitive products.
• Green Building (LEED / Energy Star)
• Measurement & Verication
• Equipment Eciency Tracking
• Cost Allocation
Setra Systems, Inc.
Phone: 978.263.1400 || Fax: 978.264. 0292 || www.setra.com
SAVE MONEY - SAVE TIME - SIMPLIFY YOUR JOB
Page 3
Why would you use a Split-Core CT ever again?
Patrol Flex Rogowski Coil CT
Range: 5-5000+
Weight: <.27 lbs.
Accuracy: ±1% (including meter)
VS.
Standard Split-Core CT
Range: 0-3400
Weight: 8.4 lbs.
Accuracy: ±1% (CT only)
Range: 0-400
Weight: 3.6 lbs.
Accuracy: ±1% (CT only)
The Patrol Flex is the most accurate and highest per­formance Rogowski Coil in submetering. Offered in 12”, 24” and 36” lengths, the Rogowski Coils offer signicant installation advantages over split-core CT’s because of its light weight, wide current range (5-5000+ Amps), mechanical exibility for mounting in tight quarters and its easy placement around cable bundles or large bus bars.
• Size is not dependent on current range
• 12”, 24” and 36” all 5-5000 A
• Position sensitivity <.2% error
• Up to 5x better than competition
• Limited External Voltage inuence
• Up to 15x better than competition
The decision is easy, you wouldn’t.
Split-Core CT’s are not designed to
adapt to the unforgivable dimen-
sions of a Busbar.
Don’t be unprepared next time the
cable bundle is too thick for the
aperture in your CT.
Setra Systems, Inc.
Phone: 978.263.1400 || Fax: 978.264. 0292 || www.setra.com
SAVE MONEY - SAVE TIME - SIMPLIFY YOUR JOB
Page 4
Why Choose the Setra Power Patrol over the competition?
With a variety of submeters available on the market, it can be difcult to know which meter is right for your application. Check out the Power Patrol versus two of the leading meter manufacturers and see how it stacks up. If you value maximum versatility with­out sacricing performance, then the Power Patrol is the right solution for you.
Competitor
Setra Power Patrol
A
Leading
DINrail
Meter
Rogowski Coil
Compatible
Field Selectable
Rogowski Coil/
Hardware
Standard CT
Broadband Power
Supply
Ethernet
Competitor
B
Leading
Panel Meter
The Setra Patrol Flex is the highest per­formance Rogowski Coil in the industry;
oering better than 1% accuracy when connected to the Power Patrol
Flexibility to switch between Rogowski Coil and CT on the job; never get caught with the wrong hardware
Every Power Patrol model has the ability to be powered o of 80-600 VAC; no need to manage dierent models
Ethernet connectivity allows the Power Pa­trol to communicate quickly over BACnet
IP or Modbus TCP
The Power Patrol comes loaded with BAC-
Communication
Meter
Meter
Protocols
Cong.
Accuracy
4-in-1
USB
ANSI 12.2
Phone: 978.263.1400 || Fax: 978.264. 0292 || www.setra.com
net IP/Modbus TCP (ethernet) and BACnet MSTP/Modbus RTU (RS-485) oering the greatest eld exibility available today
Avoid being forced to congure the meter in a live enclosure - the Power Patrol is
powered and congured through a sim­ple USB to PC connection
Meets ANSI 12.2 Standards for Revenue Grade Requirements
Setra Systems, Inc.
SAVE MONEY - SAVE TIME - SIMPLIFY YOUR JOB
Page 5
The Setra Power Patrol is every electrical contractor’s dream. The networked 3-phase power meter works with Rogowski Coils and has a small enough form factor to be mounted inside or outside of the panel using either mount­ing tabs or the DINrail clip making it the easiest installation in the industry.
Power Patrol Features:
Rogowski and CT Compatible
The Power Patrol works with either Rogowski Coil “ex” CTs or conventional split-core CTs. The ability to have in­terchangeable CTs gives added exibility for last minute changes at the job site. The Power Patrol is embedded with the necessary amplier/integrator circuitry for Rogowski coil CTs—eliminating the need to provide external power.
Easy USB Conguration
Using the Power Patrol HeadStart software, power and con­gure the meter through your computer’s USB port. While other meter’s require conguration in a live enclosure, the Power Patrol can be easily congured outside of the pan­el, eliminating the risk of arc ash. HeadStart can save me­ter settings, allowing the installer to clone meter proles quickly and easily.
Line Powered from 80-600V
The Power Patrol series instruments are line-powered and do not require external power. Its power supply can accom­modate service voltages ranging from 80-600V (phase-to­phase). The Power Patrol has 3 LED indicators (Red/Green)
which conrm proper CT-to-phase installation.
Field Selectable Communications (4-in-1)
Each Power Patrol comes with a eld selectable Modbus or BACnet communication. Communications interface to the Power Patrol is through either an RS-485 serial connection (BACnet MS/TP / Modbus) or over Ethernet (BACnet IP / Modbus TCP).
• Congure & Power Through USB
Rogowski Coil and Split Core CT Compatible
Field Selectable BACnet/Modbus (4-in-1)
• Broadband Power Supply (80-600V)
• Optional Display for Setup and Monitoring
• ANSI C12.20-2010 Class 0.2
• Bi-Directional
• DIN- Mount
Applications:
• Measurement & Verication
• Demand Response
• Energy Cost Allocation
• Equipment Eciency Tracking
• Preventive Maintenance
• Tenant Sub-Metering
• Net Metering
5 Year Warranty
Setra Systems, Inc.
Phone: 978.263.1400 || Fax: 978.264. 0292 || www.setra.com
SAVE MONEY - SAVE TIME - SIMPLIFY YOUR JOB
Page 6
Modbus Register/BACnet Object Descriptions
(Partial List: Over 100 parameters available. Go to www.setra.com for full list and objects sheets.) System True Energy (kWh) Individual Phase to Phase Voltages Instantaneous Total True Power (kW) Line Frequency (Hz) Peak Demand (Adjustable Window) (kW) Individual Phases True Energy (kWh) Maximum Instantaneous Power (kW) Individual Phases True Power (kW) System Reactive Energy (kVARh) Individual Phases Reactive Energy (kVARh) System Apparent Energy (kVAh) Individual Phases Reactive Power (kVAR) System Apparent Power (kVA) Individual Phases Apparent Energy (kVAh) System Displacement Power Factor (dPF) Individual Phases Apparent Power (kVA) System Apparent Power Factor (aPF) Individual Phases Apparent Power Factor (aPF) Average Current (Amps) Individual Phases Displacement Power Factor (dPF) Average Line to Line Voltage (Volts) Individual Phases Current (Amps) Average Line to Neutral Voltage (Volts) Individual Phases Line to Neutral Voltages (Volts) Multiple Meters External Data Synchronization Individual Phases Line to Line Voltages (Volts)
DISPLAY FOR LOCAL MONITORING AND TROUBLESHOOTING
CONFIGURE MODBUS ADDRESSES
SERIAL/RS-485 CON­FIGURE BACnet MS/TP OR MODBUS RTU
USB PORT FOR EASY PC TO METER SETUP
CT CONNECTORS, FIELD
SELECTABLE TO USE ROGOWSKI
COILS OR STANDARD CTs
BUTTON TO SCROLL THROUGH MENU FUNCTIONS
PHASE VERIFICATION LEDs ­VERIFY PROPER CT INSTALLATION
VOLTAGE CONNECTIONS BROADBAND POWER SUPPLY 80-630 Volts
DINRAIL CLIP FOR VERSATILE
MOUNTING
ETHERNET CONFIGURE BACnet IP/MODBUS TCP
Phone: 978.263.1400 || Fax: 978.264. 0292 || www.setra.com
Setra Systems, Inc.
SAVE MONEY - SAVE TIME - SIMPLIFY YOUR JOB
Loading...