Power Battalion 48
Networked Power Meter
The Power Battalion 48 is a multi-circuit, revenue grade
power meter designed to signicantly reduce installation
time and cost per metering point. The Power Battalion 48
can be used with standard CTs, 1 Volt output or less, or with
Rogowski style CTs to monitor any combination of up to
16 three-phase or 48 single-phase loads. The versatility
of the device allows monitoring of two separate voltages
and transformers on same meter simultaneously. The
Setra power meter provides ANSI C12.20 accuracy on all
circuits being metered.
Easy Installation and Conguration
The Power Battalion 48 is line powered with 90-600 volts,
eliminating the need to choose a separate model number
for single or three phase circuits and ensuring the correct
part numbers are ordered. The Power Battalion 48 can be
congured with a web browser or direct USB connection
prior to installation, signicantly reducing labor costs,
maximizing safety and eliminating the need for personal
protective equipment. The initial set-up of the meter can
be done from a lap top using the free Headstart software
which also allows for cloning of the set-up parameters
for multiple meters. The multi-colored backlit display
ensure that the CTs are properly phased the rst time,
eliminating the hassle and expense of having to return
to the job site.
CT Flexibility
The Power Battalion 48 provides the option to choose
between standard split core CTs, existing current
transformers or the Setra Patrol Flex CTs. Power Battalion
48’s interchangeable CT conguration on the browser
drop down menu allows for exibility at the job site or
when making last minute changes. Setra Patrol Flex CTs
are industry best 0.5% revenue grade accuracy when
used in conjunction with the Battalion.
5
YEAR
n
Phase-CheckVericationShownonDisplaytoConrm
ProperCTOrientation
n
FieldSelectableBACnet/Modbus(4-in-1)
n
Back-litPushButtonDisplay
Power Battalion Features:
• Dual voltage; Monitor two separate voltages and transformers on the
same meter simultaneously
• Displays total harmonic distortion, waveform capture,
phasor plot in real time
• 4-in-1 eld selectable network communications:
BACnet IP, MS/TP, Modbus TCP/RTU
• 1.8 KHZ processor; updates data every second
• Phase-Check verication shown on display
• Pluggable terminal blocks for easy wiring and verication
• Backlit display
• UL listed (enclosure option); UL recognized (mounting plate option)
• NEMA 1 enclosure or circuit board only models available
• Phase loss alarm relay
• 125 communication object points/registers per meter to choose from
• On-board 12 V power supply for external sensors
• 5 year warranty, BTL certied
Applications:
• High Density Electrical Distribution Panels
• Demand Side Management
• Preventative Maintenance
• Retail Store Lighting Loads
• LEED Projects
• Chiller Optimization
Phone: 800-257-3872 • Fax: 978-264-0292 • setra.com © Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc.
Power Battalion 48
Networked Power Meter
ORDERING INFORMATION
S P B 84
Model Enclosure Display Options
SPB48= Setra Power Battalion 48 C Enclosure D Display N None
P Mounting Plate N No Display
SPECIFICATIONS
N
900900-G USB Communication Cable, Type A to B
900901-G USB Flash Drive, HeadStart Software
SPP-ACC-LEADS-208 Voltage Leads 208 VAC
SPP-ACC-LEADS-480 Voltage Leads 480 VAC
SPP-ACC-FUSE-208 Fuse Leads 208 VAC
SPP-ACC-FUSE-480 Fuse Leads 480 VAc
ACCESSORIES
Technical Communications
Service Type Single Phase, Split Phase, Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta) Hardware RS-485, Ethernet, and USB (for conguration only)
Power From L1 Phase to L2 Phase, 90-600 VAC RMS CAT III 50/60Hz, 500mA AC Max Supported Protocols Modbus (using SunSpec IEEE-754 single precision oating point model), or BACnet
AC Protection 0.5A Fuse 200kA interrupt capacity Max Distance 1,200 meters with Data Range of 100k bits/second or less
Power Out Unregulated 12 VDC output, 200 mA, self-resetting fuse. Supported Baud Rates 9600, 19200, 38400, 57600, 76800, 115200 baud
Voltage Channels 80-346 Volts AC Lint-to-Neutral, 600V Line-to-Line, CAT III. Two voltage reference inputs Data Bits 8
Current Channels 48 channels, 0.525 VAC max, 333 mV CTs, 0-4,000+ Amps depending on CT Parity None, Even, Odd
Maximum Current Input
Measurement Type True RMS using high-speed digital signal processing (DSP) with continuous sampling Data Formats Modbus, BACnet MS/TP, Modbus TCP or BACnet IP
Line Frequency 50/60 Hz
Waveform Sampling 1.8 kHz Wire Connections 12-22 AWG
Parameter Update Rate 1 second Mounting Panel Mount/Enclosure
Measurements
Accuracy 0.2% ANSI C12.20-2010 Class 0.2 Mounting Plate Available with Circuit Board Only model
Resolution Values reported in IEEE-754 single precision oating point format (32 bit) Operating Temperature1-20° to +60°C (-4° to 140°F)
Display 4-line display, tri-color backlight (PhaseChekTM) Humidity 5% to 95% non-condensing
Pulse Output
Certications
UL Recognized Mounting plate version
UL Listed Indoor enclosure version Operating System Windows® 10, Windows® 8, Windows® 7
CE Compliant Yes Communications Ethernet or USB. One free USB port required on PC
ANSI C12.20 Class 0.2 NIST Traceable Calibration Security 2 password levels
1
-20°C LCD display could be illegible. Meter voltage @ -20°C must exceed 100 VAC to power the meter.
150% of current transducer rating (mV CTs) to maintain accuracy. Measure up to 4000 A
with Rogowski Coil CTs
Volts, Amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, Import (Received)
kWh, Export (Delivered) kWh, Net kWh, Import (Received) kVAh, Export (Delivered)
kVAh, Net kVAh, Import (Received) kVARh, Export (Delivered) kVARh, Net kVARh, THD,
Theta, Frequency. All parameters for each phase and system total.
Open Collector, 5mA max current,
40V max open voltage.
Stop Bit 2,1
Mechanical
PCBA Mounting 0.5” Standos #6 (Quantity 6)(user supplied)
High Voltage Cover IP40
Enclosure ABS Plastic, 94-V0 ammability rating
Enclosure Dimension
PCBA Dimensions
(L) 26.5cm x (W) 24.8cm x (H) 7.6CM
(L) 14.25” x (W) 9.75” x (H) 3.0”
(L) 21.6cm x (W) 21.6cm x (H) 6.4cm
(L) 8.5” x (W) 8.5” x (H) 2.5”
Headstart Software
Specications subject to change without notice.
MODBUS REGISTER/BACNET
OBJECT DESCRIPTION LIST
System True Energy (kWh) Individual Phase to Phase Voltages Average Current (Amps)
Instantaneous Total True Power (kW) Line Frequency (Hz) Average Line to Line Voltage (Volts)
Peak Demand (Adjustable Window) (kW) Individual Phases True Energy (kWh) Average Line to Neutral Voltage (Volts)
Maximum Instantaneous Power (kW) Individual Phases True Power (kW) Multiple Meters External Data Synchronization
System Reactive Energy (kVARh) Individual Phases Reactive Energy (kVARh) Individual Phases Displacement Power Factor (dPF)
System Apparent Energy (kVAh) Individual Phases Reactive Power (kVAR) Individual Phases Current (Amps)
System Apparent Power (kVA) Individual Phases Apparent Energy (kVAh) Individual Phases Line to Neutral Voltages (Volts)
System Displacement Power Factor (dPF) Individual Phases Apparent Power (kVA) Individual Phases Line to Line Voltages (Volts)
System Apparent Power Factor (aPF) Individual Phases Apparent Power Factor (aPF) Refer to Operating Manual For Complete List
Phone: 800-257-3872 • Fax: 978-264-0292 • setra.com © Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc.
SSP-SPB48 Rev. A 11/17