Setra Networked Specifications

Power Meter
Networked Multi-Load Power Meter
Features
The Power Meter from Setra is a networked revenue grade power meter built on a versatile and powerful platform designed to meet the high demands for any submetering application. Available in a 3, 12 or 48
load congurations, the meter enclosure & intuitive web portal interface signicantly reduce installation time and cost per metering point. The Power Meter 12 & 48 load meters come standard with dual voltage inputs, and all versions are eld congurable for use of standard or Rogowski
style current transformers, enabling safe and accurate measurement of both low and high amperage services.
Easy installation and conguration
Every Power Meter was painstakingly designed to simplify the installation
process on the job site or at the ofce. The enclosure of the power meter
is its own NEMA 1 rated electrical enclosure, eliminating the need to purchase an electrical panel for the job, saving both time and money.
The eld rotatable display allows the installer to put the conduit holes exactly where they need to be for any mounting conguration, even in
the tightest locations in the electrical room. Setra’s on-board web portal
interface allows for safe pre-conguration of all parameters before, during,
or after the meter has been installed. The web portal not only gives the
user the ability to pre-congure the meter, but also offers the ability to
access powerful analytics and installation tools directly through the USB or communication connection.
Monitor 3, 12, or 48 loads on any combination of single and/or three
phase systems
• Monitor voltage, current, power, energy, and many other parameters
Rotatable display to simplify installation
Line-powered, 80-600V phase-to-phase power supply with 200kAIC
internal fuse
ANSI C12.20-2015 Class 0.2 revenue-grade metering
• UL 94-V0 rated enclosure
Can be used on both BACnet and Modbus protocols and features 2
pulse inputs one pulse output ports, plus serial and Ethernet
Use both conventional and Rogowski coil CTs interchangeably
• 4-line Display shows real-time information about meter
conguration and data
CT polarity correction ensures proper CT installation
• UL listed
CE & RoHS compliant
• Floating point, IEEE-754 data format allows for bidirectional
monitoring
Applications
• Data centers
• Tenant submetering
• Bi-directional metering
Real-time power metering in commercial, retail, and industrial
Patent pending
The Setra Systems name and logo are registered trademarks of Setra Systems, Inc.
BACnet® is a registered trademark of American Society of heating, refrigeration, and air-conditioning
© Setra Systems, Inc. All rights reserved.
BTL® is a registered trademark of BACnet International.
engineers (ASHRAE).
Field selectable communication (5 in1)
Each Power Meter comes standard with eld selectable BACnet and
Modbus communication protocols. The communications interface is
through either an EIA-485 serial connection (BACnet MS/TP or Modbus RTU) or over Ethernet (BACnet/IP or Modbus TCP). Along with these
advanced network communication protocols, the Power Meter offers one
congurable pulse output and two congurable pulse inputs, enabling
more data collection at the meter.
Multi-load monitoring & data logging
Multi-load monitoring provides the granularity needed to drive energy savings and manage usage at a load level. Leveraging the dual-voltage
inputs on the 12 & 48 models the user can measure any combination of single, dual or three phase service up to the amount of CT inputs on the
meter. Every version of the Power Meter comes standard with data logging capabilities, allowing the user to gain access to the data for up to 62 days,
using the web portal software.
Safe access without PPE
All aspects of the Power Meter enclosure and interface were designed to protect the user from harm. Setra’s NFPA70E compliant USB interface
allows the user to safely make conguration changes or access data
without having to wear PPE or shut down the service to panel. All Power
Meters come standard with a 200 KAIC fuse, making it one of the highest
rated devices on an electrical system and exceeding most requirements to make it the safest meter on the market.
800.257.3872 | www.setra.com
Power Meter | Networked Multi-Circuit Power Meter
Specications
General
Service type
Power
AC protection 0.5A fuse 200 kA interrupt capacity
Voltage Inputs
Current Inputs
Maximum current input
Measurement type
Line frequency
Waveform sampling 12 kS/s
Parameter update rate 1 second
Measurements
Accuracy 0.2% ANSI C12.20-2015 Class 0.2
Real-time clock backup
Display
Alarm replay output User congurable SPDT relay (30VDC/VAC,2Arms)
Pulse inputs/output
Single phase, split phase, three phase-four wire (WYE),
Self powered from Vin1 L1 and L2, 80-600 VAC RMS CAT III
80-347 VAC line-to-neutral, 80-600 VAC line-to-line, CAT III
Power Meter 12 & 48 have two sets voltage inputs
Split/ solid core CT: Congurable up to 2 volts
150% of CT rating (mV CTs) to maintain accuracy.
Measure up to 6,000 A with Patrol Flex Rogowski coils
Volts, Amps, kW, kVAR, kVA, aPF, dPF, kW peak demand,
Import (Received) kWh, Export (Delivered) kWh, Net kWh,
Import (Received) kVAh, Export (Delivered)kVAh, Net kVAh,
Import (Received) kVARh, Export (Delivered) kVARh, Net
All parameters for each phase and element load total
5 year (by user replaceable coin battery)
Two isolated 30Vdc input max. One isolated output with
Max pulse rate 20 Hz Min pulse width 20 ms.
three phase-three wire (Delta)
50/60 Hz, 5W max
3, 12, or 48 CT inputs
Rogowski coil: Patrol Flex
True RMS up to 50
One to three phase AC system
kVARh, THD, Phase angle, Frequency.
4-line 20 characters backlit LCD
th
Harmonic 60Hz
Measurement taken L1-N.
One green/red status LED
open collector 30Vdc max.
50/60 Hz
Web portal
Web browser Support all major browsers
Communications
Security
10/100 Mbps Ethernet, or Ethernet over USB. Ethernet over
USB requires one USB 2.0 port and Ethernet over USB drivers.
PIN protection
Communications
Hardware Isolated EIA-485, Ethernet, and USB
Supported protocols Modbus RTU, BACnet MS/TP, Modbus TCP or BACnet/IP
Max. communication length
Communication rate (baud)
Modbus RTU data bits 8
Modbus RTU parity None
Modbus RTU stop bits 1
1,000m for EIA-485, 100m for Ethernet
9600, 19200, 38400 (default), 57600, 76800
Mechanical
12-28 AWG 600 VAC voltage input screw terminals,
Wire connections
Mounting
Temperature
Humidity 5% to 95% non-condensing
Enclosure
Main enclosure IP20 High voltage area IP40
Enclosure dimensions
12-24 AWG 600 VAC CT input screw terminals,
voltage connection must be #14 AWG or larger wires &
DIN rail or 4-point screw mount for 3/12 channel. 48
Connections: 3/4” EMT conduit ports for power. 3/4”
(3 & 12 Load)
14-20 AWG 300V I/O screw terminals,
600 VAC rated to meet safety requirement
channel uses 5 point mounting holes only.
Operating -4° to 140°F (-20° to 60°C)
Storage -22° to 176°F(-30° to 80°C)
ABS/Polycarbonate, 94-V0 flammability rating
EMT knock-outs for load lines (3/12 load)
1.0” knock-outs for load lines (48 load)
(48 Load)
(L) 7” x (W) 6.8” x (H) 3.8”
(L) 17.2” x (W) 10.8” x (H) 4.4”
Certications
UL listed
CE LVD (EN61010-1), EMCD (EN61326-1), RoHS
FCC FCC Part 15 class B
BACnet Device prole B-ASC Protocol-Rev 14
Certied to CSA Std C22.2 No. 61010-1 3rd Edition
Conforms to UL Std 61010-1 3rd Edition,
Applies to indoor enclosure,
NIST traceable calibration
Specications subject to change without notice.
Ordering information
Example part number: SPM12EDN
Power Meter, 12 loads, Ethernet & serial communication ports, with onboard display and no option.
[1]
[1]
Model
SPM Power Meter
© Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc. | www.setra.com | 800.257.3872
[2]
Loads
03 3 loads
12 12 loads
48 48 loads
[2] [3] [4] [5]
[3]
Communication
E Ethernet & serial
D Onboard display
[4] [5]
Display
N None
Option
Loading...
+ 2 hidden pages