MicroCal
Advanced Modular
Pressure Calibrator
The MicroCal™ automated pressure calibrator is used as a
stand-alone calibration standard for dierential and gauge
pressure sensors found in critical environments. Setra partnered with NASA to develop the industry’s quickest and most
stable pressure control for low range applications. The MicroCal™ combines precise pressure control with high accuracy
modular pressure references providing the quickest and most
accurate calibration solution available on the market today.
The MicroCal™ is an easy-to-use solution that signicantly improves labor productivity and eciency when compared to
the leading competitors, providing immediate ROI.
Modular Design to Cover Many Applications
The MicroCal™ utilizes modular pressure references, enabling
the user to select the most accurate reference for calibrating
the unit under test. Competitive calibrators often use xed
higher range reference sensors that do not allow for proper
calibration ratios at the low end of the pressure range. The
modular rechargeable battery oers further exibility to extend available calibration time beyond the standard 8 hours.
™
n Best-in-Class Pressure Generation
n Immediate ROI
n Increased Calibration Ratios
NASA Patented Technology
The MicroCal™ is designed to perform calibration checks on
installed sensors, pressure switches and gauges that monitor
critical applications. The on-board pressure generation system
allows for stable & accurate pressure to be applied to the unit
under test during calibration, while providing isolation from
process background disturbances. This NASA patented technology achieves 0.0002 “W.C./step resolution; when combined
with the high accuracy MCPM pressure module the MicroCal™
is the ultimate low-pressure calibration device.
Reduce Calibration Time
When the fast and stable pressure control is combined with
high accuracy reference modules and easy to use interface,
the MicroCal™ can reduce overall calibration time up to 80%.
This time savings provides almost immediate ROI based on the
number of calibrations performed annually.
7” Touchscreen With Intuitive User Interface
The easy to use 7” touchscreen interface, combined with an intuitive menu structure, provides the user with all the features
needed for verication and calibration of dierential pressure
instrumentation. The MicroCal™ oers the Expert System feature, which detects and automatically calibrates Setra’s Model
269 digital pressure transducer.
MicroCal™ Features:
• Modular Pressure References
• Up to 8 Hours of Battery Life
• Easy Stey-by-Step User Interface Process
• Built-In Leak Test Function
• Provides Accuracy & Stability Plots
• Pressure Generation & Monitoring Modes to Verify
System Performance
• True Low Range Dual Reference Pressure Sensors
With NIST Traceability
Calibration Capabilities:
• Analog Pressure Transducers
• Pressure Switches
• Analog Dial Gauges
Phone: 800-257-3872 • Fax: 978-264-0292 • setra.com © Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc.
MicroCal™
Advanced Modular Pressure Calibrator
ORDERING INFORMATION
M C A L
Model Pressure Control Range Electro-Pneumatic Interface Options
MCAL = MicroCal
™
L Low- up to 0-30” W.C N Std. user interface with 6’ tubing
M Std. user interface with 12’ tubing
E Expert system interface with 6’ cable and tubing
L Expert system interface with 12’ cable and tubing
N None
L LEMO Connector for Remote Digital Sensor
Ordering Example: MCALLMN = MicroCal® , Range
30”W.C., Std. user interface with 12’ tubing.
REFERENCE MODULES
M C P M
Model Range
MCPM = MicroCal™ Pressure Modules “W. C Pascal
Unidirectional
0R5WD10 to 0.5 100LD10 to 100
001WD20 to 1 250LD20 to 250
005WD20 to 5 500LD20 to 500
2R5WD20 to 2.5 10CLD20 to 1000
015WD20 to 15 35CLD20 to 3500
Bidirectional
R25WB1±0.25 050LB1±50
0R5WB1±0.5 100LB1±100
001WB2±1 250LB2±250
2R5WB2±2.5 500LB2±500
005WB2±5 10CLB2±1000
015WB2±15 35CLB2±3500
Ordering Example: MCPMR25WB=MicroCal™ Pressure Module, Range ±0.25”W.C.
1
Low Range
2
High Range
ACCESSORIES
869783-G Spare Battery
869974-G Desktop Charger
869923 Accessory Kit (Screwdriver, Silicon Tube, Misc. Fittings)
869920 Harness Cable End Ass’y, 2-Wire
869904-10 2-Wire Electro-Pneumatic Harness: 10 ft.
869921 Harness Cable End Ass’y, 4-Wire
869905-10 4-Wire Electro-pneumatic Harness: 10 ft.
GENERAL SPECIFICATIONS
Measurement Uncertainty (1 YR)
Pressure High Range: Max Range ≥ 1”W.C.: ±0.1% Reading ±0.016% FS
Voltage
Current
Low Range: Max Range < 1”W.C.: ±0.12% Reading ±0.028% FS
±0.015% Reading ±0.002V
±0.015% Reading ±0.002 mA
Physical
Operating Temperature 50o to 95oF (10o to 35oC)
Storage Temperature 32
Power Requirements 24 VDC (110/220V Power Adapter Included)
Battery (included) Li-ion, 6.75 AH, Recharge Time < 3 hours
Case Dimensions 18.6” x 14.7” x 7.1”
Weight 18-22 lbs.
Control
Controlled Pressure Stability 0.0002” W.C.
Minimum Controlled Pressure 0.00005” W.C.
Temperature Eect (Outside Operating Temperature)
Zero None, Zero Tare
Span Additional ±0.005% FS/
General
Engineering Units Field Selectable (20 Options)
Warm up 20 Minutes
Communications RS232
Display 7” Touchscreen
Pressure Connections Plug-In O-Ring Quick Connects
Electrical Connections Banana Plug Jacks
Specications subject to change.
1
1 year specication is instrumental uncertainty that includes linearity, hysteresis, repeatability, resolution reference uncertainty, 1 year stability and span error. The uncertainties are
provided at 95% condence, k=2, normally distributed.
1
o
to 160oF (0o to 71oC)
o
F
Phone: 800-257-3872 • Fax: 978-264-0292 • setra.com © Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc.
SSP MCAL 8/2015 Rev B