Setra FLEX Data sheet

Environmental Monitor
• Supports 3 rooms, 6 parameters each
• 7” Projected capacitive touch screen
• BACnet/IP & BACnet MS/TP
• Flush mount to wall
• Mounts in standard electrical boxes
• Full touch response with medical gloves
• No programing required
4 Inputs & 2 outputs on-board
• On-board or external pressure transducer
High accuracy 0.25% sensor standard
• Monitor and control pressure, temperature, humidity,
air change rate, and 2 user-dened parameters
4 Customizable room proles
2 Levels of password security
User-dened on-screen text and icons
Conguration options help reduce nuisance alarms
50mm Wall depth when sensor is mounted remotely
• Cloning features reduces time required for multi-unit installation
• Remote duplicate display shows parameters inside
and outside of rooms
The Setra FLEX™ provides a flexible room environmental control and monitoring solution in a simple-to-use package. An attractive flush-mount faceplate is complemented by an intuitive graphical display to meet any architectural requirement. The unit supports 3 rooms, monitoring up to 6 parameters for each room. An optional differential pressure sensor can be either factory-installed in the unit or ordered separately and installed above the ceiling. Integration with building automation systems is made easy through either BACnet/IP or BACnet MS/TP network protocols.
Modular design
A modular hardware design enables the FLEX monitor to t in various
wall thickness found around the globe. For applications which require the
monitor to t in wall depths less than 50mm, the FLEX can be ordered with
an external pressure sensor. When mounting in a three gang electrical box,
the FLEX can be ordered with an integrated on-board sensor. Sufcient on-
board I/O provides connectivity for most common equipment and sensor applications. If additional connections are required, or if more advanced HVAC applications demand it, FLEX can work directly with a third party
controller over BACnet. A high accuracy 0.25% differential pressure
transducer is used in all pressure sensing options. A projected capacitive touch screen provides swipe functionality and allows for use with medical gloves. The faceplate is attached to the unit body, enabling both tamper resistant operation and easy opening for pressure calibration.
Setra FLEX-RM and FLEX-RC
FLEX software is designed to suit any application, with the ability to support up to 3 rooms. FLEX-RM (Room Monitor) provides monitoring only, for those applications where no control from the touch screen is needed. FLEX-RC (Room Control) offers monitoring, plus PI loop or network control of VAV boxes, venturi valves, or hydronic reheat valves. Software is pre-
installed, with conguration and network integration done using simple
setup screens. There is no programming required. When completed,
conguration settings on one unit can be cloned to other devices using a
standard USB thumb drive, thereby shortening commissioning time. Units
can also be congured remotely over a BACnet network.
The FLEX monitor is both a controller and monitor, with audible and visual alarming on all room environmental parameters. The FLEX monitor enables users to save energy by choosing from two PI control loops and two monitoring sets for any of four room modes, such as occupied and unoccupied.
The Setra Systems name and logo are registered trademarks of Setra Systems, Inc.
© Setra Systems, Inc. All rights reserved.
800.257.3872 | www.setra.com
Setra FLEX
91.4mm
3.60”
154.2mm
6.00”
5.18”
154.2mm
6.00”
18.3mm
49.1mm
1.93”
235mm
9.25”
131.5mm
5.18”
70.9mm
2.79”
Shown with no transducer attached
70.9mm
2.79”
TM
| Environmental Monitor
Software featuresSpecications
Physical description
Dimensions
Mounting
Triple-gang, double deep electrical box. RACO 697,
(215.0mm x 160.0mm x 16.51mm)
Case Fire-retardant plastic UL94 V-0
Weight 2 lbs
Display
7” Projected Capacitive (PCAP) multi-touch. 800 x 480
pixels. Usable with medical gloves.
Display brightness 1-7
USB port
Micro-USB port for conguration cloning between units
Audible alarm
9.25” W x 6.3” H x 0.65”D
Appleton M3-350, or equivalent
and software upgrades.
Communications
Protocols (BACnet objects can be found at setra.com) BTL- compliant
BACnet/IP using IPv4, Ethernet CAT5 cables with RJ45
BACnet MS/TP up to 76.8 kbps, 3-conductor, twisted, shielded 16-24 AWG cable
Electrical
Power 24 VAC (18-30 VAC operational), 50-60 HZ
Power draw 13 W max, 10 W typical
Wire
2 or 3-conductor (depending on application)
stranded unshielded twisted pair, 16-24 AWG
Connections Removable Terminal Blocks
Regulatory compliance
CSA, CE, RoHS, WEEE
Environmental data
Operating temp. °F (°C) 32 to 120 (0 to 50)
Storage temp. °F (°C) -40 to 185 (-40 to 85)
Operating humidity 5 to 95% RH (non-condensing)
Ingress Protection (IP) rating IP54
Chemical resistance
Exposed surfaces are chemically resistant to vaporized hydrogen peroxide (VHP), formaldehyde, chlorine dioxide (clidox), perchloric acid, sodium hypochlorite 3-6% (bleach), quaternary ammonium 7% in 1:128 tap water (ammonia).
Performance
Accuracy RSS ±0.25%
Non-linearity (BFSL) ±0.24%
Hysteresis ±0.05%
Non-repeatability ±0.05%
Dual piezo
Home screen
Rooms supported (3)
Parameters per room (6)
Room proles (4)
Pressure modes (3) Positive, Negative, Neutral
Background colors (5) Green, yellow, blue, red, orange for room condition.
Text (2) User dened lines text that describe room condition.
Icons (32)
Control
Carousel display to show up to 3 rooms, with monitor and
Badges display pressure, temperature, humidity, air
change rate, and 2 user-dened parameters. Each
Dene proles for room environmental control and
monitoring. User-dened text. Used for modes such as
occupied, unoccupied, cleaning, or decontamination.
capable of monitor or control.
All information available over BACnet.
Choose from a palette of icons to represent room
Control loops assignable per device. PI control loop for
on-board analog outputs. User-dened set point limits.
All information available over BACnet.
control for each.
condition.
Alarming
Parameters per room (6)
Visual Green = normal, Red = alarm, Yellow = warning
Audible Dual buzzers
Disable One-touch all alarms disable function.
Silence Selectable 0 - ∞ seconds
Delay Selectable 0 - 9999 seconds
Latch
Remote
Visual and audible alarms for pressure, temperature,
humidity, air change rate, and 2 user-dened parameters.
Alarm option to hold alarm state until
Remote annunciation to dedicated unit (p/n SRAN)
manually reset by operator.
or to multi-unit room monitor.
Dimensions
91.4mm
3.60”
154.2mm
6.00”
235mm
9.25”
.72”
Wall seal
66.2mm
2.61”
Shown with in-wall transducer attached
Span setting tol. ±0.5% Rdg
Zero/span shift % FS ± 0.03% PSI (±0.05% FS)
Overpressure ±1 PSI (15” WC for ≤0.10” WC FS)
Pressure media Air or non-conductive, non-explosive gases
Pressure ttings 3/16” barbed ttings
Altitude 6562 ft. (2000 m) max.
Position Housing to be 90° in reference to level surface, ±5°
Specications subject to change without notice.
© Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc. | www.setra.com | 800.257.3872
160mm
6.30”
70.9mm
131.5mm
2.79”
49.1mm
1.93”
Shown with no transducer attached