Setra 512 Data sheet

Model 512
Industrial OEM Pressure Transducer
Gauge and Compound Pressure
Applications
General Purpose
Off-Highway Vehicles
Equipment
Hydraulic Systems
Pumps and Compressors
Industrial Engines
Process Systems
Benefits
Superior Stability
Avoids Down Time
Insensitive to Pressure
Spikes
±0.5% FS Accuracy
IP65 and IP67 Rated
etra System’s Model 512 OEM pressure
transducer is designed to withstand pressure spikes, shock, and vibration
S
caused by the harsh physical and environmental conditions of industrial applications.
The Model 512’s CVD strain gauge design is resistant to aging and virtually insensitive to thermal transients and pressure cycling. The stability of this technology assures the user of high reliability with less than 0.2% drift per year.
This units exceptional proof pressure specification is 4 x full scale with less than a
1.0% zero shift.
The Model 512 offers 0.5% FS accuracy, compensated temperature range of -5°F to +180°F (-20°C to 80°C), and gauge or compound pressure ranges from -14.7 psi up to 6000 psi.
The Model 512’s modular design is offered in a wide choice of voltage or current outputs over almost any pressure range, and a variety of pressure and electrical connections, enabling this unit to be custom configured for your OEM application.
Depending upon the electrical connection selected, when coupled with the Model 512 enclosure, which is fabricated in 316 SS/17-4 PH SS, this unit is rated for IP65 or IP67 operation.
All wetted parts are constructed of corrosion­resistant 17-4 PH stainless steel, which makes this unit ideal for use with corrosive media.
Principle of Operation
Using the well proven Wheatstone Bridge principle, a chemical vapor is deposited in thin layers of silicon and silicon dioxide onto a stainless steel sensor to form a very sensitive and accurate polysilicon strain gauge. The elements of the strain gauge are fused together at the atomic level, assuring the strength and integrity of the bond, which exceeds the adhesives used in common bonded strain gauge pressure sensors. A custom designed ASIC performs signal amplification and temperature compensation. This technology offers the user the option of configurable output and pressure ranges, sets the zero and span tolerance, and ensures interchangeability from unit to unit.
High Shock Resistance
Meets
When it comes to a product to rely on - choose the Model 512. When it comes to a company to trust - choose Setra.
CECE
CE Conformance
CECE
Standards
ISO
9001: 2000
Certified
Visit Setra On-line:
http://www.setra.com
159 Swanson Road, Boxborough, MA 01719/Telephone: 978-263-1400/Fax: 978-264-0292
800-257-3872
Model 512 Specifications
Performance Data
Accuracy RSS
Thermal Effects Compensated Range °F (°C) -5 to +180 (-20 to +80) Zero Shift %FS/100°F (100°C) 1.0 (2.0) Span Shift %FS/100°F (100°C) 1.0 (2.0)
Response Time 0.5 ms
Long-Term Stability 0.2% FS/year
Proof Pressure 4 x FS (<1% Zero Shift)
Burst Pressure >35 x FS <= 60 Psi (4 Bar)
*RSS of Non-Linearity, Non-Repeatability and Hysteresis. **Units calibrated at nominal 70°F. Maximum thermal error computed from this datum.
*
(at constant temp) ±0.5% Full Scale
**
>20 X FS <=600 Psi (40 Bar)
>5 X FS <= 6000 Psi (400 Bar)
Physical Description
Case 316 Stainless Steel,
17-4 Stainless Steel
Ratings IP65 for Elec Codes E1 and N1
IP67 for Elec Code NA
Wetted Parts 17-4 PH Stainless Steel
Outline Drawings
Physical Description (Cont’d)
Electrical Connection 4-Pin MINI DIN Connector
IP67 Weatherproof Cable Gland
Max.)
IP65 Cable Pressure Fitting See Ordering Information Below Weight 3.5oz (100g)
Environmental Data
Temperature Operating* °F (°C) for/ Elec Code E1 -40 to +260 (-40 to +125) for/ Elec. Code N1 -5 to +180 (-20 to +80) for/ Elec. Code NA -5 to +125 (-20 to +50) Storage °F (°C) for/ Elec Code E1 -40 to +260 (-40 to +125) for/ Elec. Code N1 -5 to +180 (-20 to +80) for/ Elec. Code NA -5 to +125 (-20 to +50) Vibration 70g Peak to Peak Sinusoidal, 5 to 5000 Hz
(Random Vibration: 20 to 200 Hz~ 20g
Peak per MIL STD-810E Method 514.4) Shock 20g, 11ms, per MIL-STD-810E
Method 516.4 Procedure 1
*Operating/Storage temperature limits of the connector only.
1.07 27
(3ft Depth,
Electrical Data (Voltage)
Circuit 3 -Wire (Exc, Out, Com) Excitation 1.5 VDC Above Span to 35 VDC @ 6mA**
*
Output
0 to 5VDC, 0 to 10VDC,
0.5 to 5.5 VDC, 1 to 5 VDC, 1 to 6 VDC, 1 to 11 VDC
*Zero output is factory set to <1.0% of Full Scale. *Span output is factory set to <1.0% of Full Scale.
**Temperatures >100°C/212°F supply is limited to 24 VDC.
Electrical Data (Current)
Circuit 2-Wire
*
Output
4 to 20 mA Loop Supply Voltage 24 VDC, (7-35 VDC)** Maximum Loop Resistance (Vs-7) x 50 ohms
*Zero output factory set to within ±0.16 mA. *Span output factory set to within ±0.16 mA.
**Temperatures >100°C/212°F supply is limited to 24 VDC.
Pressure Media
Liquids or gases compatible with 17-4 PH Stainless Steel.*
*Note: Hydrogen not recommended for use with 17-4 PH Stainless Steel.
Specifications subject to change without notice.
1.07 27
0.87 22
Shown w/10-4 Bayonet Connector and 1/4-18 NPT Pressure
.Example: Part No 5121030PG1M11E1H - For a Model 512 Pressure Transducer, 30 PSI, Gauge Pressure, 1/8-27 NPT Male Pressure Fitting, 4-20 mA Output, 4-Pin Mini Din Connector, 0.5% Accuracy
5 1 2 1
Model
512 = 5121
While we provide application assistance on all Setra products, both personally and through our literature, it is the customer’s responsibility to determine the suitability of the product in the application.
015P = 15 PSI 001B = 1 BAR 030P = 30 PSI 0R6B = 1.6 BAR 060P = 60 PSI 2R5B = 2.5 BAR 100P = 100 PSI 004B = 4 BAR 150P = 150 PSI 006B = 6 BAR 200P = 200 PSI 010B = 10 BAR 300P = 300 PSI 016B = 16 BAR 500P = 500 PSI 025B = 25 BAR 600P = 600 PSI 040B = 40 BAR 10CP = 1000 PSI 060B = 60 BAR 15CP = 1500 PSI 100B = 100 BAR 20CP = 2000 PSI 160B = 160 BAR 30CP = 3000 PSI 250B = 250 BAR 40CP = 4000 PSI 400B = 400 BAR 50CP = 5000 PSI 60CP = 6000 PSI 000P = -14.7 to 0 PSI 015P = -14.7 to 15 PSI 045P = -14.7 to 45 PSIG 135P = -14.7 to 135 PSI 185P = -14.7 to 185 PSI 285P = -14.7 to 285 PSI
Range
2.43 62
0.79 20
1.37 35
Shown w/IP67 Weatherproof Cable and 7/16-20 UNF Male Sae #4 Pressure Fitting
ORDERING INFORMATION
Code all blocks in table.
Pressure G = Gauge C = Compound
Pressure Fitting
1M = 1/8-27 NPT Male 2M = 1/4-18 NPT Male SM = 1/4-NPT Male w/
Snubber
2F = 1/4-18 NPT Female
4M = 1/2-14 NPT Male
J7 = 7/16 -20 UNF Male
SAE #4 (J1926-2)
J9 = 9/16-18 UNF Male
SAE #6 (J1926-2)
Output 11 = 4-20mA 2B = 0-5 VDC 2C = 0 -10 VDC 24 = 0.5 - 5.5 VDC 27 = 1 - 5 VDC 28 = 1 - 6 VDC 2R = 1-11 VDC
Please contact factory for configurations not shown.
159 Swanson Road, Boxborough, MA 01719/Tel: 978-263-1400;
Toll Free: 800-257-3872; Fax: 978-264-0292; Email: sales@setra.com
Elec. Termination E1 = 4-Pin MINI DIN
Connector w/o Mate
NA = IP67 Weatherproof
Cable Gland
N1= IP65 Cable
*Note: Intrinsically safe transducers are available with amplified outputs only. (ETL., entity approved for Class 1 Division 1, Groups C & D, hazardous areas; Class 1 Divisions 1 and 2, Groups C & D for electrical termination code E1 and ?.
2.43 62
H
Accuracy
H = 0.5% FS
0.75 19
in
mm
Option A = Intrinsic Safe*
SSP512 Rev.B 09/26/06
Loading...