Absolute Pressure: 0-20 psia
The calibration of this product is NIST traceable.
Model 276
etra Systems has been a technology
The Model 276 is an extremely accurate
and stable transducer based on the proven
Setraceram
TM
sensing element. The glass
fused ceramic capacitive sensing capsule is
the heart of Setra's environmental pressure
transducers because of its inherent thermal
stability, low hysteresis and fundamentally
simple
design.
Another major feature of the 276 is Setra's
custom Application Specifi c Integrated Circuit
Setraceram
sensor to achieve long-term
stability and high accuracy, unmatched by
other manufacturers - even at a much higher
cost. The ASIC circuit allows the 276 to
operate with an excitation as low as 5 VDC
for rem ote
applications.
Barometric 600-1100 mb 20 PSIA
800-1100 mb 20 PSIA
Absolute 0-20 PSIA 30 PSIA
Type of Pressure Maximum
Type of Pressure Maximum
Pressure Range Pressure
Pressure Range Pressure
Applications
Environmental
Monitoring Systems
Weather Measurement Systems
Weather and
Environmental Data Logging
Barometric Presure Compensation for Internal Combustion Engine Performance
Cleanroom Barometric Pressure Compensation
Automotive Emissions Test Equipment
Features
Proven SETRACERAM Sensor
0.25% FS Accuracy
TM
S
Environmentally Rugged
<±0.25% FS, 6 Month
Stability
Compact Size (2" dia. x 1" )
Excellent Long-Term
Stability
Low Power Consumption (for Solar or Battery Power)
Fast Response
Meets CE Conformance
Standards
When it comes to a product to rely on - choose the Model 276. When it comes to a company to trust - choose Setra.
Visit Setra Online:
http://www.setra.com
800-257-3872
Accuracy RSS
(at constant temp) ±0.25% FS
Thermal Effects
Compensated Range °F(°C) +30 to +130 (0 to +55)
Zero Shift
1% FS
Span Shift
1% FS
output noise level
(0.0005% FS)
Time Constant 10 milliseconds to reach
90% fi nal output with step
function pressure input.
*RSS of Non-Linearity, Hysteresis and Non-Repeatability.
**FS = 300mb for 800-1100mb range; 500 for 600-1100mb range; and 20 PSI
for 0 to 20 PSIA.
***Units calibrated at nominal 70°F. Maximum thermal error computed from this
datum.
Temperature
Operating
°F (°C) 0 to +175 (-18 to +79)
Storage °F (°C) -65 to +250 (-55 to +121)
Vibration 2g from 5 Hz to 500 Hz
Shock 50g
(Operating, 1/2 sine 10 ms)
Acceleration 10g
*Operating temperature limits of the electronics only.
Pressure media temperatures may be considerably higher or lower.
Case Stainless Steel
Circuit 3-Wire
(Exc, Out, Com)
Specify One:
Output
Output
12 VDC (9.0 to 14.5) 0.1 to 5.1 VDC**
24 VDC (21.6 to 26.0) 0.1 to 5.1 VDC**
5 VDC (4.9 to 7.1) 0.5 to 4.5 VDC**
Output Impedance 5 ohms
Output Noise <200 microvolts RMS
(0 to 100 Hz)
*There are separate leads for +Exc, -Exc, +Out, -Out. The -Exc and -Out are
commoned internally. The shield is connected to the case. For best perfor-
mance, either the -Exc or -Out should be connected to the case. Unit is
calibrated at the factory with the -Exc connected to the case. The insulation
resistance between all signal leads tied together and case ground is 100
megohms minimum at 25 VDC.
**Zero and Full Scale Outputs are factory set to within ±0.25% Full Scale.
Model 276 Specifi cations
Toll Free: 800-257-3872; Fax: 978-264-0292; email: sales@setra.com
Specifi cations subject to change without notice.
alumina ceramics, gold and elastomer.
Available Options
Option #715 0.1% FS (RSS) Accuracy
Option #803-825 Up to 25 ft. of cable can be supplied.
Specify cable length when ordering (i.e.,
805 for 5 ft. cable). Consult factory for
cable lengths longer than 25 ft.
Option #839 1/8" NPT Pressure Connection
Calibration Certifi cate Option
Calibration Certifi cate Option
Option #901 11-point Calibration Certifi cate
While we provide application assistance on all Setra products, both
personally and through our literature, it is the customer's responsibility
to determine the suitability of the product in the application.
2 FT.
0.6 M
Cable
0.65
41.9
0.87
22.0
0.67
0.20
4.6
2.08
52.9
φ
φ
Tube Fitting
44.4
27.2
0.25
6.4
28.6
29.7
2.25
57.1
0.50
0.19 ±0.10
4.9 ±0.25
φ
φ
WITH BRACKET
SIDE VIEW
Outline Drawings
ORDERING INFORMATION
Loading...